SRP-F310/312
Rev. 1.01
BIXOLON
- 77 -
<Function 065> GS ( k pL pH cn fn n (fn=65)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
n
Hex
1D
28
6B
03
00
30
41
n
Decimal
29
40
107
3
0
48
65
n
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48, fn=65
0 ≤ n ≤ 30
Default:
n = 0
Description:
■
This command specifies the number of columns in the data area of PDF417.
•
When n=0, automatic processing is set
•
When n is not 0, the number of columns of the data area is set to n code word.
Remarks:
■
Settings of this command affect the processing of Functions 081.
■
With auto processing (n=0) specified, the maximum number of columns in the data area is set to 30 columns.
■
The following data is excluded from the number of columns:
•
Start and stop patterns
•
Indicator code word of left and right
■
With auto processing (n=0) specified, the number of columns is calculated using the following information.
•
Printing area when processing Functions 081
•
Module width (Function 067)
•
Option setting (Function 070)
■
The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
Differences:
None