M-Drive
9 Maintenance and cleaning
EN - 21
9.1 Maintenance intervals
Observe the instructions of the guideline EN 60974-4 Inspection and test during the operation of arc
welding equipment as well as the laws and guidelines valid in the respective country.
Check the following:
NOTICE
• The maintenance intervals given are standard values and refer to single-shift operation.
1
Wire inlet
2
Grub screw
3
Connection nipple
4
Masterliner wire outlet
5
Quick coupling
6
Nut
7
Wire guide tube
8
Screw
Fig. 15
Maintenance and cleaning
1
2
3
4
5
6
7
8
Weekly
Monthly
Every six months
Visual inspection of the wire inlet and wire outlet liner. In case of wear,
replace as follows:
, replace the wire inlet
and secure with the
again.
• Check that the
connections (cable
assembly, control lead,
ground) are secure.
Tighten if necessary.
• Remove the side panel.
Air blast the housing
interior using dry
compressed air to
remove any dirt.
Visual inspection of the Masterliner wire outlet
. In case of wear,
replace as follows:
• Release the wire outlet
from the quick coupling
. Undo the
nut
from the wire outlet
. Replace the connection nipple
the plastic liner then secure again with the nut
. Insert the wire
outlet
into the quick coupling
Tab. 11
M-Drive maintenance and cleaning