5.  Specifications 

The  unit  is  designed  for  operation  in  cold  rooms,  incubators  and  closed  la-

boratory  rooms  at  ambient  temperature  from  +4

°C  to  +40°C  in  a  non-condensing 

atmosphere 

and  maximum  relative  humidity  80%  for  temperatures  up  to  31°C 

decreasing linearly to 50% relative humidity at 40°C.

 

5.1. 

Number of detection channels .....................................................................  4 

5.2. 

Detector  ................................................................................. Photomultiplier 

5.3. 

First Channel FAM    

 

excitation wavelength  ...................................................................................... 460 nm 

 

emission wavelength  ....................................................................................... 515 nm 

5.4. 

Second Channel JOE, HEX, R6G  

 

excitation wavelength  ...................................................................................... 532 nm 

 

emission wavelength  ....................................................................................... 570 nm 

5.5. 

Third Channel ROX  

 

excitation wavelength  ...................................................................................... 570 nm 

 

emission wavelength  ....................................................................................... 610 nm 

5.6. 

Fourth Channel CY-5  

 

excitation wavelength  ...................................................................................... 630 nm 

 

emission wavelength  ....................................................................................... 670 nm 

5.7. 

Rotor capacity  

 

R-036 ................................................................................................ 36 x 0.5 ml tubes 

 

R-048  ............................................................................................... 48 x 0.2 ml tubes 

5.8. 

Measurement time  

 

(rotor R-036, 1 channel ) ......................................................................... 55 s 

5.9. 

Excitation source  ................  Light diode (Luxeon), through interference filter 

5.10.  Interference filter transmission spectrum half-width  ............................... 7 nm 
5.11.  Number of measurements per sample in detection mode  ..................... 2000 
5.12.  Interface cable  ........................................................................................ USB 
5.13.  Input voltage  ......................................................................... 230V; 50/60 Hz 
5.14.  Power consumption, no more than  ........................................................ 30 W 
5.15. 

Dimensions 400х250х190 mm 

5.16.  Weight* ................................................................................................. 8.5 kg

 

 

Biosan is committed to a continuous  program of improvement and reserves 

the  right  to  alter  design  and  specifications  of  the  equipment  without  additional 
notice. 

 

Accurate within ±10%. 

Summary of Contents for Automatic Luminescence Analyser ALA1/4

Page 1: ......

Page 2: ...2...

Page 3: ...3 Contents 1 Safety Precautions 4 2 General Information 5 3 Getting started 6 4 Operation 7 5 Specifications 8 6 Maintenance 9 7 Warranty and Claims 10...

Page 4: ...use an ungrounded extension lead Disconnect the unit from electric circuit before moving Switch the unit off and disconnect the power cord plug from power socket to disconnect the unit from electric...

Page 5: ...on The close tubes method ensures a biosafety conditions in the DNA diagnostic Labs The product consists of the flowing main parts A rotor with tubes sockets fixed on the motor axis Optical module Mic...

Page 6: ...r 0 5 ml tubes 1 pce Rotor for 0 2 ml tubes 1 pce Data Cable 1 pce Software installation disc 1 pce Software installation manual 1 copy Software operating manual 1 copy Software Quick Start 1 copy Ope...

Page 7: ...ation Install the rotor into the analyser The positioning pin on the base inside the unit must match into the opening in the rotor Secure the new rotor carefully and turning the latch tightly Caution...

Page 8: ...length 570 nm emission wavelength 610 nm 5 6 Fourth Channel CY 5 excitation wavelength 630 nm emission wavelength 670 nm 5 7 Rotor capacity R 036 36 x 0 5 ml tubes R 048 48 x 0 2 ml tubes 5 8 Measurem...

Page 9: ...personnel 6 3 Standard ethanol 75 or other cleaning agents recommended for cleaning of laboratory equipment can be used for cleaning and decontamination of the unit 6 4 Fuse replacement Disconnect fro...

Page 10: ...ck availability of extended warranty 7 3 Warranty covers only the units transported in the original package 7 4 If any manufacturing defects are discovered by the Customer an unsatisfac tory equipment...

Page 11: ...11...

Page 12: ...SIA Biosan Ratsupites 7 build 2 Riga LV 1067 Latvia Phone 371 6742 6137 Fax 371 6742 8101 http www biosan lv Edition 2 01 October 2015...

Reviews: