background image

EN-2

EN

Com-

ponent

Part name

Number

Material

1

pipe cap

18780250

PE

2

ventilation pipe with sleeve Ø 110 x 3.4 - 1000 mm

28780120

PE

3

sliding sleeve

18780200

PE

4

thermal seat Pehvakka

70578500

EPP

5

inlet air valve body and

18792901

PP

6

inlet air valve cover

PE

7

top (Populett 200 / 300) 

17780020

PE

8

separating flap 200 x 220 mm  

18780090

PVC - soft- 50

9

separating net 200 x 220 mm  

18780110

PE

10

convex sticker Biolan 

27710360

PE

11

locking rubber for the top

19734110

EPDM

12

locking rubber washer

18726140

PE

13

locking rubber screw

20010012

ZN

14

flexible liquid pipe, black 32 mm

28578010

PE

15

lead-through rubber 30/40

19780050

EPDM

16

transport wheels 

29780923

RST+PP+EPDM

17

retainer clip, with cap

20700004

ZN

18

tank 200 (Populett 200) 

17780010

PE

19

tank 300 (Populett 300) 

17782010

PE

Accessory
20

Cover for replacement tank  

17780190

PE

In addition to the components illustrated in the component drawing, Populett 200 and 300 also include:

Compost and Toilet Bulking Material, 40 l  

70562100

package PE

intermediate bottom plate  

17780030

PE

  

holder strap for intermediate bottom 700 x 30 mm

20780040

nylon

 

Populett 200, separating pipe Ø 75 x 2.7 - 550 mm 

28780080

PE

Populett 300, separating pipe Ø 75 x 2.7 - 890 mm  

28710240

PE

holder strap for liquid pipe 200 x 30 mm  

20780100

nylon

template 

27780170

paper

user manual Finnish/Swedish

27780180

paper

user manual in 10 languages (export products only)

27780190

paper

Compostmixer

70575200

In addition to the components illustrated in the component drawing, Populett 300 also includes: 

 

Wind Fan 

70572500

Component list

1. Planning and installation 

When locating the Biolan Populett, provide sufficient space for use and 

maintenance of the toilet, for installation of the toilet through the wall of 

the toilet building, and for routing of the ventilation pipe. How the seep 

liquid or the seep liquid and urine shall be conducted into the tank or rel-

evant treatment facility also needs to be taken into account. The unit can 

be placed directly on sufficiently firm ground. Before building the toilet, 

plan the access route required for maintenance behind the toilet and for 

the post-composting procedure.
You can install the Populett in an existing toilet building taking into ac-

count that the structure of the building must be modified in order to en

-

able correct positioning of the toilet unit. When planning a new toilet 

building, take into account the space requirement of the unit. See the 

dimension drawing.

1.1 Technical specifications

• 

depth of the seat part inside the toilet building about 55 cm

• 

width of the seat part inside the toilet building about 89 cm

• 

height of the seat part 51 cm

•  overall height: Populett 200 93.5 cm, Populett 300 128.5 cm

•  volume  of  the  tank:  Populett  200  about  200  l,  Populett  300  about 

300 l

•  weight: Populett 200 about 27 kg, Populett 300 about 30 kg

• 

external diameter of the liquid pipe 32 mm

•  external diameter of the ventilation pipe 110 mm, length about 230 

cm

1.2  Placing in the toilet space

Install the Biolan Populett through the wall and the floor so that the top 

of the tank (part 7) will serve as the seat ring. The body, which serves as 

a tank for the toilet waste, is supported on the ground and at the same 

time it supports the seat part. The distance from the toilet floor to the 

ground surface must be 37 cm for Populett 200, and 71.5 cm for Popu

-

lett 300. Thus the toilet unit will be supported both by the ground and the 

edge of the toilet floor.
Make a smooth and durable bed for the toilet unit, such as, for exam

-

ple, a gravel bed, covered by film-faced plywood or a concreted bottom 

structure.

While creating the openings and bottom structure of the building, put the 

toilet unit occasionally in place so as to find out where the openings still 

need to be reworked. Using the sawing template and the dimensions 

provided as an aid, saw a suitable opening for the toilet in the floor and 

in  the  wall.  Depending  on  the  manufacturing  technique,  the  size  and 

shape of the tank vary slightly. This means that you may have to enlarge 

the hole a bit or the seam of the floor and the tank will not be completely 

tight. Avoid,  however,  making  the  openings  too  large,  because  a  too 

wide chink between the toilet building and the toilet unit is not a good 

thing. Cover the space between the rear wall of the toilet building and 

the toilet unit with a strip (Fig.1).
Put the Populett in place without the wheels and shaft. Put the transport 

wheels (part 15) in place only for moving the toilet unit.

Summary of Contents for POPULETT 200

Page 1: ...BIOLAN POPULETT 200 and 300 Instructions for installation use and maintenance 70578600 70578800 EN 05 2012...

Page 2: ...1000 mm...

Page 3: ...uid canister EN 6 2 8 Cleaning EN 6 3 Post treatment and use of the compost EN 6 3 1 Need for post composting EN 6 3 2 Using cover soil EN 7 3 3 Maturing cover soil to compost soil EN 7 3 4 Testing th...

Page 4: ...osting procedure You can install the Populett in an existing toilet building taking into ac count that the structure of the building must be modified in order to en able correct positioning of the toi...

Page 5: ...urvature of such bends must not exceed 33 degrees Any bends in the ventilation pipe impede natural ventilation causing odour and moisture problems Populett 200 Saw off the sleeve from one end of the v...

Page 6: ...ill also come out of the unit It is drained off from the unit together with the urine If the Populett is set to separate urine more liquid will be created for collection and treatment Take this into a...

Page 7: ...does not compost such as debris sanitary towels chemicals lime detergents washing water ash cigarette butts matches 2 4 Using bulking material and the Compostmixer Every time after the toilet is used...

Page 8: ...ust water the area carefully after the application to avoid early blight Fertilising in the autumn is not recommended so as not to disturb the preparation of perennial plants for winter The recommende...

Page 9: ...ter soluble nutrients In a couple of months the compost matures into compost soil of a dark brown colour and aggregate struc ture from which source substances except for bigger wood splinters can no l...

Page 10: ...Suotis is a biochemical seep liquid filter for a dry toilet The de vice cleans up the seep liquid so that it can be conducted directly into the ground It is not suitable for separated urine The filter...

Page 11: ......

Page 12: ......

Reviews: