Binks 183GZ-5200 Service Manual Download Page 3

HAZARD

CAUSE

SAFEGUARDS

Fire

Solvents and coatings can be highly 

flammable or combustible, especially 

when sprayed.

1.  Adequate exhaust must be provided to keep the air free 

of accumulations of flammable vapors.

2.  Smoking must never be allowed in the spray area.

3.  Fire extinguishing equipment must be present in the 

spray area.

Fire – Pressure tank

Vapors from flammable liquids can 

catch fire or explode.

Keep tank at least 10 feet away from sources of ignition. 

Ignition sources include hot objects, mechanical sparks, and 

arcing (non -explosion proof) electrical equipment.

Explosion Hazard –

Pressure Tank – 

Static Electricity

Static electricity is created by the 

flow of fluid through the pressure 

tank and hose.  If all parts are not 

properly grounded, sparking may 

occur.  Sparks can ignite vapors from 

solvents and the fluid being sprayed.

1.  Ground the pressure tank by connecting one end of 12 

gauge (minimum) ground wire to the pressure tank and 

the other end to a true earth ground. Local codes may 

have additional grounding requirements.

2.  See illustration on page 4 for grounding and grounding 

hardware required.

Explosion Hazard –

Pressure Tank – 

Rupture

Making changes to a pressure tank 

will weaken it.

1.  Never drill into, weld, or modify the tank in any way.

2.  Do not adjust, remove, or tamper with the safety valve. 

If replacement is necessary, use the same type and rating 

of valve.

Explosion Hazard –

Galvanized Tanks – 

Material Compatibility

Halogenated hydrocarbon solvents 

– for example 1-1-1 Trichloroethane 

and methylene chloride – can 

chemically react with aluminum 

parts and components and cause an 

explosion hazard.  These solvents 

will also corrode the galvanized tank 

coating. 

1.  Read the label or data sheet for the material. Do not 

use materials containing these solvents with galvanized 

pressure tanks. Stainless steel tank models may be used 

with halogenated solvents.

2.  Refer to specifications chart to ensure that fluids are 

chemically compatible with the tank wetted parts. 

Before placing fluids or solvents in tank, always read 

accompanying manufacturer’s literature.

General Safety

Improper operation or maintenance 

may create a hazard.

Operators should be given adequate training in the safe 

use and maintenance of the equipment (in accordance with 

the requirements of NFPA-33, Chapter 15 in U.S.) Users 

must comply with all local and national codes governing 

ventilation, fire precautions, operation, maintenance, and 

housekeeping (in the U.S., these are OSHA sections 1910.94 

and 1910.107, and NFPA-33.

The following hazards may occur during the normal use of this equipment.  Please read the following chart.

!

 WARNING

High pressure can cause 

serious injury. 

Pressure is maintained in a 

pressure tank after the 

system has been shut 

down.

Always follow this 

procedure to relieve 

pressure from the tank.

1. Turn off the main air supply to the tank.

2. Close the air inlet valve located on the tank air manifold.

3.  Bleed off air in the tank by turning the air relief valve (5) thumb screw counterclockwise. Wait until all the 

air has escaped through the valve before removing the pressure tank cover or fill port cap.

4.  Leave the air relief valve open until you have reinstalled the tank cover or fill port cap.

PRESSURE RELIEF PROCEDURE

To reduce the risk of injury, follow the pressure relief procedure below 

•  Before checking or servicing any 

part of the spray system

•  Before attempting removal of fill 

port cap or tank cover

•  Whenever the tank is left 

unattended

EN

77-2933-R1.0  (6/2017)

3 / 6

www.carlisleft.com

Summary of Contents for 183GZ-5200

Page 1: ...Regulator Assembly Typical Installation WETTED PARTS Galvanized steel aluminum nickel plated brass PTFE Santoprene Sarlink and polyethylene WARNING Static electricity produced when using this Hose Gu...

Page 2: ...pressure relief procedure in the equipment instruction manual NOISE HAZARD You may be injured by loud noise Hearing protection may be required when using this equipment STATIC CHARGE Fluid may develo...

Page 3: ...galvanized tank coating 1 Read the label or data sheet for the material Do not use materials containing these solvents with galvanized pressure tanks Stainless steel tank models may be used with halo...

Page 4: ...w Continue until all solvent is removed 8 Turn off air at source Trigger gun to remove residual air pressure Close both ball valves PREVENTIVE MAINTENANCE Check Lid Gasket 11 and Needle Valve Gasket 2...

Page 5: ...NOTES EN 77 2933 R1 0 6 2017 5 6 www carlisleft com...

Page 6: ...88 992 4657 Fax 1 888 246 5732 United Kingdom info carlisleft eu Tel 44 0 1202 571 111 Fax 44 0 1202 573 488 China mkt carlisleft com cn Tel 8621 3373 0108 Fax 8621 3373 0308 Mexico ventas carlisleft...

Page 7: ...ica principal Conjunto de regulador del filtro Instalaci n t pica PIEZAS HUMEDECIDAS Acero galvanizado aluminio lat n niquelado PTFE Santoprene Sarlink y polietileno ADVERTENCIA La electricidad est ti...

Page 8: ...uipment CARGA EST TICA Los fluidos pueden generar una carga est tica que debe ser disipada mediante la debida conexi n a tierra del equipo los objetos que van a ser atomizados y todos los dem s objeto...

Page 9: ...a la etiqueta y la hoja de informaci n del material No use materiales que contengan estos solventes con tanques a presi n galvanizados Se pueden usar modelos de tanques de acero inoxidable con solvent...

Page 10: ...mo tiempo que el aire fluya Contin e hasta que se haya eliminado todo el disolvente 8 Interrumpa el aire en la fuente Active la pistola para eliminar la presi n de aire residual Cierre ambas v lvulas...

Page 11: ...NOTAS ES 77 2933 R1 0 6 2017 ES 5 6 www carlisleft com...

Page 12: ...continuaci n EE UU Canad info carlisleft com Tel fono 1 888 992 4657 Fax 1 888 246 5732 Reino Unido info carlisleft eu Tel fono 44 0 1202 571 111 Fax 44 0 1202 573 488 China mkt carlisleft com cn Tel...

Reviews: