The fan unit consists of the fan insertion and the fan cassette. The fan insertion,
located in the fan cassette, can easily be installed or replaced.
The fan insertion is hot swappable, meaning that you will be able to safely insert
or remove the fan insertion while power is on. Still, during installation the cooling
of the inserted components is not warranted and components may be quickly
overheated. Therefore, a speedy installation is recommended.
Since during installation the cooling of the inserted components is
not warranted, BinTec Access Networks GmbH recommend not
to operate the device longer than five minutes without cooling.
Note before installation:
➤
Read the installation instructions.
➤
Prepare the installation.
The fan insertion is a wear part. BinTec Access Networks GmbH
recommends to observe the necessary maintenance intervals
after 3 years of operation.
Caution!
Electrostatic charges can damage electronic components. Please
observe the following precautions to avoid damaging compo-
nents:
➤
Ground yourself before unpacking components and before
carrying out installation work on the equipment.
➤
Only grip boards and switches at the edges and do not touch
cables or components.