Rev. 3.02
- 6 -
SRP-350
1-2 Servicing Precaution
WARNING 1: First read the Safety Precaution section of this manual. If some unforeseen
circumstance creates a conflict between the servicing and safety precautions,
always follow the safety precaution.
WARNING 2: An electrolytic capacitor installed with the wrong polarity might explode.
1. Always unplug the unit’s AC power cord from the AC power source or the Power Switch off before
attempting to:
(a) Remove or reinstall any component or assembly,
(b) Disconnect an electrical plug or connector,
(c) Connect a test component in parallel with an electrolytic capacitor.
2. Some components are raised above the printed circuit board for safety.
An insulation tube or tape is sometime used. The internal wiring is sometimes clamped to prevent contact
with thermally hot components. Reinstall all such elements to their original position.
3. After servicing, always check that the screws, components and wiring have been correctly reinstalled.
Make sure that the portion around the serviced part has not been damaged.
4. Check the insulation between the blades of the AC plug and accessible conductive parts.
(example: metal panels and input terminals).
5. Insulation Checking Procedure:
Disconnect the power cord from the AC source and turn the power switch ON. Connect an insulation
resistance meter (500V) to the blades of the AC plug. The insulation resistance between each blade of the
AC plug and accessible conductive parts (see above) should be greater than 1 mega-ohm.
6. Never defeat any of the B+ voltage interlock. Do not apply AC power to the unit (or any of its assemblies)
unless all solid-state heat sinks are correctly installed.
7. Always connect an instrument’s ground lead to the instrument chassis ground before connecting the
positive lead; always remove the instrument’s ground lead last.
Summary of Contents for SRP-350 PlusA
Page 1: ...Service Manual SRP 350 Thermal Printer Rev 3 02 http www bixolon com ...
Page 16: ...Rev 3 02 16 SRP 350 3 1 3 Feature Locations Figure 3 3 Feature Location ...
Page 28: ...Rev 3 02 28 SRP 350 4 Hardware 4 1 Wiring Diagram Figure 4 1 Board Wiring Diagram ...
Page 29: ...Rev 3 02 29 SRP 350 4 2 Block Diagram Figure 4 2 Block Diagram ...
Page 51: ...Rev 3 02 51 SRP 350 7 2 System Problem ...
Page 52: ...Rev 3 02 52 SRP 350 7 3 Panel PBA and Sensor Problem ...
Page 53: ...Rev 3 02 53 SRP 350 7 4 Thermal Printer Head and Feed Motor Problem ...
Page 54: ...Rev 3 02 54 SRP 350 7 5 Auto Cutter and Drawer Problem ...
Page 55: ...Rev 3 02 55 SRP 350 7 6 Dip S W and I F PBA Select Problem ...
Page 56: ...Rev 3 02 56 SRP 350 7 7 RS 232C Serial Communication Problem ...
Page 57: ...Rev 3 02 57 SRP 350 7 8 RS 485 Serial Communication Problem ...
Page 58: ...Rev 3 02 58 SRP 350 7 9 IEEE 1284 Parallel Communication Problem ...
Page 59: ...Rev 3 02 59 SRP 350 7 10 USB Communication Problem ...