background image

w w w . b i s s e l l . c o m   8 0 0 . 2 3 7 . 7 6 9 1

I

MPORTANT SAFETY INSTRUCTIONS

 3

When using an electrical appliance, basic 

precautions should be observed, including 

the following: 

Read all  

instRuctions 

befoRe using youR  

upRight VacuuM. 

 

Always connect to a polarized outlet  

(left slot is wider than right). Unplug from 

outlet when not in use and before conducting 

maintenance. 

  

WaRning:

 to 

reduce the risk of fire, 

electric shock, or injury:

 

 

Do not modify the polarized plug to fit a  

non-polarized outlet or extension cord.

 

Do not leave vacuum cleaner unattended 

when it is plugged in.

 

Unplug from outlet when not in use and  

before servicing.

 

Do not use outdoors or on wet surfaces.

 

Do not allow children to operate vacuum  

cleaner or use as a toy.

 

Close attention is necessary when used 

by or near children.

 

Do not use for any purpose other than 

described in this user’s guide.

 

Use only manufacturer’s recommended  

attachments.

 

Do not use with damaged cord or plug.

 

If appliance is not working as it should, 

has been dropped, damaged, left out-

doors, or dropped into water, have it 

repaired at an authorized service center.

 

Do not pull or carry by cord, use cord as 

a handle, close a door on cord, or pull 

cord around sharp edges or corners. Do 

not run appliance over cord. Keep cord 

away from heated surfaces.

 

Do not unplug by pulling on cord. To 

unplug, grasp the plug, not the cord.

 

Do not handle vacuum cleaner or plug 

with wet hands.

 

Do not put any object into openings. Do 

not use with any opening blocked; keep 

openings free of dust, lint, hair, and  

anything that may reduce air flow.

 

Keep hair, loose clothing, fingers, and all 

parts of body away from openings and 

moving parts.

 

Turn off all controls before plugging or 

unplugging vacuum cleaner.

 

Use extra care when cleaning stairs.

 

Unplug before attaching the TurboBrush

®  

Tool

 

Do not pick up flammable materials 

(lighter fluid, gasoline, kerosene, etc.) or 

use in the presence of explosive liquids 

or vapors.

 

Do not pick up toxic material (chlorine 

bleach, ammonia, drain cleaner, etc.).

 

Do not use vacuum cleaner in an 

enclosed space filled with vapors given 

off by oil base paint, paint thinner, some 

moth proofing substances, flammable 

dust, or other explosive or toxic vapors.

 

Do not pick up hard or sharp objects 

such as glass, nails, screws, coins, etc.

 

Do not pick up anything that is burning or 

smoking, such as cigarettes, matches, or 

hot ashes.

 

Do not use without filters in place.

 

Use only on dry, indoor surfaces.

 

Keep appliance on a level surface.

 

Do not carry the vacuum cleaner while it 

is running.

 

Brush may unexpectedly restart. Unplug 

from outlet when cleaning or servicing

saVe these  

instRuctions 

foR futuRe use

this appliance 

has a polaRiZed 

plug.

To reduce the risk of electric shock, this 

appliance has a polarized plug (one blade 

is wider than the other). This plug will fit in 

a polarized outlet only one way. If the plug 

does not fit fully in the outlet, reverse the 

plug. If it still does not fit, contact a qualified 

electrician to install a proper outlet. Do not 

change the plug in any way.

This model is for household use only.

Summary of Contents for OptiClean 30C7 SERIES

Page 1: ...DE 30C7 SERIES Safety Instructions Product View Assembly Operations Maintenance and Care Troubleshooting Consumer Services Replacement Parts 3 4 5 6 6 9 10 15 16 17 20 18 Accessories Warranty Product...

Page 2: ...um is well made and we back it with a limited three year warranty We also stand behind it with a knowl edgeable dedicated Consumer Services department so should you ever have a problem you ll receive...

Page 3: ...y object into openings Do not use with any opening blocked keep openings free of dust lint hair and anything that may reduce air flow Keep hair loose clothing fingers and all parts of body away from o...

Page 4: ...ry Handle Upper Tank Easy Empty Dirt Container Pre Motor Filter Lock n Seal Lever Brush Post Motor Filter Foot Window Inner Cyclone Screen Wide Cleaning Foot Power Switch Pet Contour Tool 30C7T model...

Page 5: ...cord wrap and remaining two screws 2 Attach the extension wand support to the rear of the unit Extension wand support should be placed about half way down the vacuum body Using one of the two remainin...

Page 6: ...rward 2 The cleaner can also be moved by using the carry handle on the front Power Cord To store power cord wrap cord around the upper cord wrap and lower extension wand support Once wound tightly use...

Page 7: ...ove up one setting Medium settings for medium pile carpet High setting for high pile and most shag frieze carpet Note For optimal carpet cleaning performance adjust to the lowest practical setting If...

Page 8: ...th desired attachment for longer reach 2d TurboBrush Tool Use rotation brush action for small flat areas such as stairs and furniture Press gently down and pull towards you in raking motion too much p...

Page 9: ...one screen and twist counterclockwise until the locking tabs stop the rotation Pull down the inner cyclone screen to remove it 3 Clean the inner cyclone with a cloth or soft brush to remove dust or de...

Page 10: ...n process to return clean air to the room It is located under the pre motor filter tray Unit must be reclined to locate the post motor filter The post motor filter cartridge should be replaced if mach...

Page 11: ...see cleaning the dirt container on page 9 6 Grasp the hose wand and separate it from the hose wand base Check for a clog in the base the wand or in the hose 7 Remove the Twist n Snap hose from the va...

Page 12: ...dirt cup dirty filters or clog 3 Follow the steps for checking filters and clearing clogs on pages 10 and 11 4 When the motor cools for approximately 30 minutes the thermal protector automatically re...

Page 13: ...utlet 2 Place handle in low position and turn vacuum cleaner over so bottom side is fac ing up 3 Remove the six screws on the sole plate with a Phillips head screwdriver Lift the brush cover off 4 Gra...

Page 14: ...ne BISSELL replacement parts Generic belts may not meet the exact specifications required to keep your vacuum operating at its peak performance The use of unbranded belts could lead to early failure o...

Page 15: ...tool from hose or from vacuum 2 Twist collar so opening is at the top and lift top cover to remove 3 Remove the brush from the belt and clean debris 4 Replace the brush inside the belt and place ends...

Page 16: ...Broken or worn drive belt 5 Replace drive belt see page 14 6 Rotating floor brush bristles worn 6 Replace brush see page 13 7 Rotating floor brush jammed 7 Remove brush and clean debris from brush en...

Page 17: ...rs missing or installed incorrectly 2 Check pre motor and post motor filters for correct installation see page 10 3 Dirt container installed incorrectly 3 Pull out and re insert dirt container correct...

Page 18: ...510 Post Motor Filter These items are available for purchase as accessories for your BISSELL OptiClean To purchase call 1 800 237 7691 or visit www bissell com Item Part No Part Name 1 203 1056 Crevic...

Page 19: ...SSELL product should require service Contact BISSELL Consumer Services to locate a BISSELL Authorized Service Center in your area If you need information about repairs or replacement parts or if you h...

Page 20: ...p m ET Or write BISSELL Homecare Inc PO Box 3606 Grand Rapids MI 49501 ATTN Consumer Services Or visit the BISSELL website www bissell com When contacting BISSELL have model number of cleaner availabl...

Reviews: