8
9
Conformities
7
Troubleshooting
8
Technical data
10
Warranty and liability
11
Contact
Bircher Reglomat AG
Wiesengasse 20
CH-8222 Beringen
www.bircher-reglomat.com
Manufacturer:
Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen
Following directives have been observed:
RoHS 2011/65/EU, RED 2014/53/EU
Product variant
Herkules 2E
This device meets the requirements of Part 15 of the FCC regula-
tions and the RSS-210 standard of Industry Canada.
Warning:
Changes or modifications made to this equipment not
expressly approved by Bircher Reglomat AG may void the FCC
authorisation to operate this equipment.
1. The warranty and liability of Bircher Reglomat AG are based on the sales con-
tract.
2. The warranty and liability shall expire prematurely, should the client or third
parties not use and/or operate the product in compliance with existing opera-
ting instructions, should incorrect changes or repairs be made by the client or
third parties, should the client or third parties, when a fault has occurred, not
take suitable steps at once for a reduction of possible damage/losses and offer
Bircher Reglomat AG a chance for remedying the said fault.
3. The warranty and liability shall exclude any damage for which there is no proof
that it is due to poor materials, faulty construction, poor workmanship, and any
damage caused by other reasons, for which Bircher Reglomat AG cannot be held
liable.
4. No liability can be assumed for any consequential damage, provided this is not
governed otherwise by applicable product liability laws and regulations.
5. Warranty claims made against the seller on the basis of the sales agreement
are not affected by these regulations.
6. For the benefit of its customers Bircher Reglomat AG constantly develops its
products further. Bircher Reglomat AG reserves the right to make changes to any
of the products described in this document without prior notice.
Fault
Remedy
People/vehicle separation does not work as expected
Check mounting height & setting (recommended > 3 m)
Check mounting situation & environment (best: sensor centered above door)
Check setting/clip for wide field pattern
Late detection of traffic
Increase field size/sensitivity
Adjust inclination angle to move the pattern away from the door
Door reverses (sensor reacts to closing door)
Adjust inclination angle to move the pattern away from the door
Reduce field size/sensitivity
Make sure sensor is tightly fixed and its mounting support does not vibrate
Door opens without motion of a vehicle (or person)
Mount sensor away from EMC interference (e.g. fluorescent tubes, HID lamps,
wireless system, motor/inverter, etc.)
Point pattern away from EMC interference
Activate interference filter
Door does not activate though sensors signals detection (LEDs) Check wire colors against output selection
Late detection or non-detection of people
Reduce mounting height (recommended < 5 m)
Door stays open
Change output logic
Technology
Doppler radar with planar module
Transmitting frequency
24.05–24.25 GHz
Transmitting power
< 20 dBm
Operating voltage
12–28 VAC, 12–36 VDC (45-65 Hz)
Operating current
max 75 mA
Temperature range
–30° bis 60° C
Air humidity
0% to 95% relative,
without condensation
Mounting height
2 to 7 m
Relay outputs
Switching voltage
Switching current
Potential-free changeover contacts
max 48 VAC/DC
max 0.5 A AC
Housing
Aluminium black anodized,
Cover Polycarbonat
Dimensions
134 x 82 x 75 mm
Weight
820 g incl. cable
Protection class (EN 60529)
IP 65
Max. detection speed
25 km/h for vehicles
Cable
Length 10 m, 6 x 0.20 mm
2
Suitable for the following
countries
EU, EFTA, US, CA
9.2
FCC approval
9.1
EC-Declaration of Conformity
Seller
Swissdoor ApS
Stenhuggervej 2
DK-5471 Søndersø
Tel.: +45 86 28 00 00
[email protected]