4
Binks MODeL 44-6000 airLess 1M spraY gun Maintenance instructiOns
read and understand all warnings on page 2 before operating this equipment.
tO cLean nOzzLe tip
1. Turn safety knob (16) 90º to disengage trigger (22).
2. Shut off power supply to pump and release pressure
from gun. Remove gun from hose.
3. Remove tip guard assembly (1) and gasket (2).
4. Reassemble in reverse order.
tO repLace cartriDge asseMBLY (12)
1. Shut off power supply to pump and release pressure
from gun. Remove gun from hose.
2. Remove screw (17), safety knob (16) and guide (15).
3. Unscrew gland nut.
4. Pull cartridge assembly (12) out from back of gun.
5. Make sure inside of gun is clean.
6. Reinsert cartridge assembly (12) (of step 4) into
position through back of gun body assembly.
Tighten gland nut.
7. Reassemble items 13 through 17.
tO repLace pacKing (11)
1. Remove cartridge assembly following steps 1-4
under “To Replace Cartridge Assembly.”
2. Locate slot in packing gland (11), pry apart and
push off.
3. Replace with new packing gland, and reassemble.
tO aDjust pacKing gLanD (11)
1. Shut off power supply to pump and release pressure
from gun. Remove gun from hose.
2. Use a 7/16" open-end wrench to turn gland nut
clockwise to eliminate any leakage at gland.
3. If sluggish trigger operation is noted, turn gland nut
counterclockwise in 1/16 turn increments until drag
is eliminated.
4. If leakage cannot be stopped without excessive drag
on trigger, replace packing.
tO repLace seat (5)
1. Shut off air or power supply to pump and release
pressure from gun. Remove gun from hose.
2. Remove tip guard assembly (1) and gasket (2).
3. Remove nut diffuser and attached parts (3, 4, 5).
Seat should drop out.
4. Reassemble in reverse order.
54-2378
54-1835
54-1836
CAuTiOn
1. use care when handling nozzle tips to avoid dropping.
tips are made of tungsten carbide and are brittle.
2. never use metal probes to clean nozzle tips.
3. excessive fluid pressure will cause undue wear.
!
nOTe
use of diffuser/filter assembly will eliminate most tip clog-
ging problems.
DiFFuser asseMBLY accessOrY
Reduces fluid velocity to minimize tip wear and make tip removal safer.
Also to aid fluid filtration.
Order 54-2229 nylon gasket with set-up, described below.
54-2378 nut for use with 54-1835 (.005) or 54-1836 (.009) edge type filter.
FLat tip asseMBLies FOr airLess guns
Fan WiDtH
part
staMpeD
OriFice (12" FrOM
nuMBer nuMBer (incHes) surFace)
Fan WiDtH
part
staMpeD
OriFice (12" FrOM
nuMBer nuMBer (incHes) surFace)
9-1170 9-1170
.011
8-10
9-1180 9-1180
.011
10-12
9-1360 9-1360
.013
10-12
9-1380 9-1380
.013
12-14
9-1550 9-1550
.015
8-10
9-1560 9-1560
.015
10-12
9-1590 9-1590
.015
14-16
9-1840 9-1840
.018
10-12
9-1860 9-1860
.018
12-14
9-2140 9-2140
.021
10-12
9-2180 9-2180
.021
16-18
9-2340 9-2340
.023
10-12
9-2640 9-2640
.026
12-14
9-4340 9-4340
.043
12-14