Explanation of functions and settings

5.1

General description of the remote control

5.2

Function of the «Reglobeam» remote control

5.6

Configuration with keys

5.3

Layout of the «Reglobeam» remote control 

5.4

Configuration mode

5.5

Establishing the connection

The Reglobeam remote control allows you to program Herkules 2 easily
and conveniently from the ground. Data transfer between Reglobeam and
Herkules 2 functions in both directions, i.e. to and from the detector, and
is  guaranteed  by  an  infrared  interface.  The  Reglobeam  reads  back  the
adjusted  values  immediately  after  programming  and  displays  them  for
control purposes. This ensures safe and correct programming.

Please refer to the first part (4.6) for an overview of individual parameters
and the enhanced level settings.

Note:

Programming must be carried out within 30 s. If this time elapses,

it is necessary to activate programming mode again (press key G

The «Reglobeam» remote control functions using a combination of func-
tions and number keys. Take care to operate it correctly as described in
chapter 4.2.
Flashing keys on the Reglobeam indicate that the data has not been fully
transmitted.  Avoid  exposing  the  infrared  interface  to  direct  sunlight  or
other light sources.

The  connection  between  the  Reglobeam  and  Herkules  2  can  only  be
established  when  the  detector  is  in  configuration  mode.  Configuration
mode is activated when the detector is switched on. For safety reasons,
this mode is automatically deactivated 30 minutes after the last setting
has been made on the detector. Configuration mode can be exited at any
time by pressing keys A+4.

Configuration mode can be activated in three different ways:

a)  

By pressing any key X or Y key on the detector

Changing the function

Press key X. The value increases by 1 for every key press (function no.).
Once the last function has been reached, the program jumps back to the
first function. The green LED then indicates the number of the activated
function.

Changing the level

Press key Y. The value increases by 1 for every key press (level). Once the
last level has been reached, the program jumps back to the first level.

Exiting programming mode

Exit programming mode by pressing both keys X and Y briefly at the same
time.

X

Y

Key

Key

X

Y

Key

Key

b) 

By restarting the detector (disconnecting the supply voltage)

c) 

Access via remote control with access code

Press start key G on the Reglobeam

If the connection has been established successfully, G and one of the
keys 1 to 7 light up (address of the detector)

If G flashes, the connection could not be established

Hold the remote control closer to the detector and point directly at it

Check the batteries of the Reglobeam.

Replace the batteries if nothing lights up.

Configuration  mode  is  not  activated  if  G  and  one  of  the  keys  1  to  7

light up although no further settings are possible.

Primary mode:

Press keys X and Y simultaneously and hold for 2 s  

➔ 

Green LED lights up, then release

Secondary mode:

Press keys X and Y simultaneously and hold for 4 s 

➔ 

Red LED lights up, then release

Reset:

Press keys X and Y simultaneously and hold for 8 s 

➔ 

Both LED lights up, then release

Mode

Parameter (key X)

Function no. Level key Y

Primary

Enhanced level 

1

1–8

Mounting height 

2

1–7

Relay parameter setting 

3

1–8

Field size 

4

1–9

Sekundär

Relay hold interval 

1

1–5

Direction recognition 

2

1–3

Crossing traffic masking 

3

1–9

Wide field

4

1–2

SMD level 

5

1–9

SMD field size 

6

1–9

Digital filter function 

7

1–2

Numerical keys 

to 

1

9

Battery
compartment

Infrared interface

Function keys

to 

F

A

Locking
screw

Start 

G

Front side

Rear side

Procedure

Press keys X and Y at the
same time to access the
required mode.

Summary of Contents for Herkules 2

Page 1: ...nom r ckvidden f r en fj rrstyrning Givaren m ste monteras p en plan yta Undvik vibrationer F rem l som v xter flaggor fl ktar osv f r inte komma in i detektorf ltet Givaren f r inte t ckas ver med lo...

Page 2: ...av str mf rs rjningen Med beh righetskod med fj rrstyrningen Idrifttagningsfas SMD Slow Motion Detection Minimala n stan statiska r relser detekteras s snart porten ppnar Den st ngs f rst n r ingen r...

Page 3: ...arn Alternativ 5 R2 Mot radarn R1 fr n radarn Alternativ 8 R2 Mot radarn R1 fr n radarn Alternativ 5 R2 mot radarn R1 fr n radarn Alternativ 1 R2 fordon R1 person Alternativ 1 R2 fordon R1 person Alte...

Page 4: ...n p separata utg ngar Standard port Reagerar endast p Fordon Standard port Reagerar endast p personer Standard port Personer och Fordon p samma utg ng Standard port Personer och Fordon En riktning per...

Page 5: ...av funktion Genom tryckning p knappen X Varje tryckning h jer v rdet med v rdet 1 Funktions nr N r den sista funktionen r n dd hoppar programmet ter till f rsta funktionen Gr n LED anger d numret p d...

Page 6: ...v rtrafik V rde 9 Porten ppnar vid tv rtrafik eller n rmanden fr n sidan Steg 1 Fj rrstyr ning Funktion Knappar C 1 Standard k nner av alla objekt P 1 1 C 2 Trafik rakt framifr n mot radarn alla objek...

Page 7: ...var koden fel B rja om vid 1 Tryck samtidigt knapparna X och Y under 8 sekunder Varannan sekund blinkar b da LED kort Apparaten r terst lld till fabriksinst llningarna Funktion Beh ringhetskod r fr n...

Page 8: ...0 14 mm2 Godk nnande CE 0682 FCC IC L nder EU EFTA US CA F ltm tt vid 30 lutning Fr n 2 5 m x 3 m BxD H jd 2 m Till 5 m x 7 m BxD H jd 7 m EG F rs kran om verenst mmelse Bircher Reglomat AG uppger h...

Page 9: ...dde af en fjernbetjening F leren skal fastmonteres p en plan flade Undg vibrationer Objekter som fx planter flag ventilatorer osv m ikke komme inden for registreringsfeltet F leren m ikke v re d kket...

Page 10: ...f leren x eller y at afbryde str mtilf rslen hj lp af adgangskoden og fjernbetjeningen Opstartsfase SMD Slow Motion Detection De mindste n sten um rkelige bev gelser registreres s snart porten bnes Re...

Page 11: ...af rel er Trin 5 R2 forl ns R1 bagl ns Trin 5 R2 forl ns R1 bagl ns Trin 8 R2 forl ns R1 bagl ns Trin 5 R2 forl ns R1 bagl ns Trin 1 R2 K ret j R1 person Trin 1 R2 K ret j R1 person Trin 6 R2 K ret j...

Page 12: ...soner k ret jer Standard port undertrykkelse af personer Standard port undertrykkelse af k ret jer Standard port personer k ret jer samme udgang Standard port personer k ret jer udgange retningsadskil...

Page 13: ...f leren Funktions ndring Ved tryk p knap X Pr tryk p knappen forh jes v rdien med 1 funkti onsnr N r den sidste funktion er n et springer programmet igen til den f rste funktion Den gr nne LED angive...

Page 14: ...afik Trin 9 Port bner ved krydsende trafik eller sidev rts tiln rmelse trin 1 Fjernbet jening Funktion Knapper C 1 Standard registrerer alle objekter P 1 1 C 2 Frontal trafik alle objekter P 1 2 C 3 H...

Page 15: ...og Y og hold dem nede i 8 sekunder Hvert 2 sekund lyser begge LED kort Enheden er tilbagestillet til fabriksindstilling Funktionen adgangskode er sl et fra Kode slettet Ny initialiserings og indl ring...

Page 16: ...lande EU EFTA US CA Feltdimensioner ved 30 h ldning fra 2 5 m x 3 m BxD h jde 2 m til 5 m x 7 m BxD h jde 7 m EU Overensstemmelseserkl ring Hermed erkl rer Bircher Reglomat AG at produktet Herkules op...

Page 17: ...oles according to values given 2 Route cable through opening provided in mounting bracket and make sure length is sufficient for wiring 3 Screw mounting bracket on tightly 4 Hook detector into mountin...

Page 18: ...tector x or y Interrupting electrical power supply Via access code on remote control Start up phase SMD Slow Motion Detection The slightest quasi static movements are detected as soon as the industria...

Page 19: ...backwards Level 5 R2 forwards R1 backwards Level 8 R2 forwards R1 backwards Level 5 R2 forwards R1 backwards Level 1 R2 Vehicle R1 Person Level 1 R2 Vehicle R1 Person Level 6 R2 Vehicle R1 Level 1 R2...

Page 20: ...hicles Standard industrial door people suppression Standard industrial door vehicle suppression Standard industrial door people and vehicles same output Standard industrial door people and vehicles ou...

Page 21: ...hanging the function Press key X The value increases by 1 for every key press function no Once the last function has been reached the program jumps back to the first function The green LED then indica...

Page 22: ...laterally level 1 Remote control Function Keys C 1 Standard detects all objects P 1 1 C 2 Frontal traffic all objects P 1 2 C 3 High speed industrial door all objects P 1 3 C 4 Detects slow movements...

Page 23: ...imultaneously and hold for 8 seconds Both LEDs light up briefly every 2 s Device is reset to factory settings Access code function is switched off Code deleted New initialisation and teach in phase st...

Page 24: ...m x 3 m WxD height 2 m to 5 m x 7 m WxD height 7 m EU Declaration of Conformity Bircher Reglomat AG herewith declares the product Herkules 2 to be in conformance with the basic requirements and other...

Reviews: