BACK FLUSHING EXCESS 
MATERIAL

When spraying is complete, back flush 

remaining material in spray gun and hose as 

follows:
1.  Turn off air to material tank and bleed air 

out of the material tank.

2.  Loosen clamps on tank lid. Tip lid so 

material will run out of fluid tube into 

material tank.

3.  Loosen air cap on gun 2 to 3 turns and 

hold rag over cap. Pull trigger and force 

material from gun and hose back into 

tank.

TO CLEAN HOSE AND GUN 
PASSAGES:

1.  Fill Hose/Gun Cleaner with suitable 

cleaning solvent. Note: This model cannot 

be used with halogenated hydrocarbon 

solvents. Close lid on cleaner.

2.  Connect air hose to ¼ NPS(M) ball valve 

(4). Close ball valve. Regulate air pressure 

(must be remotely regulated) to a 

maximum of 110 PSI.

3.  Disconnect material hose from material 

supply tank and connect to 3/8 NPS(M) 

ball valve (5).

4.  Open both ball valves.
5.  Turn metering valve on top of the Hose/

Gun Cleaner to adjust the solvent-to-air 

ratio. Turn counterclockwise to increase 

solvent and clockwise to decrease solvent. 

Fully clockwise shuts off solvent 

completely. To begin, open 

counterclockwise 2 turns for sufficient 

solvent for cleaning.

6.  Trigger gun into a properly grounded 

container. Continue spraying until solvent 

is clear with no traces of paint.

7.  Turn metering valve full clockwise, 

shutting off solvent flow, while allowing air 

to continue to flow. Continue until all 

solvent is removed.

8.  Turn off air at source. Trigger gun to 

remove residual air pressure. Close both 

ball valves.

PREVENTIVE MAINTENANCE

Check Lid Gasket (11) and Needle Valve 

Gasket (2) for signs of wear or damage. 

Replace as needed.
Lift ring on safety valve (6) once a week to 

unseat it and make sure that it is working 

properly. Safety valve should be kept clean 

and free of dirt ad paint at all times.

ACCESSORIES

Air Supply Hose

71-20000 Air Hose – with static ground wire 

braid, 5/16” ID. Also need two re-useable 

72-1317 connectors.
  

Or

71-2100 Air Hose – with static ground wire 

braid, 3/8” ID. Also need two re-useable 

72-1325 connectors.
  

Or

Fluid Delivery Hose

71-282 Nylon lined fluid hose – 3/8” ID. Also 

need two re-useable 72-1328 connectors.

GROUNDING DIAGRAM

Purchase hardware locally

5/16–18 x 3/4 Long

Hex Head Bolt

(1 Required)

2X

5/16–18 Hex Head 

Nut (2 Required)

Sufficient Length

12 Gauge Wire

(Not Shown)

5/16 Lock Washer 

(1 Required)

Tank Skirt (Ref)

ITEM 

NO.

PART NO.

DESCRIPTION

QTY.

1

HD-409

NEEDLE VALVE ASSEMBLY

1

2

HD-39-K2

NEEDLE VALVE GASKET (KIT 0F 2)

1

3

HD-430

HD SUB ASSEMBLY

1

4

VA-542

BALL VALVE (1/4 NPS)

1

5

VA-540

BALL VALVE (3/8 NPS)

1

6

TIA-5110

SAFETY VALVE ASSEMBLY

1

7

SSG-8184-K2 O-RING (KIT OF 2)

1

8

• -----

PLUG (1/2-14 NPT)

1

9

• -----

PLUG (3/8-18 NPT)

1

10

QMG-400

TANK LID

1

11

QMS-80-1

TANK GASKET

1

12

PT-31

FLUID TUBE

1

13

PT-78-K10

TANK LINER (KIT OF 10)

1

14

KK-5013

CLAMP, PIN, & SCREW KIT

4

15

QMG-502-1

TANK & LUG ASSEMBLY

1

• Purchase locally

1

2

4

3

7

8

10

11

13

12

14

15

5

6

9

EN

77-2933-R1.0  (6/2017)

4 / 6

www.carlisleft.com

Summary of Contents for 183GZ-5200

Page 1: ...Regulator Assembly Typical Installation WETTED PARTS Galvanized steel aluminum nickel plated brass PTFE Santoprene Sarlink and polyethylene WARNING Static electricity produced when using this Hose Gu...

Page 2: ...pressure relief procedure in the equipment instruction manual NOISE HAZARD You may be injured by loud noise Hearing protection may be required when using this equipment STATIC CHARGE Fluid may develo...

Page 3: ...galvanized tank coating 1 Read the label or data sheet for the material Do not use materials containing these solvents with galvanized pressure tanks Stainless steel tank models may be used with halo...

Page 4: ...w Continue until all solvent is removed 8 Turn off air at source Trigger gun to remove residual air pressure Close both ball valves PREVENTIVE MAINTENANCE Check Lid Gasket 11 and Needle Valve Gasket 2...

Page 5: ...NOTES EN 77 2933 R1 0 6 2017 5 6 www carlisleft com...

Page 6: ...88 992 4657 Fax 1 888 246 5732 United Kingdom info carlisleft eu Tel 44 0 1202 571 111 Fax 44 0 1202 573 488 China mkt carlisleft com cn Tel 8621 3373 0108 Fax 8621 3373 0308 Mexico ventas carlisleft...

Page 7: ...ica principal Conjunto de regulador del filtro Instalaci n t pica PIEZAS HUMEDECIDAS Acero galvanizado aluminio lat n niquelado PTFE Santoprene Sarlink y polietileno ADVERTENCIA La electricidad est ti...

Page 8: ...uipment CARGA EST TICA Los fluidos pueden generar una carga est tica que debe ser disipada mediante la debida conexi n a tierra del equipo los objetos que van a ser atomizados y todos los dem s objeto...

Page 9: ...a la etiqueta y la hoja de informaci n del material No use materiales que contengan estos solventes con tanques a presi n galvanizados Se pueden usar modelos de tanques de acero inoxidable con solvent...

Page 10: ...mo tiempo que el aire fluya Contin e hasta que se haya eliminado todo el disolvente 8 Interrumpa el aire en la fuente Active la pistola para eliminar la presi n de aire residual Cierre ambas v lvulas...

Page 11: ...NOTAS ES 77 2933 R1 0 6 2017 ES 5 6 www carlisleft com...

Page 12: ...continuaci n EE UU Canad info carlisleft com Tel fono 1 888 992 4657 Fax 1 888 246 5732 Reino Unido info carlisleft eu Tel fono 44 0 1202 571 111 Fax 44 0 1202 573 488 China mkt carlisleft com cn Tel...

Reviews: