5.Technical Parameter

5.1 Optical parameter

Zoom

magnification

Working

distance

(mm)

Eyepiece

Eyepiece (optional)

WF10X/22mm

WF15X/16mm

WF20X/12mm

magnification

Field of

view(mm) magnification

Field of

View(mm)

magnification

Field of

view(mm)

0.67X

105

6.7X

32.8

10.05X

23.9

13.4X

17.9

0.7X

7X

31.4

10.5X

22.86

14X

17.1

0.8X

8X

27.5

12X

20

16X

15

1X

10X

22

15X

16

20X

12

1.5X

15X

14.7

22.5X

10.7

30X

8

2X

20X

11

30X

8

40X

6

3X

30X

7.3

45X

5.3

60X

4

4X

40X

5.5

60X

4

80X

3

4.5X

45X

4.9

67.5X

3.6

90X

2.7

5.2 Auxiliary objective standard(optional)

Magnification

Working

distance(mm)

Magnification

Working

distance(mm)

0.3X

287

0.75X

117

0.4X

217

1.5X

47

0.5X

177

2X

26

Working distance is fixed regardless of the magnification factor.
Total mag.= Zoom mag. X Eyepiece mag. X Auxiliary objective mag.

Diameter of field of view(mm)=

Field number of eyepiece

Zoom mag.X Auxiliary objective mag.

5.3

Photo adapter mag.= Zoom mag.(X Auxiliary objective mag.)X Eyepiece mag.

5.4

Photo set zoom mag.= Zoom mag.(XAuxiliary objective mag.) X CTV mag .X C

type photo tube mag.

Summary of Contents for BS-3030 Series

Page 1: ...roscope BS 3030 series To ensure the safety and obtain optimum performance and familiarize yourself fully with the use of this microscope we recommend that you read this manual thoroughly before opera...

Page 2: ...using arm 4 3 3 Set the specimen slide 4 3 4 Adjust the specimen slide 4 3 5 Adjust the interpupillary distance 5 3 6 Mount and remove the optional eyepiece micrometer 5 3 7 Use auxiliary objective 5...

Page 3: ...will be damaged 6 When use photo set to capture image please ensure the stability of microscope make sure the main body inclined less than 3 7 When use camera with C mount the camera sensor size shou...

Page 4: ...2 1 Nomenclature Eyepiece Head lock screw Zoom control knob Focusing Head Base Clip Black and white work board Lock screw C mount Focusing ring PK mount...

Page 5: ...d ensure that all connections has clean surface the installation should be taken to avoid the surface of the lens was dirty or scratched C type camera C type mount PK mount Eyepiece Head Head lock scr...

Page 6: ...ket from slipping down by its weight during the observation Fig 2 Set the specimen slide 1 Set the specimen on the center of stage plate If necessary clamp the slide with the clips 2 Turn on the light...

Page 7: ...Auxiliary objective has long working distance When use 0 5x auxiliary objective release the lock screw on the arm by a 4mm Allen key move the focus arm up and fixed in the up screw hole Fig 6 0 75x au...

Page 8: ...4 2 Operation Fig 10 Fig 11 Fig 9 2 1 Adjust the brightness of the bottom light or top light Turn the adjustable light knob knob control top light knob control bottom light along the clockwise the br...

Page 9: ...3X 30X 7 3 45X 5 3 60X 4 4X 40X 5 5 60X 4 80X 3 4 5X 45X 4 9 67 5X 3 6 90X 2 7 5 2 Auxiliary objective standard optional Magnification Working distance mm Magnification Working distance mm 0 3X 287 0...

Page 10: ...not correct Readjust the diopter Focus is not correct Readjust the focus 6 The image on the monitor is not clear when the focusing knob is turned The focus of video is not correct Readjust the focus o...

Reviews: