3.3.5 Boiler Operation Mode Selection 

This function is intended for selecting one of three modes of boiler operation.   
І. House Heating: ON/OFF 
When activating this mode the heating system will give priority to heating the line of 

the central heating pump.

 

ІІ. Parallel Pumps: ON/OFF 
When  activating  this  mode  the  heating  system  equally  distributes  the  heat  carrier  to 

heating lines depending on temperature ranges assigned by the user.    

ІІІ. Summer Mode: ON/OFF 
When activating this mode the heating system will be functioning only to maintain the 

temperature of the hot water supply pump line.    

 

3.3.6 Pumps 

This  function  allows  setting  up  the  temperature  value  whereby  the  Controller  will 

switch on the central heating pump or hot water supply pump to supply heat carrier to this or 
other  system.  Hysteresis  value  in  this  case  is  the  value  that  shows  difference  between  the 
preset temperature of pump switch on and boiler temperature dropping to the value whereby 
the Controller will switch off the Central Heating pump. 

а.) Pump Switch on Temperature: changes within the range of 30–95°С 
b.) Pump Hysteresis: changes within the range 1–10°С. 
 

3.3.7 Adjuster Menu 

This function allows adjusting basic parameters of the Controller’s program. 
3.3.7.1 Screw feeder alarm switch on temperature: 50–95°С. 
This  parameter  ensures  safe  operation  of  the  boiler  and  protects  fuel  bunker  from 

burn-up. In case of temperature rise on screw sensor higher than the preset one in this item, 
the Controller moves to the emergency mode (burn-up in the feeder). The fan switches off, 
the screw feeder switches on for the time period set up in Item  7.2. to push out burning fuel 
from the bunker.   

3.3.7.2 Screw feeder operation during alarm: 1–20 min. 
This  parameter  is  intended  for  setting  up  screw  feeder  operation  time  for  fuel  off-

loading during its burn-up. If, in a certain time period the temperature on the sensor does not 
drop up to the appropriate one, the off-loading cycle will be repeated.   

3.3.7.3 Factory Settings: factory reset NO/YES 
This function allows carrying out factory reset. 
Once factory reset is done it is required to set up the Controller’s parameters again. 
3.3.7.4 Sensors Switch off: 
І. Hot Water Supply Sensor: on/off 
This function allows deactivating control of hot water circuit in systems where it is not 

Summary of Contents for AIR BIO

Page 1: ...1 OPERATION MANUAL FOR AIR BIO ELECTRONIC CONTROL UNIT FOR SOLID FUEL BOILER Kharkov city...

Page 2: ...and fuel supply system AIR BIO delivery set includes 1 Network cable with plug tip 2 m long 1 ea 2 Wire for hooking up the fan with connector 0 5m long 1 ea 3 Wire for hooking up the pump 2m long 2 ea...

Page 3: ...3 Picture1 AIR BIO Hookup Diagram Picture 2 AIR BIO Hookup to Central Heating System Diagram...

Page 4: ...following advantages fuel significant saving because there is a capability to control burning intensiveness capability to adjust Hot Water Supply temperature capability to adjust Central Heating temp...

Page 5: ...nector in intended to protect the unit from short circuit Control unit screen displays the boiler operation mode When entering the MENU it displays the menu items and modes for setting up the respecti...

Page 6: ...tion time and interval time for fuel supply gear If boiler temperature is equal or higher than the preset temperature the Controller is in Standby mode Each Controller shall be adjusted individually d...

Page 7: ...in Display When supplying power and pressing Power button the Controller LCD display will show the main page User Menu with the following information STANDBY t CH XX YY t HW XY YX ZZ screw t QQ Pictur...

Page 8: ...ching off the pump check up of its operability 3 3 2 Firing ON OFF This function is intended for starting up the cold boiler When activating this function you transfer the boiler from Standby mode to...

Page 9: ...when the boiler is in the mode of gaining temperature up to the preset value Delivery time Value is set up from 1 to 250 sec Delivery time is selected in accordance with boiler capacity fuel type and...

Page 10: ...changes within the range of 30 95 b Pump Hysteresis changes within the range 1 10 3 3 7 Adjuster Menu This function allows adjusting basic parameters of the Controller s program 3 3 7 1 Screw feeder a...

Page 11: ...em 3 3 9 Boiler Hysteresis Range 1 10 You set up the value up to which heat carrier operation temperature goes down from the preset temperature whereby the Controller will transfer the boiler from Sup...

Page 12: ...temperature 45 9 Boiler hysteresis 5 5 PERFORMANCE DATA Parameter Description UoM Value 1 Power supply voltage V z 230 50 2 Max power input Watt 4 5 3 Automatic equipment operation temperature range 1...

Page 13: ...troller central heating systems shall be equipped with safety valves operating under pressure surge tanks protective systems to ensure there will be no water boiling in the central heating system it i...

Page 14: ...fire safety regulations and electrical safety requirements 2 Installation and adjustment of the Controller shall be carried out in the presence of the qualified specialist 3 It is recommended to insta...

Page 15: ...is not less than 10 years 2 LTD Bioprom Company Kharkov provides warranty for AIR BIO Controller for the period of 18 months from the date of sale but not longer than 24 months from the date of manuf...

Page 16: ...within the longer time period 9 TRANSPORTATION For the purpose of keeping maintaining the Controller integrity and proper functionality during transportation one shall follow all the transportation c...

Page 17: ...a www bioprom kh ua www bioprom ua www bioprom kharkov ua For all issues relating to warranty and post warranty service please feel free to contact us at the address of 126 1 Plekhanovskaya Str Kharko...

Page 18: ...18 For Notes...

Page 19: ...19 For Notes...

Page 20: ...oller is used in strict compliance with the manufacturer s specification Unit is checked by ______ Full Name ___________ signature Serial Number ______________________ Date Manufacturer s Signature an...

Reviews: