SRP-F310/312
Rev. 1.01
BIXOLON
- 19 -
ESC %
Function:
Select/cancel user-defined character set
Code:
ASCII
ESC
%
n
Hex
1B
25
n
Decimal
27
37
n
Range:
0 ≤ n ≤ 255
Default:
n = 0
Description:
■
This command selects/deselects user-defined character set that is downloaded by user. To make it valid, the least
significant bit should be defined like following.
•
When n=0, the user-defined character set is deselected.
•
When n=1, the user-defined character set is selected.
Remarks:
■
The resident character set is enabled and used right after canceling the user defined character set.
Differences:
None