***In  case  of  clogging  in  the  Microblaster  internal  pipeline,  a  simple  "Retro-
blasting"  procedure  might  solve  the  problem.  For  this  purpose,  see  the 
information described in item 8. Maintenance and cleaning of this user manual.

13. SYMBOLS

14. TERM OF WARRANTY AND AUTHORIZED
TECHNICAL ASSISTANCE

Check Instructions

for Use 

Authorized Representative in

the European Community 

Serial Number

Model Code

Date of manufacture

Manufacturer's data

Attention!

Keep in dry place

This side up

Fragile

10

Maximum piling

BIO-ART Equipamentos Odontológicos Ltda., grants a six-month warranty for this 
product, starting from the date of its acquisition. This warranty covers all and any 
manufacturing  defect,  being  provided  through  repair  of  the  equipment,  and 
subjected to the following requirements:
• That the product has been used correctly in accordance with the instructions 
described in the user manual;
• The claim is accompanied by the purchase invoice and registered within the 
warranty period, followed by a report with description of the defect and the product 
serial number;
• The product is handled, transported and stored with care;
• The transport cost (round trip) is paid by the customer;

Warranty limitations:

• Natural wear of parts;
• Misuse, falls or accidents;
• Inadequate transport;
• Repair by non-authorized personnel;
• Use in disagreement with the device features and purposes;
• Wear due to exposure to adverse conditions (humidity, cold and intense heat);
• Damage due to lack of cleaning or maintenance with inappropriate products;

Summary of Contents for Microblaster

Page 1: ...MicroBlaster i n t e l l i g e n t s o l u t i o n s USER MANUAL...

Page 2: ...lation instructions 7 Use instructions 8 Maintenance and cleaning 9 Safety precautions 10 Warnings 11 Special storage conditions 12 Problems and solutions 13 Symbols 14 Term of warranty and technical...

Page 3: ...Microblaster Standard and Lab Models One xed nozzle mounted at a 138 angle Microblaster Plus Model Two removable and autoclavable nozzles mounted at 90 and 138 angles Attention Before operating the eq...

Page 4: ...138 Yes Yes No No No Yes No No Yes Yes Yes Yes Yes No Yes No Yes No Removable nozzles with ejecting needles at 90 and 138 Autoclavable nozzles Use of aluminum oxide with granulation up to 100 microns...

Page 5: ...t and the user s safety and for better performance during the blasting works make sure the compressed air pressure is kept stable at 60 to 80 lbf inch2 4 5 5 Kgf cm Bio Art supplies the connections 07...

Page 6: ...d intraoral works on anterior teeth According to the kind of work to be carried out x one of the nozzles on the Microblaster body by means of the xing nut 12 _______During the nozzles removal or xatio...

Page 7: ...constant movements throughout the whole surface to be blasted Some recommendations for the aluminum oxide granulation indicated for some application examples are presented below It is upon the profes...

Page 8: ...croblaster cleaning and disinfection use only a cloth dampened with water or alcohol 70 _______Bio Art Microblaster shall never be sprayed with liquids be submerged _______or sterilized in an oven or...

Page 9: ...goggles gloves and breathing mask when operating the equipment In addition to these EPI s and for cases when the work offers such conditions we recommend the use of the Bio Art Bio Chamber suction ch...

Page 10: ...s user manual and monitor the correct pressure 60 to 80 lbf inch 4 5 5 Kgf cm Fill the tank 06 in with aluminum oxide at maximum of 3 4 of its capacity The compressed air network shall be dry Check th...

Page 11: ...s all and any manufacturing defect being provided through repair of the equipment and subjected to the following requirements That the product has been used correctly in accordance with the instructio...

Page 12: ...637 034 447 113 _______www bioart com br 15 AUTHORIZED TECHNICAL ASSISTANCE 16 EUROPEAN AUTHORIZED REPRESENTATIVE For your safety technical assistance on this product shall only be provided by authori...

Page 13: ......

Page 14: ...Rev CMAN0274 f Fev 2016 i n t e l l i g e n t s o l u t i o n s Rua Teot nio Vilela 120 Jd Tangar CEP 13568 000 S o Carlos SP Brasil Tel 55 16 3371 6502 Fax 55 16 3372 5953 www bioart com br...

Reviews: