BIO-LAB CANADA 28069 Installation And Operation Manual Download Page 10

Section 3c

 – OPERATION 

Monitoring and Maintenance 

 

Water Chemistry Parameters

 

VERY IMPORTANT NOTE!

  

Your 

Pool Pilot

™ 

Soft Touch

 is designed to provide SANITIZER on a daily basis.  

We recommend the following water chemistry ranges and periodic checks to monitor your systems efficiency.  Always follow all local and state 
requirements.  Check the expiry date of the test kit as test results may be inaccurate if used after that date.

 

 

  

Daily Checks: 

_____                ________________

Monthly Checks:____________________________ 

Free Chlorine:

 

1.0 – 3.0 PPM (pool) 

          

Calcium Hardness:

 200 – 300 PPM (pool)  150-200 (spa)    

Salt Residual::            

2800 – 3200 PPM 

Or Bromine:

 

1.0 – 3.0 PPM (pool) 

           

Total Alkalinity:

 

100 – 120 PPM (pool  & spa)                

Saturation Index:      

± 0.3 pH of saturation 

Free Chlorine:

 

3.0 – 5.0 PPM (spa) 

           

Cyanuric Acid:

 

30 –100 PPM     (pool  & spa)           

Visual Cell Inspection

 for wear, scale or debris 

  

Free Bromine:           3

.0 – 5.0 PPM (spa)

 

 

   pH:

 

                  7.2 – 7.8

 

 
CHLORINE/BROMINE REQUIREMENTS:

 During Peak SANITIZER Demand (rainy season or heavy bather usage) it may be 

necessary to increase your SANITIZER level by increasing your Output Level setting and/or pump run time.  Conversely, during Low 
SANITIZER Demand, you can decrease your Output Level to a lower setting.  For extremely Heavy SANITIZER Demand or to boost 
your SANITIZER levels quickly, you can 

Boost

 the system or supplement with a Potassium Monopersulfate based shock.  If the 

water is clear but is difficult getting a bromine residual using DPD or test strips, we recommend using an OTO test kit. 

NOTE:  During cold-water conditions, below 60ºF, SANITIZER demand is reduced significantly.  

For colder climate regions 

with sustained low or freezing temperatures, contact your local pool professional for proper pool winterizing instructions.   

WARNING:

 Excessive chlorine levels can cause corrosion damage to stainless steel rails, ladders, heater heat exchangers, light 

faceplates and other metallic equipment.  Avoid over saturation of chlorine levels.  The output setting must be sufficiently high to 
maintain the recommended chlorine residual in the swimming pool/spa water.  Provincial and/or municipal regulation must be 
followed. 

pH:

 When pH levels fall below the recommended range, SANITIZER is used up quickly and can be damaging to equipment.  For pH 

levels higher than the recommended range, SANITIZER becomes less effective and works harder to keep your pool sanitized.  
Improper pH also contributes to the strong smell, red eyes, dry itchy skin and brittle hair conditions associated with “too much 
Chlorine”.  

CALCIUM HARDNESS AND TOTAL ALKALINITY:

 Your 

Pool Pilot

™ 

Soft Touch

 provides 100% pure sodium hypochlorite 

and does not affect the calcium hardness or total alkalinity levels.   Maintain and balance only as needed. 

CYANURIC ACID (STABILIZER/CONDITIONER):

 This chemical goes by either trade name and allows the chlorine residual to 

last longer by protecting it from the UV degradation of the sun.  With low or no Cyanuric acid it is possible for the chlorine to be used 
up as quickly as it enters the pool.  Check and maintain your cyanuric acid levels at the same time as your salt level, as these tend to 
deplete at the same rate.  Regulations may exist regarding the use of cyanuric acid; please consult your local authority.  

NOTE: For 

Bromine or indoor pools, it is not necessary to add stabilizer.

  

SALT RESIDUAL:

 Your 

Pool Pilot

™ 

Soft Touch

 works most efficiently with salt levels between 2.8 – 3.2 g/l (2800- 3200 ppm).  If 

it falls below 2.8 g/l (2800 ppm), determine the salt level and adjust according to the SALT REQUIREMENT.  Low salt will cause 
premature deterioration of the Cell blades.  Maintaining high salt levels above recommended range can contribute to corrosion of 
pool/spa equipment.  Salt levels exceeding the recommended concentration can be reduced by diluting the pool/spa with fresh water. 

BROMINE RESIDUAL: 

Along with the normal Salt level, add 0.45 kg (1 lb) Sodium Bromide (NaBr) per 7500 L (2000 gallons) of 

water  Your 

Pool Pilot

™ 

Soft Touch

 will now generate Bromine to purify your pool.  Maintain your bromine level by checking your 

salt level.  Once your salt falls below the recommended range, we suggest you add 0.45 kg ( 1 lb) sodium bromide with every 22.5 kg 
(50 lbs) of salt added.  Always use a registered or scheduled source of sodium bromine..

 

SATURATION INDEX (Si):

 a formula used to ensure that your total water chemistry does not fall into a scale forming or corrosive 

condition.  Either condition can cause premature damage to the Cell, equipment and cementitious finish.  Have your water 
professionally tested periodically according to the Saturation Index or use this chart to determine your water balance. 

 

Si = pH + TF + CF + AF – Constant 

   Temperature 

TF 

Calcium Hardness 

CF 

Total Alkalinity 

AF 

TDS 

    Constant   

   15.6C    60F 

0.4

 150 

1.8

 75 

1.9 

     

0 – 1000

 12.1

   

    18.9C    66F 

0.5

 200 

1.9

 100 

2.0 

1001 - 2000 

12.2

   

    24.4C    76F          

0.6

 250 

2.0

 125 

2.1 

2001 - 3000 

12.3

   

    28.9C    84F 

0.7

 300 

2.1

 150 

2.2

 

3001 - 4000 

12.4

   

    34.4C    94F 

0.8

 400 

2.2

 200 

2.3

 

4001 - 5000 

12.5

   

    39.4C     103F 

0.9

 600 

2.4

 250 

2.4 

5001 - 6000 

12.6

   

 

Test your water for pH, Calcium Hardness, Total Alkalinity and TDS levels.  Use the equivalent Factor in the Si equation. 

Si = +0.3; balanced

  

Si above + 0.3; scaling, staining or cloudy water conditions. 

Si below -0.3; corrosive to metals, etches/deteriorates plaster finishes or skin irritating conditions. 

DO NOT add pool/spa chemicals directly to the skimmer.  This may damage the cell. 

 

 
 

9

Summary of Contents for 28069

Page 1: ... Controls Bacteria And Algae In Swimming Pool Waters For Indoor or Outdoor use RETAIN MANUAL FOR FUTURE REFERENCE NSF50 C IMPORTANT READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING Notice to User This control product is to be used only in accordance with the directions on this label It is an offense under the Pest Control Products Act to use a control product under unsafe conditions Bio ...

Page 2: ..._________________ Control Unit Control Unit Model Number ST60______________ Serial Number ____________________________ Cell Model Number RC 13 Serial Number ____________________________ Customer Assistance HOTLINE 1 800 268 6572 or 905 686 8836 FAX 905 619 8696 Manufactured for Bio Lab Canada Inc 1005 Copperstone Drive Pickering ON L1W 4A5 Pool Pilot Soft Touch by BIO LAB CANADA INC 1 ...

Page 3: ...try in accordance with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times Children should not use spas hot tubs or pools without permanent adult supervision Equipment Related 115 230VAC 50 60 Hz Models fixed wiring 1 A wire connector is provided on your Pool Pilot Soft Touch to connect a minim...

Page 4: ... Sensor Connections ORP Connections 2c Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Control Panel 7 3b Pool Water Preparation 8 Salt Requirement Chart Start Up Procedures 8 3c Monitoring and Maintenance 9 Water Chemistry Parameters Saturation Index Section 4 SERVICE and MAINTENANCE 4a Servicing 10 Control Box Tri Sensor 4b Servicing ...

Page 5: ... Remove the cover by following the steps pool or spa instructions to remove and inspect on page 10 to access the mounting See page 8 for salt requirements the tri sensor assembly holes to tighten the screws RATINGS Input Power 115 VAC 3 0 AC amps MaximumOutput Equivalent to 0 77 kg 1 68 lbs of free available chlorine day 230 VAC 1 5 AC amps RC 13 CELL Cell Power Level 3 8 amps DC 50 60 Hz Cell Lif...

Page 6: ...Gr Yel Br Bl 2 pin ORP Cell Cord AC Line In Plug Plug 1 6 5 4 3 2 Connector Connectors Pool Pilot AC Line IN CONTROL BOX BASE PLATE AC LINE IN Wiring diagram also located on inside of cover For 230 VAC Brown Br Line 1 Blue Bl Line 2 Green w Yellow Tracer Gr Yel Earth Ground For 115 VAC Brown Br Line Blue Bl Neutral Green w Yellow tracer Gr Yel Earth Ground The AC Line IN wiring is pre set for conn...

Page 7: ...ify that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or equipment damage Using either a GOLF BALL or small plastic wrap saran wrap food wrap or zip lock bag block off flow to the upper portion of the manifold by placing the golf ball in the strainer screen uni...

Page 8: ...r water chemistry parameters monthly and compare to the Saturation Index WARNING Changing the Reversing cycle to SHORT will also reduce cell life However operating the cell under scaled conditions on Normal or Long is more detrimental to the life of the cell and changing the Reverse cycle is suggested The BOOST Button activates the Boost light when it is pressed once This light indicates that the ...

Page 9: ...ies TEST YOUR WATER FOR SALT LEVEL FIRST with the provided salt test strips and then use the chart below to determine the amount of salt to add SALT REQUIREMENT CHART KILOS LBS OF SALT NEEDED FOR 3000 PPM RESIDUAL Pool Volume in Liters US Gallons SALT Level Before Addition 3 780 1 000 9 430 2 500 18 900 5 000 28 300 7 000 37 780 10 000 56 700 15 000 75 600 20 000 113 600 30 000 0 ppm 11 3 25 28 63...

Page 10: ...odium hypochlorite and does not affect the calcium hardness or total alkalinity levels Maintain and balance only as needed CYANURIC ACID STABILIZER CONDITIONER This chemical goes by either trade name and allows the chlorine residual to last longer by protecting it from the UV degradation of the sun With low or no Cyanuric acid it is possible for the chlorine to be used up as quickly as it enters t...

Page 11: ...trol Circuit lift off metal cover electrical connections remove these board removes with cover fuses and pump aux relay Fuse Location and Ratings F1 Main AC Power Fuse 6 Amps 250 VAC F2 Control Panel Circuit Board Fuse 3 Amps 250 VAC F3 Cell Fuse 20 Amps 250 VAC TRI SENSOR ASSEMBLY The Tri sensor assembly tests for Flow Salt and Water temperatures A minimum flow rate of 94 5 L min 25 US Gallons mi...

Page 12: ...h a mixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution in a container high enough to cover the Cell blades You may also use a non fuming pre mixed cell cleaner per label directions Remove the Cell cord and immerse the Cell so that the blades are completely covered in the solution for up to 15 minutes An effervescences action indicates the calcium is being neutralized and ...

Page 13: ...l Unions and Cord ordered separately 12ft 3 6m Cell Cord 952 1 Union O Ring 19013 Cell RC 13 Nut Half only 2 pcs for 2 in 50 mm S x S Union Thread Half Only for 2 in 50 mm S x S Union Tri Sensor Assembly Cord Ordered Separately Directional Flow Indicator View of locking Quick connect heads 12ft 3 6m Tri Sensor Cord 956 DIG Tri Sensor O Ring 19028 Direction of Water Flow Temperature Sensor Post Sal...

Page 14: ...B See Section 2 above C Cell Power selection not matched to the Cell installed C Follow the SETUP procedures to match the cell see page 7 5 White Flakes in the Water A This occurs when excessive calcium hardness is A Visually inspect Cell for scale build up and clean the cell as present Usually due to water chemistry imbalance described on page 11 Adjust your water chemistry 6 No Power to the Cont...

Page 15: ...se of salt the top light is not used the next to the top flashes the 1000 s digit and the third light flashes the 100 s digit in ppm Example 2 flashes pause 8 flashes pauseRead 2 800 PPM 2 The second value is the water temperature in degrees Fahrenheit When this is displayed the second light from the bottom is on The top light flashes the 100 s digit the next the 10 s digit and the next the units ...

Page 16: ...READ THE LABEL AND THE INSTALLATION AND OPERATION MANUAL BEFORE USING Imported to Canada for BIO LAB CANADA INC 1005 Copperstone Drive Pickering ON L1W 4A5 REGISTRATION NO 28069 PEST CONTROL PRODUCTS ACT MINERAL SPRINGS SOFT TOUCH MODEL ST60 Chlorine Generating Device One ST60 unit can treat a maximum of 190 000 Liters of swimming pool water Notice to User This control product is to be used only i...

Page 17: ...REGISTRATION NUMBER 28069 PEST CONTROL PRODUCTS ACT This cell must only be used on these models of chlorine generating device Read the Label and the Installation and Operation Manual of the chlorine generating device MINERAL SPRINGSModel DIGITAL 60 or MINERAL SPRINGSModel Soft Touch ST60 before using BIO LAB CANADA INC 1005 Copperstone Drive Pickering ON L1W 4A5 MINERAL SPRINGS Cell Label for DIG ...

Page 18: ...formation This service and this information do not replace the official hard copy label The PMRA does not provide any guarantee or assurance that the information obtained through this service is accurate current or correct and is therefore not liable for any loss resulting directly or indirectly from reliance upon this service ...

Reviews: