Pro
Loop
Programmable loop detector for controlling of
gates and barriers as well as for regulating and
counting cars in parking areas
1
Installation of the loop detector
The loop detectors must only be placed in dry rooms or control cabinets that are protected against all types of moisture and wetness. The ambient temperature is not
allowed to exceed 60 °C. The connection wire to the loop must be twisted at least 20 times per metre or be shielded. The installation of the induction loop is described in
other operating instructions.
Operating indicator:
Green = Automatic
Orange = Simulation
Red = Fault
Multifunctional LCD display
Programming buttons
Mode/Sim1 button – Data/Sim2 button
Operating mode
A = Automatic mode
and parameter indicator
C = Loop calibration during start-up phase
S = Software version during start-up phase
H = Hardware version during start-up phase
t = Information about the type used during the start-up phase
S = Simulation
u = Inductance display
E = Error
0–9 = Parameter no.
Loop symbols
Loop 1
Loop 2
Operating mode indicator
A: Time function t, basic function 1–4
S: Simulation of outputs, loop inductance in µH
E: 3-digit error code
6
2
1
5
4
3
2
1
2
Overview
3
Electrical connections
Operating Instructions
(Translation)
Quality
international
level
EN ISO
9001
1
2
6
5
3
4
L3
L4
31
32
34
24
+/~
–/~
A1
A2
21
22
14
11
12
31
32
34
24
+/~
–/~
A1
A2
21
22
14
11
12
L3
1
2
L4
L5
L6
Loop
Alarm (optional)
Power
Out 2 (optional)
Out 1
Alarm (optional)
Power
Out 2
Out 1
Loops 1 + 2
1-loop device
2-loop device
All terminal blocks are plugga-
ble. They can be
removed for connecting
and maintenance.