- 11 -
T17+ Server Installation Guide
4. Monitoring Your Server
4.
Monitoring Your server
To check the operating status of your server:
1.
Click the status marked below.
Note: The T17+ server is with automatic frequency. Firmware will stop running when the Temp
(PCB) reaches to 75
℃
or
Temp(chips) reaches to 100
℃,
there will be an error message “Fatal Error:
Temperature is too high!” shown in the bottom of kernel log page.
2.
Monitor your server according to the descriptions in the following table:
Option
Description
ASIC#
Number of chips detected in the chain.
Frequency
ASIC frequency setting.
GH/S(RT)
Hash rate of each hash board (GH/s).
Temp(PCB)
Temperature of each hash board (°C). (Applied only to server with fixed frequency).
Temp(Chip)
Temperature of the chips on each hash board (°C).
ASIC status
One of the following statuses will appear:
●
O
- indicates OK
●
X
- indicates error
●
-
- indicates dead