B. USER GUIDE > 3. OPERATING AND MAINTENANCE RECOMMANDATIONS
PAGE
38 / 49
Installation and User guide – MONOBLOCK Systems – 06-12-2016
Checking of the treated effluent at the Secondary Compartment outlet
To be done annually
Treated effluent discharge at the outlet of the MONOBLOCK :
No stagnant water should be noticed at the outlet of the system. Water should continuously flow
by gravity.
Check if any blockage at the outlet pipe.
Alarm : in case of a malfunction :
A visual alarm is installed on top of the MONOBLOCK. The float will pop-up if the system is overloaded
with liquid.
In normal use, the warning float is in the lower position at ground level.
If there is a problem the increase in the water level causes the float to rise. Should this occur,
Check if any blockage at the outlet pipe.