P L E A S E   R E A D   A N D   S AV E   T H E S E

I M P O RTA N T   S A F E T Y   I N S T R U C T I O N S

F E AT U R E S   -   O P E R AT I O N S

Converting to a Table Fan

An additional short pole (Q) is supplied which allows the 

fan to be converted into a table fan (see Figure 2). To 

change to this short pole, remove the fan head assembly 

from its position on top of the inner pole extension (N) 

and unscrew the T-shaped locking lever (U) at the base. 

Remove the outer pole (P), replace with the short pole 

(Q) and reassemble as detailed above.

OPERATING INSTRUCTIONS

1.  Set fan base on a dry, level surface.

2.    Plug cord into any standard 120 volt AC outlet. 

Please make sure the Speed Control Knob is in the 

OFF (O) position. Speed Control Knob is located on 

the Fan Motor Housing.

3.  The SPEED is adjusted by turning the Speed Control 

Knob to the desired setting, O-3-2-1.

4.   The OSCILLATION control knob is located on the top 

of the Fan Motor Housing. To start Oscillation, push 

Control knob down. To stop Oscillation, pull Speed 

Control Knob up.

ADJUSTMENT INSTRUCTIONS

Tilt-Adjustment

Follow these instructions to tilt the Fan Head for upward 

angle air movement.

1.  To change the tilting angle of the fan head, simply 

loosen the tilt-adjustment knob (K).

2.  Move the fan head to the desired angle and firmly 

tighten the tilt-adjustment knob to lock into place.

Height Adjustment

Follow these instructions to adjust the height of the fan.

1.  Turn the pole locking knob (O) counter-clockwise to 

loosen the pole.

2.  Adjust the pole to the desired height and firmly 

tighten the locking knob in a clockwise direction.

CLEANING/MAINTENANCE INSTRUCTIONS

Follow these instructions to correctly and safely care for 

your fan. Please remember:

REPLACEABLE FUSE

If your (5 Amp, 125 Volt) replaceable fuse blows, please 

order a new fuse at 1-800-253-2764. Follow the below 

instructions to replace the fuse on the plug.

User Servicing Instructions

1.  Unplug your fan. Grasp plug and remove from the 

receptacle or other outlet device. Do not unplug by 

pulling on cord.

2.  Open fuse cover, located on the top of the plug, by 

using your thumb or a flathead screwdriver to slide 

the cover down towards the prongs. 

  

Note:

 Ensure that fuse cover is completely open 

before attempting to remove fuse.

3.  Remove fuse carefully by using a small screwdriver 

to pry the fuse out of the 

compartment by the metal 

ends of the fuse (see Fig. 3).

4.  Place plug on a solid, flat 

surface. Insert new 5 Amp, 

125 Volt fuse into fuse 

compartment and use a 

small screwdriver to secure 

the metal ends of the fuse 

into the compartment.

 

Caution:

 Risk of fire. Replace fuse only with 5 Amp, 

125 Volt fuse.

5.  Slide fuse cover closed completely. If fuse cover is 

difficult to close, make sure fuse is secured in place 

completely by pressing down on metal ends of the 

fuse.

6.  Risk of fire. Do not replace attachment plug. Contains 

a safety device (fuse) that should not be removed. 

Discard product if the attachment plug is damaged.

ASSEMBLY INSTRUCTIONS

Assembly Time: 10-15 minutes.
Tools Required: Phillips head screw driver.

NOTE:

 Make sure you remove all contents from the 

package. Please check packaging materials for parts that 

could be required to operate your fan.

Base/Pole Assembly

You will need the base cover (R), weight (S), outer pole 

(P), washer (T) and T-shaped locking lever (U).

1.  Turn the base cover upside down and place the 

weight into the base cover.

2.  Insert the threaded end of the T-shaped locking lever 

into the hole of the washer, weight and through the 

base cover.

3.  While holding the base cover and weight with one 

hand vertically, connect the outer pole to the base, 

sliding the T-shaped locking lever into the bottom of 

the outer pole with your other hand.

4.  Turn the T-shaped locking lever clockwise to securely 

attach the pole to the base.

5.  Set the base on the floor, weight side down.

Fan Head Assembly

You are now ready to assemble the fan head.

1.  Remove the protective sleeve (G) and unscrew grill 

mounting nut (D) by turning counter-clockwise from 

the motor shaft (F). Position the rear grill (E) over 

the motor shaft (F), making certain that the vertical 

slots at the top and bottom of the rear grill fit over 

the prongs on the motor housing (H). Make sure that 

the carry handle is topmost on the motor assembly.

2.  Secure the rear grill (E) in its place using the rear 

grill mounting nut (D). Turn this nut clockwise and 

tighten firmly. 

3.  Loosen the securing screw (C) on side of the fan 

blade (B) to slide the fan blade onto the motor shaft 

(F) through the rear protrusion. Make sure the 

securing screw (C) rest on the notch (flat side) of 

motor shaft and tighten the screw (C).  

CAUTION:

 Avoid contact with sharp end of blades.

4.  Centre the front grill (A) by aligning the Bionaire

®

 

logo on the logo plate so that it is horizontal and 

parallel with the floor. Then place the bracket at the 

top over the front and rear grills with the hole on the 

bracket going through the center vertical bar. Fasten 

the other clips, making sure they go over both the 

front and rear grills.

5.   Replace grill screw and nut (V) and tighten with screw 

driver.

Final Assembly
NOTE:

 The fan head locking knob (L) is attached with 

the additional short pole (Q) when shipped.

1.  Slide the inner pole extension (N) up from the outer 

pole (P), first loosening the pole locking knob (O), to 

securely hold this position. Tighten the pole locking 

knob (O).

2.  Place the fan head assembly into this extension pole, 

inserting the fan’s head neck (M) into the pole 

opening.

3.  Add the fan head locking knob (L) to the hole in the 

fan head's neck (M), making sure holes are aligned, 

and tighten.

When using electrical appliances, basic safety precautions 

should always be taken including the following:
1.  Read all instructions before using this appliance.

2.  Use fan only for purposes described in the instruction 

manual.

3.  To protect against electrical shock do not immerse 

unit, plug or cord in water or spray with liquids and 

plug the appliance directly into a 120V AC electrical 

outlet.

4.  Close supervision is necessary when any appliance is 

used by or near children.

5.  Unplug from outlet when not in use, when moving 

fan from one location to another, before putting on 

or taking off parts and before cleaning.

6.  Avoid contact with moving parts.

7.  Do not operate in the presence of explosive and/or 

flammable fumes.

8.  To avoid fire hazard, NEVER place the cord under 

rugs or any parts near an open flame, cooking or 

other heating appliance.

9.  Do not operate any appliance with a damaged cord 

or plug after the appliance malfunctions, or has been 

dropped/damaged in any manner. Discard fan or 

return to an authorized service facility for 

examination and/or repair.

10. Do not run cord under carpeting.  Do not cover cord 

with throw rugs, runner, or similar coverings.  Do not 

route cord under furniture or appliances.  Arrange 

cord away from traffic area and where it will not be 

tripped over. 

11. The use of attachments not recommended or sold by 

the appliance manufacturer may cause hazards.

12. Do not let the cord hang over the edge of a table, 

counter or come in contact with hot surfaces or leave 

exposed to high traffic areas. 

13. Do not use outdoors.

14. To disconnect, grip plug and pull from wall outlet. 

Never yank on cord.

15. Always use on a dry, level surface. 

16. Do not operate fan until fully assembled with all 

parts properly in place.

17. This product is intended for household use ONLY and 

not for commercial or industrial applications.

18. 

WARNING:

 To reduce the risk of electrical shock 

and injury to persons, do not use in window.

19. 

WARNING:

 To reduce the risk of fire or electric 

shock, do not use this fan with any solid-state speed 

control device.

20. This product employs overload protection (fuse). A 

blown fuse indicates an overload or short-circuit 

situation. If the fuse blows, unplug the product from 

the outlet. Replace the fuse as per the user servicing 

instructions (follow product marking for proper fuse 

rating) and check the product. If the replacement 

fuse blows, a short circuit may be present and the 

product should be discarded or returned to an 

authorized service facility for examination and/or 

repair.

PLEASE READ AND SAVE 

THESE IMPORTANT SAFETY 

INSTRUCTIONS

F E AT U R E S   -   O P E R AT I O N S

C L E A N I N G / M A I N T E N A N C E

THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the 

other). To reduce the risk of electric shock, this plug is intended to fit in 

a polarized outlet only one way. If the plug does not fit fully in the 

outlet, reverse the plug. If it still does not fit, contact a qualified 

electrician to install the proper outlet. 

DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS 

SAFETY FEATURE IN ANY WAY.

Fuse cover

Fig. 3

Metal ends

Fuse

A

Fig. 1

B

C D

E

F

V

G H

I

M

O

P

Q

R

S

T

U

J

K

N

L

A  Front Grill

B.  Fan Blade

C.  Securing Screw

D.  Grill Mounting Nut

E.  Rear Grill

F.  Motor Shaft

G.  Plastic Sleeve

H.  Motor Housing

I.  Speed Control Knob

J.  Oscillation Control Knob

K.  Tilt Adjustment Knob

L.  Fan Head Locking Knob

M.  Fan Head's Neck

N.  Inner Pole Extension

O.  Pole Locking Knob

P.  Outer Pole

Q.  Additional Short Pole

R.  Base Cover

S.  Weight

T.  Washer

U.  T-Shaped Locking 

Lever

V.  Grill Screw and Nut

Base Cover

Additional Short Pole

Fig. 2

BSF1211C-MU_12EM1.indd   2

10/12/12   11:13 AM