10
9
For more information about BioEngergiser Products visit our website at: www.globalproductcom
For more information about BioEngergiser Products visit our website at: www.globalproductcom
8
TROUBLESHOOTING
Device will not
turn on.
Power turns
off too soon
Power turns off
while using
massager
It is difficult to
attach Gel pad
to the skin
Adhesive
surface of Gel
pad is not
sticky
It is difficult to
feel stimulation
The skin turns
red or the skin
feels irritated
Batteries inserted in wrong direction.
The adapter is not plug well into device
properly.
Gel pads not attached correctly to the skin.
if you are using the batteries operation, then
the batteries weak/exhausted.
Treatment period of 30 minutes is over and
power turns off automatically.
if you are using the body massage, the
electrode gel pad may be broken
Transparent film not peeled off
Gel pad applied immediately after washing
Use of Gel pad during perspiring
Gel pad washed too long and/or too frequently
Gel pads stored under high temperature, high
humidity, direct sunshine
You sole is too dry, not moisture enough
Your sole is not placing on the foot pedal
properly
Gel pads not attached correctly to the skin
Gel pads overlap each other
Electrode cord not connected correctly
Applied intensity too weak
Adhesive surface of Gel pads dirty or dry
Adhesive surface of Gel pads damaged
Adhesive surface of Gel pad damaged.
The gel pads get dirty and lost their
adhesive/stickiness.
Attach Gel pads correctly to the skin.
Fit 4 new identical 1.5V alkaline batteries type AA.
Restart treatment or turn off the massager.
Replace electrode gel pad
Peel off film on the adhesive surface of Gel pad
Sufficiently dry Gel pad
Replace Gel pad
Replace Gel pad or clean the gel pad with a small
drop of water onto the sticky side of the
electrode pad and rub into the surface
Leave Gel pad in freezer for overnight
put some water to your sole to moisture your
sole.
Ensure both of your sole are placed on each
pedal properly. each
Attach Gel pad firmly to the skin
Reattach Long Life pads with no overlap
Connect electrode cord correctly
Increase the intensity by turning the dial switch
Wash adhesive surface of Gel pads softly with your
fingertips for about 3 seconds under slow running
water
Replace Gel pads
Insert batteries in correct direction or check the
battery is in full power.
check the connection of the adapter jack is in
well connected. And also the DC adapter with
well connecting to the main socket.
Troubleshooting & Maintenance
Clean the device with a soft, damp cloth but make sure squeeze a cloth dry and to clean the foot pedal area. Store the
Electrode Gel pads on the plastic pad protectors provided.
Keep the whole set of product clean and storage in a dust free and dry location under the condition
Hygiene
Storage
After using the product
-10°C to 60°C, 10% to 95% RH
-5°C to 50°C, 30% to 90% RH
Storage temperature and humidity
Operating temperature and humidity
Problem
Rectification
Cause
TECHNICAL SPECIFICATIONS
Model no. of Adapter
GPE038-060050-3
Adaptor Input
AC 100-240V~50-60Hz 0.1A
Adapter Output
DC 6V 500mA 3.0W
Battery life
>350 minutes
Frequency Generation
Approx. 10 Hz to 55.56 Hz
Power Consumption
1.05 W
Maximum Output Voltage
U <54.8V (during 1 kΩ load)
Maximum Output Current
I < 910 μA (during 1 kΩ load)
Operating Temperature And Humidity
-5°C to 50°C, 30%to 90% RH
Storage Temperature And Humidity
-10°C to 60°C, 10% to 95% RH
Main Unit Dimensions
338(L) x 324 (W) x 48(H) mm
Weight Approx.
950 g
Package Contents
Quantity Parts
*Batteries are not included
1
Circulation Reviver
TM
1
AC/DC Adaptor
1
Remote Control
2
Cable Wire for Electrode Gel Pads
4
Electrode Gel Pads
2
Plastic Gel pads protector
1
Instruction Manual
Accessories :
Only use original accessories. If user use of other
parts or materials can degrade minimum safety.
Check that the contents of the delivery are
complete.
Product Name
Circulation Reviver
TM
Model
BE130
6V DC or 4x1.5V batteries type AA* for the main unit
2x1.5V batteries type AAA* for the remote control
Power Supply
Supplier of Adaptor
Golden Profit Electronics Ltd.
ENGLISH
Summary of Contents for Circulation maxx Reviver BE130
Page 1: ...1 Handleiding So simple to use it s designed with you in mind...
Page 2: ......
Page 12: ......
Page 23: ...1 Instruction Manual CB 200 EU Circulator...
Page 33: ...33 33 F 11...
Page 34: ...34 F 12...
Page 35: ...35 35 F 13...
Page 55: ...55 55 D 33...
Page 56: ...56 D 34...
Page 57: ...57 57 D 35...
Page 68: ......