3

KT-140-3

2 K C - 0 5 . 2 ( Y )   . .   2 C C - 4 . 2 ( Y )

4 Z - 5 . 2 ( Y )   . .   6 F - 5 0 . 2 ( Y ) ,   2 T . 2 ( Y )   . .   6 F . 2 ( Y )

B e f e s t i g u n g s b l e c h   ( P o s i t i o n   s i e h e   u n t e n )

F i x i n g   p l a t e   ( p o s i t i o n   s e e   a b o v e )

T ô l e   d e   f i x a t i o n   ( p o s i t i o n   v o i r   a u - d e s s o u s )

4 F C - 3 . 2 ( Y )   . .   4 C C - 6 . 2 ( Y )

4 0 0

19

6

36

5

21

3

3 1 5

11

6

4 0 0

29

7

12

6

10

8

2T.2(Y) .. 2N.2(Y)

6J-22.2(Y) .. 6F-50.2(Y)

6H.2(Y) .. 6F.2(Y)

4Z-5.2(Y) .. 4G-30.2(Y)

4T.2(Y) .. 4G.2(Y)

2EC-2.2(Y) .. 2CC-4.2(Y)

2KC-05.2(Y) .. 2FC-3.2(Y)

4FC-3.2(Y) .. 4CC-6.2(Y)

Abb. 1 Montageposition der Zusatzlüfter

Fig. 1 Mounting position of the additional

fans

Fig. 1 Position du montage des ventilateurs

additionnels

Summary of Contents for KT-140-3

Page 1: ...water cooled cylinder heads 2 Additional fan This cooling method can be used uni versally It offers a uniform cooling effect and its performance can be monitored easily by means of electrical protecti...

Page 2: ...Y 6F 2 Y Befestigungsbleche auf die Gewin debolzen stecken siehe Abb 1 Mit Federscheiben und Muttern befestigen L fter F e anschrau ben 2 KT 140 3 Alle Ventilatoren mit Wicklungsschutz Andere Spannun...

Page 3: ...t i o n p o s i t i o n v o i r a u d e s s o u s 4 F C 3 2 Y 4 C C 6 2 Y 4 0 0 1 9 6 3 6 5 2 1 3 3 1 5 1 1 6 4 0 0 2 9 7 1 2 6 1 0 8 2T 2 Y 2N 2 Y 6J 22 2 Y 6F 50 2 Y 6H 2 Y 6F 2 Y 4Z 5 2 Y 4G 30 2 Y...

Page 4: ...m tiques accessibles 3 5 3 3 0 4 4 0 0 5 7 4 4 3 2 4 6 7 4FC 3 2 Y 4CC 6 2 Y 3 1 5 4 0 5 3 4 4 2 1 7 2 6 8 4 7 5 4 3 2 3 9 8 3 0 0 3 1 5 2 5 3 4 9 7 2KC 05 2 Y 2FC 3 2 Y 2EC 2 2 Y 2CC 4 2 Y 4 0 0 4 3...

Page 5: ...Select the rotation direction so that the air flows directly onto the compressor 2 4 Mise en service Comparer les donn es de tension et de fr quence sur la plaque du moteur du ventilateur avec les don...

Page 6: ...e 3 Wassergek hlte Zylinderk pfe Option bei 4Z 5 2 Y 6F 50 2 Y 2T 2 Y 6F 2 Y III Y V Y Standard bei VI W Y VII W Y NH3 Ausf hrung der offenen Verdichter W2TA W6FA F r korrosives K hlwasser z B See was...

Page 7: ...ssor standstill When the compressor is off the cool ing water supply to the cylinder heads must be interrupted e g water regu lator solenoid valve to avoid conden sation of refrigerant back into the c...

Page 8: ...alten Subject to change Toutes modifications r s rv es 07 02 Bitzer K hlmaschinenbau GmbH Eschenbr nnlestr 15 71065 Sindelfingen Germany Tel 49 0 7031 932 0 Fax 49 0 7031 932 146 147 http www bitzer d...