background image

13

SYSTEM SETUP Menu

The SYSTEM SETUP menu is used to set the items related to 

the camera system.

OSD

  EXPOSURE
  WHITE BALANCE
  PICTURE
  LENS PARAMETERS
  SYSTEM SETUP
  FUNCTION SETTING
  SAVE AND EXIT
  EXIT

SYSTEM SETUP MENU

  FACTORY DEFAULT
  DISPLAY CONFIG.
  INTERFACE SET
  FLIP
  SDI VIDEO
  PAN DIRECTION
  TILT DIRECTION
  PROPORTIONAL PT
  SET NORTH
  SYSTEM INFO
  SYSTEM RESET

OFF
1080P30
NORMAL
NORMAL
ON

FACTORY DEFAULT:

 The menu is used to restore the factory 

settings.

DISPLAY CONFIGURATION:

 Entered the menu of DISPLAY 

CONFIGURATION, it will be shown the below items:

ZOOM LENS POSITION:

 Select ON to display the zoom 

lens position on the screen.

DIRECTION INDICATOR:

 Select ON to display the direc-

tion indicator on the screen.

INTERFACE SET:

 This menu is used to set the following:

CAMERA ID:

 Factory Default Setting: 001. Use RS485 Pel-

co-D can control up to 255 cameras, camera ID from 001 

to 255 has to be set. Use RS422 VISCA protocol can con-

trol up to 7 cameras, camera ID from 1 to 7 has to be set.

BAUD RATE:

 Factory Default Setting: 9600. Select 

the baud rate from the following: 2400, 4800, 9600, 

38400bps.

FACTORY FORMAT:

 Set factory default format.

NOTE!

•  After the camera ID and Baud rate is set, to activate 

the new set camera ID and Baud rate, the camera has 

to be rebooted by powering the camera OFF and ON.

•  For Dual-Output camera, the camera ID and Baud rate 

on IP web interface has to be set to the same ID as the 

camera’s for IP control.

•  You may need to reboot the keyboard after you change 

the camera ID and Baud rate.

•  Once modified and saved the camera ID and baud rate, 

please modify the corresponding parameters on both 

the keyboard and IP web interface setting, otherwise 

the camera and keyboard and IP control will be unable 

to communicate.

FLIP:

 Select ON to flip the image if you need to lift the camera.

VIDEO FORMAT:

 SDI + IP True Dual Output: You can have 

parallel SDI and IP video output. Either SDI or IP video format 

can be set up independently for having dual output simulta-

neously.

•  SDI output: Select the SDI video output format from the 

following: 1080p 60, 59.94, 50, 29.97, 25; 1080i 60, 59.94, 

50; 720p 60, 59.94, 50, 29.97, 25

•  IP output: Select the IP video output format from the fol-

lowing: 1080P:30/25, 720P:30/25

Follow the steps to change the video format:

1.  Set SDI video resolution in SYSTEM SETUP.

2.  Select the SDI VIDEO format you want to have.

3.  Waiting for a while for camera new set video format be-

ing taken. It is normal that you cannot take the control of 

the interface while the video format is being changed. 

You can reboot the camera by powering OFF and ON 

to active the new set video format if it takes too long to 

complete the format changing by itself.

4.  Go to IP camera Web Interface), you can set IP video res-

olution.

PAN DIRECTION: NORMAL/INVERT

. Supports normal and 

inverted directions on Pan movement.

TILT DIRECTION: NORMAL/INVERT

. Supports normal and 

inverted directions on Tilt movement.

PROPORTIONAL PT:

 Turn ON to automatically adjust the 

Pan and Tilt speed with various zoom ratios. For example, 

the higher zoom ratio you use, the slower the speed of P/T. 

Turn OFF to inactivate the feature to set the flat speed of Pan 

and Tilt.

SET NORTH: 

Select ON to open this function. Turn the cam-

era to the north, and then save it by call preset 1.

SYSTEM INFO:

 CAMERA ID, BAUD RATE, SDI VIDEO, IP VID-

EO: Modify in the menu of “INTERFACE SET”.

VERSION:

 The version of the software.

SYSTEM RESET:

 To save the changes have been made and 

make the changes activated.

EXIT:

 Push the joystick to the right to exit this level menu.

Summary of Contents for BDA200

Page 1: ...EYES A200 FULL NDI NO COMPROMISES USER GUIDE PART 1...

Page 2: ...Injector 8 Mounting the Camera 8 Use SDI video output 9 Starting the Camera 9 Setup Camera ID Baud Rate and Control Protocol 9 Controlling the Camera 10 Adjusting and Setting with Menus 11 EXPOSURE Me...

Page 3: ...nd other BirdDog s trademarks and logos are the property of BirdDog Australia Other trademarks company names and product names contained in this manual are the property of their respective owners Trad...

Page 4: ...a clean cloth with a bit of ethanol and wipe it gently If the camera will not be used for an extended period of time put on the lens cap to protect the sensor from dirt Do not aim the camera lens at t...

Page 5: ...p to 100Meters IR ON OFF is available Outdoor Environmental Rating IP67 Corrosion Resistant Treatment Various Image Functionalities WDR BLC Defog Day Night Supports 120 tilt 360 pan range adaptive spe...

Page 6: ...larm Output x1 Cat5 6 Network Cable 80W PoE Coaxial Cable Data CableA nalog Audio Signal Data CableA larm Inputs x2 Data CableA larm Output x1 SDI Signal CAMERA SIDE CONTROL SIDE NOTE All cables are t...

Page 7: ...to each other and the clamp of the cable connector is intact SDI Signal Cable In order to ensure the quality of the installation of the project the HD SDI and 3G SDI signals have a high data transmiss...

Page 8: ...the camera NOTE When mounting the camera please install the bracket adapter to the bracket first and then mount the camera to the bracket Tighten all the screws to hold the camera securely For waterp...

Page 9: ...tion TX TX RX RS 485 A RS 485 RS 485 D RX RS 485 B RS 485 RS 485 D 1 2 RS422 VISCA control connection diagram SONY Keyboard RS422 Connection VISCA None Sony Keyboard RS422 Connection Setup Camera ID B...

Page 10: ...match the control system or keyboard camera ID and Baud Rate setting to the cameras PTZ Control 1 8 9600 None None 1 PELCO D Port Mode Stop Bits Data Bits Baud Rate Flow Control Parity Address Code PT...

Page 11: ...ake the subject appear clearer This is set to ON OFF WIDE D Wide dynamic range mode ON OFF The cam era distinguishes light and dark areas within the same scene adjusts the brightness for dark areas an...

Page 12: ...form manual A F RECOVER TIME When the camera is not in operation if in the manual focus mode after the A F RECOVER TIME it will automatically transfer to the automatic focus If the time is 0 then the...

Page 13: ...erwise the camera and keyboard and IP control will be unable to communicate FLIP Select ON to flip the image if you need to lift the camera VIDEO FORMAT SDI IP True Dual Output You can have parallel S...

Page 14: ...resets still store camera positions and image parameters but 17 128 presets will only store camera positions You can set the presets to number 17 128 if you don t want the preset to memorize the image...

Page 15: ...e camera scan 1 Push the joystick to the right to enter this setting menu PRESET NUMBER 000 000 000 000 DEFAULT DWELL 000 000 000 000 PRESET NUMBER 000 000 000 000 DEFAULT DWELL 000 000 000 000 PRESET...

Page 16: ...16 Dimensions Unit mm 30 333 176 6 47 2 211 R75...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...WELCOME TO THE FUTURE bird dog tv hello bi rd dog tv...

Reviews: