Manuale d’uso e tecnico/User and service manual – PiastraPF100 (da/from sn 411717683) 

 

 
 

Bio Optica Milano S.p.A. 

 via San Faustino 58 

 I-20134 Milano 

Tel. +39 02.21.27.13.1 

 Fax Acquisti/39 02.21.54.155 

Fax Assistenza/Contabilità +39 02.26.41.74.48 

 Fax V39 02.21.53.000 

Revisione 170712 del 12/07/17 

Pagina 17 di 19 

 
 

 

 
 
 

MAIN COMPONENTS 

 

 
 

CODE 

DESCRIPTION 

QUANTITY 

37-AR09E2F6A 

6 AMPERE WIRE FILTER 

37-0105.1 

PLATE FRAME 

37-1040/N THERMOREGULATOR  1 

37-SONDAPF 

PROBE FOR THERMOREGULATOR 

37-RELE1040-25 RELAY 

37-129-432 

GREEN WATERPROOF SWITCH 

37-1023 

RUBBER FEETS 

37-1045 

POWER SUPPLY CABLE 

37-1099/1.0 

UPPER CHASSIS 

37-1099/2.0 

LOWER BASE 

37-1099/3.0 

BASIN 1 

37-1099/6 

AGAINSTBASIN 1 

37-1099/7 

ALUMINIUM PLATE 

37-1099/8 

COPPER PLATE 

37-1099/10 

STAINLESS SUPPORT FOR THERMOREGULATOR 

 

 
 
 
 
 
 
 
 
 

Summary of Contents for Piastra Fredda PF100

Page 1: ...7683 Bio Optica Milano S p A via San Faustino 58 I 20134 Milano Tel 39 02 21 27 13 1 Fax Acquisti Export 39 02 21 54 155 Fax Assistenza Contabilit 39 02 26 41 74 48 Fax Vendite 39 02 21 53 000 Revisio...

Page 2: ...Tecnica Tel 02 21271310 6 La sicurezza elettrica di questo strumento assicurata soltanto quando lo stesso correttamente collegato ad un efficace impianto di messa a terra come previsto dalle vigenti n...

Page 3: ...12 07 17 Pagina 3 di 19 12 Simboli grafici presenti in etichetta posizionata di fianco alla presa di alimentazione dello strumento Simbolo per NUMERO DI CATALOGO Simbolo per NUMERO DI SERIE Simbolo pe...

Page 4: ...inclusi in paraffina Caratteristiche dimensionali Dimensioni LxPxH 500x550x290 mm Dimensioni superficie raffreddante LxP 400x270 mm Peso 30 Kg Collegamenti elettrici Alimentazione 230V 50 60Hz Potenza...

Page 5: ...ristiche tecniche Funzionamento Unico tasto ON OFF per accensione e spegnimento Temperatura impostabile fino a max 20 C gestita da termoregolazione interna Precisione di lettura 0 5 C Procedura per l...

Page 6: ...atura effettiva di lavoro corrisponder a quella impostata 6 Riposizionare lo sportello nell apposita sede e serrare tutte le viti 7 Posizionare la macchina nella posizione iniziale Installazione Posiz...

Page 7: ...strumento non necessita di sterilizzazione in quanto non previsto il trattamento di campioni freschi ma solo di campioni istologici fissati e inclusi in paraffina Manutenzione La manutenzione periodi...

Page 8: ...di 19 PRINCIPALI COMPONENTI CODICE DESCRIZIONE QUANTITA 37 AR09E2F6A FILTRO RETE 6 AMPERE 1 37 0105 1 CORNICE 1 37 1040 N TERMOREGOLATORE 1 37 SONDAPF SONDA PER TERMOREGOLATORE 1 37 RELE1040 25 RELE 1...

Page 9: ...om sn 411717683 Bio Optica Milano S p A via San Faustino 58 I 20134 Milano Tel 39 02 21 27 13 1 Fax Acquisti Export 39 02 21 54 155 Fax Assistenza Contabilit 39 02 26 41 74 48 Fax Vendite 39 02 21 53...

Page 10: ...17683 Bio Optica Milano S p A via San Faustino 58 I 20134 Milano Tel 39 02 21 27 13 1 Fax Acquisti Export 39 02 21 54 155 Fax Assistenza Contabilit 39 02 26 41 74 48 Fax Vendite 39 02 21 53 000 Revisi...

Page 11: ...ument can be guaranteed only if it is correctly connected to an efficient earth circuit as indicated by current electrical safety regulations It is necessary to check this fundamental safety prerequis...

Page 12: ...53 000 Revisione 170712 del 12 07 17 Pagina 12 di 19 11 Graphic symbols indicated on the label positioned near the instrument s power supply socket Symbol for CATALOGUE NUMBER Symbol for SERIAL NUMBER...

Page 13: ...g of histological samples included in paraffin Dimensional features Dimensions WxDxH 500x550x290 mm Cooling surface dimensions WxD 400x270 mm Weight 30 Kg Electrical connections Power supply 230V 50 6...

Page 14: ...0712 del 12 07 17 Pagina 14 di 19 Technical features Working Single key ON OFF for ignition and switching off Temperature programmable up to max 20 C managed by internal thermostatic temperature contr...

Page 15: ...a few minutes the actual working temperature will be the same as that set 6 Replace the door in the seat and tighten all the screws 7 Place the machine in its original position Installation Position...

Page 16: ...gents Do not use abrasive products or acids in order to avoid ruining the varnished or plastic parts The instrument does not need to be sterilized because is not expected the treatment of fresh sample...

Page 17: ...Pagina 17 di 19 MAIN COMPONENTS CODE DESCRIPTION QUANTITY 37 AR09E2F6A 6 AMPERE WIRE FILTER 1 37 0105 1 PLATE FRAME 1 37 1040 N THERMOREGULATOR 1 37 SONDAPF PROBE FOR THERMOREGULATOR 1 37 RELE1040 25...

Page 18: ...n 411717683 Bio Optica Milano S p A via San Faustino 58 I 20134 Milano Tel 39 02 21 27 13 1 Fax Acquisti Export 39 02 21 54 155 Fax Assistenza Contabilit 39 02 26 41 74 48 Fax Vendite 39 02 21 53 000...

Page 19: ...vitro diagnostic medical device das Medizinprodukt f r die In vitro_Diagnostik le dispositif m dical de diagnostic in vitro PIASTRA FREDDA COOLING PLATE PF100 della classe of class der Klasse de la c...