Table 2-3 V-Station 4G and V-Flex 4G Power Requirements
Power Requirement:
12 watts
Input Voltage Range: 12-24.0 VDC
Peak Current (12 VDC) 1 A
Peak Current (24 VDC) 500 mA
Table 2-4 V-Station 4G Extreme Power Requirements
Power Requirement
12 watts
Input Voltage Range
12-24.0 VDC @ 3 Amps
Peak Current (12 VDC) 1 A
Peak Current (24 VDC) 500 mA
Cooler Module
12 to 24VDC @ 10Amps
Most power supplies on the market today provide good input and output isolation.
However, power supplies which do not provide isolation (or have high leakage
capacitance), coupled with accidental AC power line interchanges, present serious
ground fault problems for installers. With a ground fault, the signal reference between
subsystems may be 115 VAC apart. If these subsystems are interconnected, the large
potential difference can cause equipment damage or personal injury. L-1 Identity
Solutions recommends using a dedicated regulated DC power supply.
All factory-supplied power supply assemblies are either switching or regulated linear