BIO-LAB CANADA 28069 Installation And Operation Manual Download Page 8

Key Features

 

 

The 

Control Panel Display

 provides a 

 

P o o l   P i l o t ™

 

series of control buttons for 

OUTPUT

 level,

 

OUTPUT

 

S o f t   T o u c h

 

BOOST

 mode and 

SETUP

 functions, with 

 

  FLOW-OK 

 SERVICE 

CELL POWER

 

diagnostic indicator

 

lights for 

FLOW-OK

,      1

00%

 

 

                                                1 

SALT and

 

SERVICE.

  Two additional 

 

 

  

                                                                             2

 

indicator lights show

 

the selected setup

   

  

 SALT                                               3

 

CELL POWER

 and 

REVERSING 

cycle.    

50% OK 

REVERSING 

  

 

 

 

BOOST

 

                              SHORT 

The 

Pool Pilot™

 

Soft Touch

 SANITIZER 

 

 

LOW                                    NORMAL   

 

OUTPUT

 level is adjustable from 0% (OFF) 

 

 

                                   

LONG

   

to 100 %(MAX).  Press the 

Up/Down Arrows

 0% 

 

ADD

                                   

to set the desired output level.  Little adjustment

 

 

  Concealed Set Up Button 

 

 

is needed once the initial setting is established.   
The selected output level will remain steady when the system is at rest and will begin pulsing when the system is producing the 
SANITIZING agent.  

Note: The 

Pool Pilot

™ Soft Touch does not test for SANITIZER levels nor automatically adjust to 

maintain a desired SANITIZER level.  This is done by periodically testing the water and adjusting the output levels up or 
down, as needed.   

The Pool Pilot 

Soft Touch

 is designed with an 

AUTOMATIC TEMPERATURE COMPENSATION feature

, which automatically 

adjusts the output level setting based upon changes in seasonal water temperatures only.  This unique feature conveniently 
compensates for warm (more SANITIZER needed) or cold (less SANITIZER needed) water conditions.  
The 

SETUP Mode

 allows the user to program the 

CELL POWER 

and 

REVERSING 

cycle.  To enter Setup Mode, press and hold 

the concealed Setup button (small bubble adjacent to the Salt OK light) until the 

CELL POWER

 light begins flashing.  The 

Pool 

Pilot

™ 

Soft Touch

 is set on  

 

2

 

 from the factory.  Use the Up/Down Arrows to change the Cell Power setting if needed.  Adjust the 

OUTPUT level at the new setting to maintain proper sanitizer levels.  

WARNING:

 Operating on 

 

1

 

 reduces cell power but extends cell life;

 “ 3 “

 increases cell power but reduces cell life.   

Pressing the Setup Button once more will go to the 

REVERSING

 cycle.  The 

Pool Pilot

™ 

Soft Touch

 is set on “

NORMAL

” from 

the factory for ideal cell life.  Use the Up/Down Arrows to select the Reversing cycle.  For conditions such as extremely high calcium 
levels or conditions that can cause the cell to scale quicker than the self-cleaning cycle can control, change the setting to “

SHORT

”.  

For optimum water chemistry balance according to the Saturation Index, see page 9, you can change the REVERSING cycle to 

LONG

”.  Pressing the setup button once more will leave the Setup Mode and save the programmed Cell Power and Reversing 

settings.  Test your water chemistry parameters monthly and compare to the Saturation Index.     

WARNING

: Changing the Reversing cycle to SHORT will also reduce cell life.  However, operating the cell under scaled conditions 

on “Normal” or “Long” is more detrimental to the life of the cell and changing the Reverse cycle is suggested. 

 

The 

BOOST

 

Button

 activates the Boost light when it is pressed once.  This light indicates that the system is in Boost Mode and will 

produce the SANITIZING agent for 24 hours.  The SANITIZING agent can be produced for 72-hours by pressing and holding the 
BOOST button for 5-seconds from the Boost-Off position.  This is called the 

Super-Boost Mode

.  A flashing Boost light indicates 

that the system has successfully entered this mode.  In either mode, the SANITIZING agent is produced continuously, throughout the 
normal On/Off cycles of the pump and throughout all power line disturbances at an output SANITIZING level of 100% regardless of 
the normal SANITIZING output level setting.  The system will discontinue operation of the Boost mode or Super Boost mode if the 
boost button is pressed once more and return to the normal SANITIZING output level setting.  The pool/spa pump must be turned on 
during the whole boost cycle.  Do not let the pump run on a timer during that period. 

 

The 

SALT

 light indicates the salt level in the water.  The salt level should be maintained between 2.8 – 3.2 g/l (2800 – 3200 ppm).  

The SALT-

OK

 light will be on if this salt level is achieved.  If the salt level drops below 2.5 g/l (2500 ppm), the SALT-

LOW

 light 

will turn on and the system will continue to produce the SANITIZING agent.  If the salt level drops below a safe value, the SALT-

ADD

 light will turn on and the system will no longer continue to produce the SANITIZING agent.   

(

NOTE

 Maintaining high salt levels above recommended range can contribute to corrosion of pool/spa equipment.  Salt levels 

exceeding the recommended concentration can be reduced by diluting the pool/spa with fresh water.)  See Appendix (page 14) to 
determine your salt level. 

 

The 

FLOW-OK

 light turns on when there is sufficient flow.  Any problems with insufficient water flow is indicated by a Flow-OK 

light that is not on and a Flashing Service Light (single flash pattern).  

 

The 

SERVICE

 light flashes when service is needed.  A Single flash pattern of the service light indicates insufficient water Flow.  A 

Double flash pattern of the service light indicates high cell volts and low amps, which is caused by a scaled or failing cell or a 
loose/defective cell cord.  A Triple flash pattern of the service light indicates high cell volts and low amps, which is caused by a failed 
power supply.  A Quadruple flash pattern of the service light indicates a failed tri-sensor or cord.

 
 

7

Summary of Contents for 28069

Page 1: ... Controls Bacteria And Algae In Swimming Pool Waters For Indoor or Outdoor use RETAIN MANUAL FOR FUTURE REFERENCE NSF50 C IMPORTANT READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING Notice to User This control product is to be used only in accordance with the directions on this label It is an offense under the Pest Control Products Act to use a control product under unsafe conditions Bio ...

Page 2: ..._________________ Control Unit Control Unit Model Number ST60______________ Serial Number ____________________________ Cell Model Number RC 13 Serial Number ____________________________ Customer Assistance HOTLINE 1 800 268 6572 or 905 686 8836 FAX 905 619 8696 Manufactured for Bio Lab Canada Inc 1005 Copperstone Drive Pickering ON L1W 4A5 Pool Pilot Soft Touch by BIO LAB CANADA INC 1 ...

Page 3: ...try in accordance with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times Children should not use spas hot tubs or pools without permanent adult supervision Equipment Related 115 230VAC 50 60 Hz Models fixed wiring 1 A wire connector is provided on your Pool Pilot Soft Touch to connect a minim...

Page 4: ... Sensor Connections ORP Connections 2c Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Control Panel 7 3b Pool Water Preparation 8 Salt Requirement Chart Start Up Procedures 8 3c Monitoring and Maintenance 9 Water Chemistry Parameters Saturation Index Section 4 SERVICE and MAINTENANCE 4a Servicing 10 Control Box Tri Sensor 4b Servicing ...

Page 5: ... Remove the cover by following the steps pool or spa instructions to remove and inspect on page 10 to access the mounting See page 8 for salt requirements the tri sensor assembly holes to tighten the screws RATINGS Input Power 115 VAC 3 0 AC amps MaximumOutput Equivalent to 0 77 kg 1 68 lbs of free available chlorine day 230 VAC 1 5 AC amps RC 13 CELL Cell Power Level 3 8 amps DC 50 60 Hz Cell Lif...

Page 6: ...Gr Yel Br Bl 2 pin ORP Cell Cord AC Line In Plug Plug 1 6 5 4 3 2 Connector Connectors Pool Pilot AC Line IN CONTROL BOX BASE PLATE AC LINE IN Wiring diagram also located on inside of cover For 230 VAC Brown Br Line 1 Blue Bl Line 2 Green w Yellow Tracer Gr Yel Earth Ground For 115 VAC Brown Br Line Blue Bl Neutral Green w Yellow tracer Gr Yel Earth Ground The AC Line IN wiring is pre set for conn...

Page 7: ...ify that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or equipment damage Using either a GOLF BALL or small plastic wrap saran wrap food wrap or zip lock bag block off flow to the upper portion of the manifold by placing the golf ball in the strainer screen uni...

Page 8: ...r water chemistry parameters monthly and compare to the Saturation Index WARNING Changing the Reversing cycle to SHORT will also reduce cell life However operating the cell under scaled conditions on Normal or Long is more detrimental to the life of the cell and changing the Reverse cycle is suggested The BOOST Button activates the Boost light when it is pressed once This light indicates that the ...

Page 9: ...ies TEST YOUR WATER FOR SALT LEVEL FIRST with the provided salt test strips and then use the chart below to determine the amount of salt to add SALT REQUIREMENT CHART KILOS LBS OF SALT NEEDED FOR 3000 PPM RESIDUAL Pool Volume in Liters US Gallons SALT Level Before Addition 3 780 1 000 9 430 2 500 18 900 5 000 28 300 7 000 37 780 10 000 56 700 15 000 75 600 20 000 113 600 30 000 0 ppm 11 3 25 28 63...

Page 10: ...odium hypochlorite and does not affect the calcium hardness or total alkalinity levels Maintain and balance only as needed CYANURIC ACID STABILIZER CONDITIONER This chemical goes by either trade name and allows the chlorine residual to last longer by protecting it from the UV degradation of the sun With low or no Cyanuric acid it is possible for the chlorine to be used up as quickly as it enters t...

Page 11: ...trol Circuit lift off metal cover electrical connections remove these board removes with cover fuses and pump aux relay Fuse Location and Ratings F1 Main AC Power Fuse 6 Amps 250 VAC F2 Control Panel Circuit Board Fuse 3 Amps 250 VAC F3 Cell Fuse 20 Amps 250 VAC TRI SENSOR ASSEMBLY The Tri sensor assembly tests for Flow Salt and Water temperatures A minimum flow rate of 94 5 L min 25 US Gallons mi...

Page 12: ...h a mixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution in a container high enough to cover the Cell blades You may also use a non fuming pre mixed cell cleaner per label directions Remove the Cell cord and immerse the Cell so that the blades are completely covered in the solution for up to 15 minutes An effervescences action indicates the calcium is being neutralized and ...

Page 13: ...l Unions and Cord ordered separately 12ft 3 6m Cell Cord 952 1 Union O Ring 19013 Cell RC 13 Nut Half only 2 pcs for 2 in 50 mm S x S Union Thread Half Only for 2 in 50 mm S x S Union Tri Sensor Assembly Cord Ordered Separately Directional Flow Indicator View of locking Quick connect heads 12ft 3 6m Tri Sensor Cord 956 DIG Tri Sensor O Ring 19028 Direction of Water Flow Temperature Sensor Post Sal...

Page 14: ...B See Section 2 above C Cell Power selection not matched to the Cell installed C Follow the SETUP procedures to match the cell see page 7 5 White Flakes in the Water A This occurs when excessive calcium hardness is A Visually inspect Cell for scale build up and clean the cell as present Usually due to water chemistry imbalance described on page 11 Adjust your water chemistry 6 No Power to the Cont...

Page 15: ...se of salt the top light is not used the next to the top flashes the 1000 s digit and the third light flashes the 100 s digit in ppm Example 2 flashes pause 8 flashes pauseRead 2 800 PPM 2 The second value is the water temperature in degrees Fahrenheit When this is displayed the second light from the bottom is on The top light flashes the 100 s digit the next the 10 s digit and the next the units ...

Page 16: ...READ THE LABEL AND THE INSTALLATION AND OPERATION MANUAL BEFORE USING Imported to Canada for BIO LAB CANADA INC 1005 Copperstone Drive Pickering ON L1W 4A5 REGISTRATION NO 28069 PEST CONTROL PRODUCTS ACT MINERAL SPRINGS SOFT TOUCH MODEL ST60 Chlorine Generating Device One ST60 unit can treat a maximum of 190 000 Liters of swimming pool water Notice to User This control product is to be used only i...

Page 17: ...REGISTRATION NUMBER 28069 PEST CONTROL PRODUCTS ACT This cell must only be used on these models of chlorine generating device Read the Label and the Installation and Operation Manual of the chlorine generating device MINERAL SPRINGSModel DIGITAL 60 or MINERAL SPRINGSModel Soft Touch ST60 before using BIO LAB CANADA INC 1005 Copperstone Drive Pickering ON L1W 4A5 MINERAL SPRINGS Cell Label for DIG ...

Page 18: ...formation This service and this information do not replace the official hard copy label The PMRA does not provide any guarantee or assurance that the information obtained through this service is accurate current or correct and is therefore not liable for any loss resulting directly or indirectly from reliance upon this service ...