background image

w w w . b i s s e l l . c o m  

7

O

perations

Your BISSELL Cleanview Pet Ultimate 

is not only a powerful carpet and rug 

vacuum cleaner, it’s also a versatile 

above floor vacuum cleaner when 

you select one of the special tools.

Pet Tool Adapter:

The Pet Tool Adapter must be 

attached to the handle end of the 

flex hose to use the Pet Contour Tool 

and the Wide Pet TurboBrush. The 

narrow end of the adapter attaches 

to the handle end of the flex hose 

and the wide end of the adapter 

attaches to the pet tool of your 

choice. The adapter should fit snugly 

to the hose and pet tool without 

using excessive force.

Pet Contour Tool:

Use to reach into corners and edges 

on stairs, as well as armrests and 

other curved surfaces. The tool can 

be flipped to use in any direction.

TurboBrush Pet tool:

Use rotating brush action for small 

areas such as stairs, upholstery and 

pet beds.

NOTE: Press gently when using the 

TurboBrush Pet tool to gain maximum 

cleaning. Too much pressure will cause 

the brush to stop rotating.

Two types of cleaning tools in one 

attachment.
1.

  Rotate brush portion up to use as a crevice 

tool to vacuum in tight, narrow spaces.

2.

  Rotate brush portion down to use as a 

dusting brush to dust furniture, blinds, 

books, lamps, shelves and baseboards

Tip

Before cleaning under 

low furniture, check 

area first for objects 

that might harm the unit 

or block the hose

.

Combination Crevice Tool/Dusting Brush:

Summary of Contents for CLEANVIEW 59M5

Page 1: ...ank You USER S GUIDE 59M5 SERIES 220 240V Safety Instructions Product View Assembly Operations Maintenance and Care Troubleshooting Replacement Parts 3 4 5 6 9 10 12 13 14 Warranty Consumer Services 1...

Page 2: ...ll made and we back it with a limited one year warranty We also stand behind it with a knowledgeable dedicated Consumer Services department so should you ever have a problem you ll receive fast consid...

Page 3: ...physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their sa...

Page 4: ...Particulate Air HEPA filter specification EN 1822 1 2009 Handle Telescoping Extension Wand Air Flow Regulator Automatic Cord Rewind Button Brush Switch Pet Hair Lifter Power Button Bag Change Indicato...

Page 5: ...ip located on the back of the floor nozzle into the storage slot on the rear of the vacuum 2 To store without the floor nozzle attached insert the storage clip located on the bottom of the telescoping...

Page 6: ...automatic cord rewind When cleaning is finished press the power button OFF and grasp the plug to disconnect from the electri cal outlet Hold the plug and press the automatic cord rewind button to rew...

Page 7: ...rce Pet Contour Tool Use to reach into corners and edges on stairs as well as armrests and other curved surfaces The tool can be flipped to use in any direction TurboBrush Pet tool Use rotating brush...

Page 8: ...f the Pet Hair Eraser Floor Nozzle Then push the brush switch to the carpet position to pull the brushes up into the Pet Hair Eraser Floor Nozzle 2 To vacuum bare floors push the brush switch to the b...

Page 9: ...giving off less dust emissions It also holds more fine dust particles giving you longer lasting suction power Bag change indicator The bag change indicator is located between the power button and the...

Page 10: ...rom the holder by pressing the dust bag holder clip and pulling the dust bag out of the holder Discard the used dust bag 5 Slide the new dust bag into the holder by inserting the dust bag into the tab...

Page 11: ...replacing 5 Place the filter back into the filter frame and replace back into the f ilter holder NOTE The filter frame should be placed so the protective frame is visible 6 Place dust bag holder and d...

Page 12: ...o tabs at the top of the filter door and pushing down on the bottom of the filter door 1 Unplug the vacuum from electrical outlet 2 If a clog is present or debris is visible turn the collar on the nec...

Page 13: ...5 Check hose and replace if needed 6 Air flow regulator or variable suction power 6 Change to closed or maximum setting control is set to open or minimum setting 7 TurboBrush Pet tool is clogged or d...

Page 14: ...0 Dust Bag 3pk 2 203 7268 Pre Motor Filter 3 203 7269 Post Motor HEPA Media Filter 4 203 7275 Pet Hair Eraser Floor Nozzle 5 203 7277 Pet Hair Lifter 6 203 7257 Flexible Hose with Handle 7 203 7256 Te...

Page 15: ...ance components such as filters belts or brushes Damage or malfunction caused by negligence abuse or use not in accordance with the User s Guide is not covered BISSELL HOMECARE INC IS NOT LIABLE FOR I...

Page 16: ...nt parts please contact the numbers below Or visit the BISSELL website www bissell com When contacting BISSELL have model number of cleaner available Please record your Model Number __________________...

Reviews: