TorqueTrak Revolution Troubleshooting Guide  

 
 
WARNING: Supply voltage (up to 230VAC) is live inside the Master Control Unit (MCU) even when the Main Power 
switch is off! 

Use caution when accessing internal controls.   

 
When the TorqueTrak Revolution is first powered up, it cycles through the startup sequence, lasting 10-15 seconds.  
During startup mode, all of the Indicator lights flash in unison. If all system checks are positive, the Main System Status 
light on the outside of the control box remains on solid, and the system is ready for operation.   
 

Normal Operating Mode (no errors) 

Indicator  

Condition 

Main System Status (red light outside MCU) 

On solid 

Stator (green light inside MCU) 

On solid 

Rotor (green light inside MCU) 

On solid 

Data (green light inside MCU) 

On solid 

Range (red light inside MCU) 

Off 

 

If an error is present, the Main System Status light will flash and the system will display an error code briefly (another 10-
15 seconds) before the startup cycle repeats. Below are the most common error modes and potential corrective actions. 
 

Error Mode: Power supply voltage to system is incorrect 

Indicator 

Condition 

Suggested Corrective Action 

Main System Status 

Fast flash (4 Hz) 

1. Supply the correct voltage to the MCU (see manual 

for details) 

Stator 

Flashing (2 or 4 Hz) 

 

Error Mode: Weak inductive interface  

 

Indicator 

Condition 

Suggested Corrective Action 

Main System Status 

Fast flash (4 Hz) 

1. Make certain the Rotating Collar connectors are not 

damaged and are completely engaged  

2. Check alignment of the Rotating Collar within the 

Power Ring: the back surface of the Collar should 
align with the back edge of the Mounting Block  

3. Make certain the Power Coil is not shorted to the 

MCU enclosure by water or other conductive 
material 

4. Remove any surrounding metal other than the shaft 

within 1 inch (2.5 cm) of the Power Coil 

5. Verify that Rotating Coil voltage is about 120 mVAC 

(probe the two terminal dots on the outer surface of 
the Coil Boards attached to the Rotating Collar) 

6. Verify voltage is about 35 mVAC across the outer 

set of attachment screws to the Mounting Block 

7. Clean the mating surfaces of the Power Ring and 

tighten all the mounting screws 

Stator 

On solid 

Rotor 

Slow flash (2 Hz) 

Data 

Off or flickering 

 

 

 

Error Mode: Strain gage problem 

Indicator 

Condition 

Suggested Corrective Action 

Main System Status 

Fast flash (4 Hz) 

1. Verify the excitation voltage to the gage is 2.5 VDC 

(or light on Star Bridge should be on solid when 
connected in place of the gage) 

2. Check solder connections and wiring to the gage 
3. Balance the gage to reduce the offset or apply a 

new gage 

Stator 

On solid 

Rotor 

On solid 

Data 

On solid 

Range 

On solid 

 