T17+ Server Installation Guide     

4. Monitoring Your Server 

4. 

Monitoring Your server 

To check the operating status of your server:

 

1.

 

Click the status marked below. 

 

 

Note: The T17+ server is with automatic frequency. Firmware will stop running when the Temp 
(PCB) reaches to 75

 

or

 Temp(chips) reaches to 100

℃,

there will be an error message “Fatal Error:   

Temperature is too high!” shown in the bottom of kernel log page. 

 

2.

 

Monitor your server according to the descriptions in the following table: 

 

Option

 

Description

 

ASIC# 

Number of chips detected in the chain. 

Frequency 

ASIC frequency setting. 

GH/S(RT) 

Hash rate of each hash board (GH/s). 

Temp(PCB) 

Temperature of each hash board (°C). (Applied only to server with fixed frequency). 

Temp(Chip) 

Temperature of the chips on each hash board (°C). 

ASIC status 

One of the following statuses will appear: 

 

- indicates OK 

 

- indicates error 

 

- indicates dead 

 

 

 

 

Summary of Contents for ANTMINER T17+

Page 1: ...ations using Bitmain components To minimize the risks associated with customer products and applications customers should provide adequate design and operating safeguards Bitmain does not warrant or represent that any license either express or implied is granted under any Bitmain patent right copyright or other Bitmain intellectual property right relating to any combination machine or process in w...

Page 2: ...of Bitmain Information in this document is subject to change without notice and does not represent a commitment on the part of Bitmain Although the information in this document has been carefully reviewed Bitmain does not warrant it to be free of errors or omissions Bitmain reserves the right to make corrections updates revisions or changes to the information in this document Bitmaintech Pte Ltd T...

Page 3: ...ifications 7 2 Setting Up the Server 8 3 Configuring the Server 10 4 Monitoring Your Server 11 5 Administering Your Server 12 5 1 Checking Your Firmware Version 12 5 2 Upgrading Your System 12 5 3 Modifying Your Password 13 5 4 Restoring Initial Settings 13 Environmental Requirements 14 Regulations 16 ...

Page 4: ...d to an earthed mains socket outlet The socket outlet shall be installed near the equipment and shall be easily accessible 2 The equipment has two power inputs only by connecting those two power supply sockets simultaneously can the equipment run When the equipment is powered off be sure to power off all power inputs 3 Please refer to the layout above to place your goods in usage in case of any da...

Page 5: ... 5 T17 Server Installation Guide 1 Overview 1 1 T17 Server Components The main components and controller front panel of T17 servers are shown in the following figure ...

Page 6: ... Server Installation Guide 1 Overview APW9 Power Supply Note 1 Power supply APW9 is part of T17 server For detailed parameters please refer to the specifications below 2 Additional two power cords are needed ...

Page 7: ...rithm Coins T17 266 Aa SHA256 BTC BCH Hashrate TH s 64 00 Reference power on wall Watt 3200 Reference power efficiency on wall 25 C J TH 50 00 10 Hardware Configuration Miner Size Length Width Height w o package mm 1 1 298 0 175 0 304 0 Net weight kg 1 2 10 00 Notes 1 1 Including PSU size 1 2 Including PSU weight ...

Page 8: ...the following file IPReporter zip 3 Extract the file 4 Right click IPReporter exe and run it as Administrator 5 Select one of the following options Shelf Step Position suitable for farm servers to mark the location of the servers Default suitable for home servers 6 Click Start The file IPReporter zip is supported by Microsoft Windows only The default DHCP network protocol distributes IP addresses ...

Page 9: ...d it down until it beeps about 5 seconds The IP address will be displayed in a window on your computer screen 8 In your web browser enter the IP address provided 9 Proceed to login using root for both the username and password 10 In the Network section you can assign a DHCP IP address optional 11 Click Save Apply ...

Page 10: ...Description Pool URL Enter the URL of your desired pool The T17 servers can be set up with three mining pools with decreasing priority from the first pool pool 1 to the third pool pool 3 The pools with low priority will only be used if all higher priority pools are offline Worker Your worker ID on the selected pool Password The password for your selected worker 3 Click Save Apply to save and resta...

Page 11: ...Fatal Error Temperature is too high shown in the bottom of kernel log page 2 Monitor your server according to the descriptions in the following table Option Description ASIC Number of chips detected in the chain Frequency ASIC frequency setting GH S RT Hash rate of each hash board GH s Temp PCB Temperature of each hash board C Applied only to server with fixed frequency Temp Chip Temperature of th...

Page 12: ...ystem Version displays the date of the firmware your server uses In the examples below the servers are respectively using firmware version 20191019 5 2 Upgrading Your System Make sure that the T17 server remains powered during the upgrade process If power fails before the upgrade is completed you will need to return it to Bitmain for repair To upgrade the server s firmware 1 In System click Upgrad...

Page 13: ... the following options Reboot to restart the server with the new firmware Go Back to continue mining with the current firmware The server will load the new firmware next time when it is restarted 5 3 Modifying Your Password To change your login password 1 In System click the Administration tab 2 Set your new password then click Save Apply 5 4 Restoring Initial Settings To restore your initial sett...

Page 14: ...le the site should be chosen in the perennial upwind direction of the pollution source Please do not set your location within 3 7km from the seaside or the salt lake If unavoidable it should be built as airtight as possible equipped with air conditioning for cooling 1 3 Electromagnetic Environmental Conditions Please keep your site away from transformers high voltage cables transmission lines and ...

Page 15: ...rements of Corrosive Gas Corrosive Gas Unit Concentration H2S ppb 3 SO2 ppb 10 Cl2 ppb 1 NO2 ppb 50 HF ppb 1 NH3 ppb 500 O3 ppb 2 Note ppb part per billion refers to the unit of concentration 1ppb stands for the volume ratio of part per billion ...

Page 16: ...rence in which case the user will be required to correct the interference at his own expense EU WEEE Disposal of Waste Equipment by Users in Private Household in the European Union This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste Instead it is your responsibility to dispose of your waste equipment by handling it over...

Reviews: