background image

BT-36 Operation manual                                                              6 

P/N:36-ENG-OPM-EXP-R00 

Bistos 

2022.03 

 

Please do not modify or repair the device arbitrarily. The company has no 
responsibility for any malfunction or damage caused by disassembly. 

 

If you don’t use the device for a long time, remove the battery from the 
device and store it separately.   

 

Recycle the battery when replacing it. 

 

Do not use the device directly against fire or heating devices. 

 

Be sure to follow the safety regulations when using it for infants or newborns. 

 

If there is an abnormality in the body temperature measurement value, be 
sure to consult a doctor. 

 

Be careful not to damage the temperature sensing part or to get foreign 
substances in the sensor. 

 

If liquid permeates to the thermometer, it can cause malfunction and damage.   

 

When measuring temperature, check the temperature measurement mode.   

 

During measurement, if you look at the LCD screen while pressing the button 
to check the measurement value, it may show incorrect measured values. 
Always place the temperature sensing part on the measurement area or on 
the object target, and check the measurement result through LCD screen 
when you hear a notification sound after pressing the button.   

 

NOTE 
Body temperature measurement values cannot replace the specialist care or 
counseling.   
If the temperature reading is abnormal, please consult a doctor.   

 

 

 

2.

 

Product Configuration 

When unpacking the box, check all the following components are enclosed. The standard 
configuration is composed: 

Name 

User manual 

Main body 

Battery (AAA) 

Shape 

 

 

 

Qty. 

 

 

CAUTION 

 

Check consumables for wear or damage before use and replace if necessary.   

Summary of Contents for BT-36

Page 1: ...INFRARED THERMOMETER BT 36 Operation Manual In order to properly use this product please be sure to read the user s manual before use P N 36 ENG OPM EXP R00 This product is a medical device...

Page 2: ...The contents described in manual does not provide any additional warranties Bistos Co Ltd is not responsible for technical errors editing errors or omissions in the contents contained in manual The in...

Page 3: ...aration before use 9 3 2 Power on 10 3 3 Mode selection 10 3 3 1 Body Object temperature measurement mode 10 3 3 2 Sound On Off 10 3 3 3 Setting 10 3 4 Body temperature measurement 10 3 5 Object tempe...

Page 4: ...by rewarding from measured skin temperature in body temperature measurement mode The recommended part of BT 36 body temperature measurement mode is from 2 5 cm by the center of forehead BT 36 operate...

Page 5: ...gainst the ingress of solid object and liquid IP2X is protection against solid foreign object like a finger IPX2 is protection against some falling water drops vertically when enclosure tilted up to 1...

Page 6: ...and Storage for cleaning and disinfection Be cautious not to get dust or especially metallic objects into the device Do not place the device where it is too humid or changes temperature drastically Do...

Page 7: ...ates to the thermometer it can cause malfunction and damage When measuring temperature check the temperature measurement mode During measurement if you look at the LCD screen while pressing the button...

Page 8: ...is icon will show up on the screen and goes to Sound Off status If you press again it goes to Sound On status Default Sound On MODE selection button This button is to change the measurement mode If th...

Page 9: ...emperature or object temperature without any contacts is placed in this part Battery cover This device uses 2 AAA type batteries Press the top of the cover on the back of the device to open it insert...

Page 10: ...rature range 1 Human body 34 43 93 2 109 4 2 Object 15 50 59 122 Low battery icon If the battery voltage is low a Low battery icon is displayed on the upper right of the LCD screen to indicate that th...

Page 11: ...erature measurement Turn on the device with pressing START button Check the measurement mode whether is body temperature measurement mode Place the device 2 5 cm distance from center of forehead Start...

Page 12: ...measured value displayed If the measured value exceeds the measurable temperature range then the red light is illuminated with the error Err When measuring any movement may affect the temperature read...

Page 13: ...y place for at least 12 hours If the measurement is not working properly When measuring infants or children if they struggle too much measurement errors may occur because the distance between the skin...

Page 14: ...ment mode Measuring method Infrared sensing of skin surface Non contact measurement Display method Mono LCD Expected lifetime 1 year Power Battery 3V 1 5V AAA battery 2EA Standard configuration User M...

Page 15: ...ssions or decreased electromagnetic immunity of this device and result improper operation Electric medical devices require special precautions regarding EMC and should be used in accordance with the E...

Page 16: ...4 2 8 kV Contact 2 kV 4 kV 8 kV 15 kV Air 8 kV HCP 8 kV VCP Complies Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at le...

Page 17: ...ered by batteries only Surge IEC 61000 4 5 1 kV line s to line s 2 kV line s to earth Not applicable Power frequency 50 Hz and 60 Hz magnetic field IEC 61000 4 8 30 A m Complies Power frequency magnet...

Page 18: ...ess Contact Seller Bistos Co Ltd Manufacturer Bistos Co Ltd Thank you for purchasing the Contactless infrared thermometer This product has passed through strict quality control and inspection The comp...