1.  Safety Precautions 

The following symbol means: 

 

Caution:

 

Make  sure  you  have  fully  read  and  understood  the  present 
Manual  before  using  the  equipment.  Please  pay  special  at-
tention to sections marked by this symbol. 

GENERAL SAFETY 

 

Use only as specified in the operating manual provided. 

 

Save the unit from shocks and falling.  

 

After transportation or storage, keep the unit under room temperature for 2-
3 hrs. before connecting it to the electric circuit.  

 

Before  using  any  cleaning  or  decontamination  methods  except  those  rec-
ommended  by  the  manufacturer,  check  with  the  manufacturer  that  the  pro-
posed method will not damage the equipment. 

 

Do not make modifications in design of the unit.  

 
ELECTRICAL SAFETY 

 

Connect  only  to  electric  circuit  with  voltage  corresponding  to  that  on  the 
serial number label.  

 

Ensure that the switch and plug are easily accessible during use. 

 

Do  not  plug  the  unit  into  an  ungrounded  power  socket,  and  do  not  use  an 
ungrounded extension lead.  

 

Disconnect  the  unit  from  electric  circuit  before  moving.  Switch  the  unit  off 
and disconnect the power cord plug from power socket to disconnect the unit 
from electric circuit. 

 

It  is  the  user’s  responsibility  to  carry  out  appropriate  decontamination  if 
hazardous material is spilt on or penetrates into the equipment. If liquid pen-
etrates into the unit, disconnect it from electric circuit and have it checked by 
a repair and maintenance technician. 

 

Do not operate the unit in premises where condensation can form. Operating 
conditions of the unit are defined in the Specifications section. 

 
DURING OPERATION  

 

Do not operate the unit in environments with aggressive or explosive chemi-
cal  mixtures.  Please  contact manufacturer  for possible  operation  of  the  unit 
in specific atmospheres. 

 

Do not operate the unit if it is faulty or was installed incorrectly. 

 

Do not use outside laboratory rooms.  

 

Do not operate the unit while the lid is open. 

 
BIOLOGICAL SAFETY 

 

It  is  the  user’s  responsibility  to  carry  out  appropriate  decontamination  if 
hazardous material is spilt on or penetrates into the equipment. 

Summary of Contents for Automatic Luminescence Analyser ALA1/4

Page 1: ......

Page 2: ...2...

Page 3: ...3 Contents 1 Safety Precautions 4 2 General Information 5 3 Getting started 6 4 Operation 7 5 Specifications 8 6 Maintenance 9 7 Warranty and Claims 10...

Page 4: ...use an ungrounded extension lead Disconnect the unit from electric circuit before moving Switch the unit off and disconnect the power cord plug from power socket to disconnect the unit from electric...

Page 5: ...on The close tubes method ensures a biosafety conditions in the DNA diagnostic Labs The product consists of the flowing main parts A rotor with tubes sockets fixed on the motor axis Optical module Mic...

Page 6: ...r 0 5 ml tubes 1 pce Rotor for 0 2 ml tubes 1 pce Data Cable 1 pce Software installation disc 1 pce Software installation manual 1 copy Software operating manual 1 copy Software Quick Start 1 copy Ope...

Page 7: ...ation Install the rotor into the analyser The positioning pin on the base inside the unit must match into the opening in the rotor Secure the new rotor carefully and turning the latch tightly Caution...

Page 8: ...length 570 nm emission wavelength 610 nm 5 6 Fourth Channel CY 5 excitation wavelength 630 nm emission wavelength 670 nm 5 7 Rotor capacity R 036 36 x 0 5 ml tubes R 048 48 x 0 2 ml tubes 5 8 Measurem...

Page 9: ...personnel 6 3 Standard ethanol 75 or other cleaning agents recommended for cleaning of laboratory equipment can be used for cleaning and decontamination of the unit 6 4 Fuse replacement Disconnect fro...

Page 10: ...ck availability of extended warranty 7 3 Warranty covers only the units transported in the original package 7 4 If any manufacturing defects are discovered by the Customer an unsatisfac tory equipment...

Page 11: ...11...

Page 12: ...SIA Biosan Ratsupites 7 build 2 Riga LV 1067 Latvia Phone 371 6742 6137 Fax 371 6742 8101 http www biosan lv Edition 2 01 October 2015...

Reviews: