36
Item code present on serial label
Type of part
Part code
Spare parts Q.ty
BXMCB2 - BXMCB2TFD125
Condensatore Tipo B
BXCONB
2
BXMCC2 - BXMCC2TFD160
Condensatore Tipo C
BXCONC
2
BXMCC4 - BXMCC4TFD200
Condensatore Tipo C
BXCONC
4
BXMCC6
Condensatore Tipo C
BXCONC
6
BXMCH4
Condensatore Tipo H
BXCONH
4
BXMCH6
Condensatore Tipo H
BXCONH
6
For further information, consult the website www.bioxigen.com or send an email to [email protected].
1.
Turn off the device using the
lighted green 0/I switch
, moving it to the 0 position.
2.
Unplug it.
3.
Unscrew the cover, holding the box cover up by the handle.
4.
Gently unscrew the quartz condenser using the red plastic bushing at the base of the condenser. Remove the
device by pulling it out of the box fixed to the wall, by supporting it from the handle with linear movement until you
extract completely the glass condensers.
5.
Remove the mesh (R) from the outside of the tube. If the operation is difficult, lightly rotate the mesh around the
quartz condenser.
6.
Clean the condenser with a slightly damp cloth.
WARNING!!
Do not use detergents, soaps or the like
7.
Clean the mesh under hot running water and dry thoroughly with a cloth.
8.
Make sure the condenser has no cracks or other damage. If it does, replace it.
9.
As soon as you notice a white coating on the metal grill inside the condenser, it must be replaced.
Generally, the tube must be replaced within a maximum of 18 months. Condenser replacement is
suggested every 8.000 to 14.000 hours of continuous operation and must be done within 18 months. This
variability depends upon the quality of the air that is treated.
10. Reset the metal mesh on the condenser overlapping the inner grill.
6.3 Cleaning device procedure