EN-3

EN

Component drawing

2

1

2

1.3 Installing the ventilation pipe

The seat top is provided with a Ø 110 mm hole for the ventilation 

pipe. Install the sliding sleeve (part 3) with the Compostmixer 

in the hole. Insert the ventilation pipe (part 2) only about 10 cm 

inside the sliding sleeve (part 3).     
Route the ventilation pipe without bends from the toilet unit over 

the roof ridge along the wall either passing the eaves or through 

the roof. Seal the lead-through on the roof using sealant suitable 

for the roofing material. The sealant can be purchased from any 

hardware store.

If you have to make some bends, take note that the curvature 

of such bends must not exceed 33 degrees. Any bends in the 

ventilation  pipe  impede  natural  ventilation,  causing  odour  and 

moisture problems.

Populett 200:

 Saw off the sleeve from one end of the ventilation 

pipe (part 2). Put the pipe cap (part 1) on the ventilation pipe 

to ensure that rainwater cannot enter the toilet. It is possible to 

improve the ventilation and the evaporation of moisture using the 

Biolan Wind Fan (see Accessories on page EN-8), available as 

an option.

Populett 300:

 Saw off the sleeve from one end of the ventila-

tion pipe (part 2). Install the Wind Fan on the ventilation pipe. 

Remove the 75 mm reduction sleeve from the Wind Fan before 

installation. 

Any bends in the ventilation pipe impede natural 

ventilation, causing odour and moisture problems.

3

6
5

13

11

12

8

4

8 9 10

19

17

16

13

11

12

20

18

14

15

Summary of Contents for POPULETT 200

Page 1: ...BIOLAN POPULETT 200 and 300 Instructions for installation use and maintenance 70578600 70578800 EN 05 2012...

Page 2: ...1000 mm...

Page 3: ...uid canister EN 6 2 8 Cleaning EN 6 3 Post treatment and use of the compost EN 6 3 1 Need for post composting EN 6 3 2 Using cover soil EN 7 3 3 Maturing cover soil to compost soil EN 7 3 4 Testing th...

Page 4: ...osting procedure You can install the Populett in an existing toilet building taking into ac count that the structure of the building must be modified in order to en able correct positioning of the toi...

Page 5: ...urvature of such bends must not exceed 33 degrees Any bends in the ventilation pipe impede natural ventilation causing odour and moisture problems Populett 200 Saw off the sleeve from one end of the v...

Page 6: ...ill also come out of the unit It is drained off from the unit together with the urine If the Populett is set to separate urine more liquid will be created for collection and treatment Take this into a...

Page 7: ...does not compost such as debris sanitary towels chemicals lime detergents washing water ash cigarette butts matches 2 4 Using bulking material and the Compostmixer Every time after the toilet is used...

Page 8: ...ust water the area carefully after the application to avoid early blight Fertilising in the autumn is not recommended so as not to disturb the preparation of perennial plants for winter The recommende...

Page 9: ...ter soluble nutrients In a couple of months the compost matures into compost soil of a dark brown colour and aggregate struc ture from which source substances except for bigger wood splinters can no l...

Page 10: ...Suotis is a biochemical seep liquid filter for a dry toilet The de vice cleans up the seep liquid so that it can be conducted directly into the ground It is not suitable for separated urine The filter...

Page 11: ......

Page 12: ......

Reviews: