SRP-350/352III
Rev. 1.01
BIXOLON
- 104 -
•
Third byte (paper sensor information)
Bit
Off/On
Hex
Decimal
Function
0,1
Off
00
0
Paper near end sensor: paper adequate
On
03
3
Paper near end sensor: paper near end
2,3
Off
00
0
Paper end sensor: paper present
On
0C
12
Paper end sensor: no paper present
4
Off
00
0
Not used. Fixed to Off
5
Off
00
0
Not used. Fixed to Off
6
Off
00
0
Not used. Fixed to Off
7
Off
00
0
Not used. Fixed to Off
•
Fourth byte (paper sensor information)
Bit
Off/On
Hex
Decimal
Function
0
On
01
1
Not used. Fixed to On
1
On
02
2
Not used. Fixed to On
2
On
04
4
Not used. Fixed to On
3
On
08
8
Not used. Fixed to On
4
Off
00
0
Not used. Fixed to Off
5
Off
00
0
Not used. Fixed to Off
6
Off
00
0
Not used. Fixed to Off
7
Off
00
0
Not used. Fixed to Off
Differences:
None