Page 2: ...reas or featureless images 8 5 6 Unusual coloured dots in the SIAscan 9 6 Technical Details 10 6 1 System components 10 7 Care of MoleMate system Hardware 11 7 1 Use Windows to shutdown MoleMate PC 11...

Page 3: ...with the Cautions and Warnings section of the manual Important Contact SIAscans are intended to be used as an aid to diagnosis The user must understand the meaning and implications of SIAscans before...

Page 4: ...r varies spatially over the skin area Contact SIAscans provide information about Concentration The relative concentration of various skin components including pigment such as melanin blood and collage...

Page 5: ...eMate soft ware to view fully detailed SIAscans Important Do not disconnect the SIAscope V from the PC when it is scanning Important The SIAscope V contains no user serviceable parts Please contact As...

Page 6: ...Take care when packing unpacking the equipment The SIAscope V contains delicate com ponents which should not be subjected to undue forces Take care to store each item carefully in its appropriate car...

Page 7: ...ly optical matching fluid to the area of skin to be examined A single squirt from the applicator should be sufficient Additional matching fluid is available from Astron Clinica or your local distribut...

Page 8: ...bubbles particularly well To rectify the problem clean off the current layer of matching fluid apply a thinner layer and re take the scan 5 3 Consecutive scans contain a similar mark or spot A re occ...

Page 9: ...process the data collected In areas where this occurs the SIAscans contain bright dots which are easily distinguishable Such scans should be retaken If the dots appear consistently ensure that the sk...

Page 10: ...ate system consists of a SIAscope V The SIAscope V consists of a unit with a 11mm diameter sensing window It incorporates control but tons that allow navigation through the MoleMate software The SIAsc...

Page 11: ...tures between 10 C and 30 C Relative humidity between 30 and 80 The MoleMate hardware is not intended for use in areas of high electromagnetic radiation e g MRI and CT scanning rooms 7 4 Inappropriate...

Page 12: ...tely 3 seconds data collection 3 seconds data processing Data display format Processed data displayed as colour bitmaps SIAscans representing relat ive concentration and distribution of selected chrom...

Page 13: ...Electromagnetic Interference The SIAscope V has been tested to ensure full compliance with the relevant sections of EN60601 Electromagnetic Compatibility and Safety of Medical Electrical Equipment 13...

Page 14: ...ive to produce the highest quality products and welcome your feedback If you have comments or suggestions about MoleMate please do not hesitate to contact us If you have a technical query please conta...

Page 15: ...clean Clean the SIAscope V window with an Isopropyl wipe SIAscope V will not connect Check that the SIAscope V has been connected properly to a USB 2 0 port Try connecting to another USB 2 0 port Drop...

Page 16: ...hours 9 00 am and 5 00 pm AEST Australian Eastern Standard Time excluding public holidays to help with any issues relating to the installation and operation of the MoleMate Product Astron Clinica can...

Page 17: ...e excluding public holidays to help with any issues relating to the installation and operation of the MoleMate Product Astron Clinica can be contacted by phone on 1300 889 340 outside Australia 61 7 3...

Page 18: ...for incidental or consequential damages in con nection with the furnishing performance or use of this material All rights reserved Reproduction adaptation or translation of this document is prohibite...

Page 19: ...A Revisions Table A 1 Revisions Revision No Revision Description Date Revision 0 1 First draft composed 05 07 2006 Revision 0 2 Final version for printing 01 09 2006 19...

Reviews: