background image

Instruction Manual 

 

 

 

 
 

Page 5 of 12 

77-3240-R1.0 

 

 

 

WARNING

 

 

READ THE MANUAL 

Before operating equipment, read 
and understand all safety, operation 
and maintenance information 
provided in the operation manual. 

 

PROP 65 WARNING 

WARNING: This product contains 
chemicals known to the State of 
California to cause cancer and birth 
defects or other reproductive harm. 

 

DE-ENERGIZE, DEPRESSURIZE, 
DISCONNECT AND LOCK OUT 
ALL POWER SOURCES DURING 
MAINTENANCE 

Failure to De-energize, disconnect 
and lock out all power supplies 
before performing equipment 
maintenance could cause serious 
injury or death. 

 

HIGH PRESSURE 
CONSIDERATION 

High pressure can cause serious 
injury. Relieve all pressure before 
servicing. Hose leaks, or ruptured 
components can inject fluid into 
your body and cause extremely 
serious injury. 

 

OPERATOR TRAINING 

All personnel must be trained before 
operating equipment. 

 

 
KNOW WHERE AND HOW TO 
SHUT OFF THE EQUIPMENT IN 
CASE OF AN EMERGENCY 

 

KEEP EQUIPMENT GUARDS IN 
PLACE 

Do not operate the equipment if the 
safety devices have been removed. 

 

NOISE HAZARD 

You may be injured by loud noise. 
Hearing protection may be required 
when using this equipment. 

 

PROJECTILE HAZARD 

You may be injured by venting 
liquids or gases that are released 
under pressure, or flying debris. 

 

AUTOMATIC EQUIPMENT 

Automatic equipment may start 
suddenly without warning. 

 

PINCH POINT HAZARD 

Moving parts can crush and cut. 
Pinch points are basically any areas 
where there are moving parts. 

 

 

WEAR SAFETY GLASSES 

Failure to wear safety glasses with 
side shields could result in serious 
eye injury or blindness 

 

MAGNETIC FIELD PRESENT 

You may be subjected to magnetic 
fields which may interfere with the 
operation of certain pacemakers. 

 

MAGNET HAZARD 

Take care when handling magnets. 
Avoid getting magnets in close 
proximity of each other. Injury or 
damage to magnets may result. 

Summary of Contents for 104099

Page 1: ...Instruction Manual For 104099 Auto Changeover Panel ...

Page 2: ...ctive 2006 42 EC and the ATEX Directive 94 9 EC by complying with the following statutory documents and harmonized standards Machinery Safety Standards EN ISO 12100 EN ISO 4413 EN ISO 4414 EN12621 Pressure Equipment Regulations 1999 SI 1999 2001 Providing all conditions of safe use stated within the product manuals have been complied with and that the final equipment into which this product is ins...

Page 3: ...0 Specification Part Number 104099 Max Air Pressure Inlet 7 Bar Compressed Air Inlet 1 4 BSP female Pilot Hose Connections 4mm Push In Air Quality ISO 8573 1 Class 5 5 4 Dirt 40 microns Water 7ºC 7bar Oil 25mg m Total Weight of Unit 2 7 Kg 6 lbs ...

Page 4: ...diately Do not exceed the maximum working pressure stated on the equipment or in the Technical Data for your equipment Do not exceed the maximum working pressure of the lowest rated component in your system Use fluids and solvents which are compatible with the equipment wetted parts Refer to the Technical Data section of all equipment manuals Read the fluid and solvent manufacturer s warnings Rout...

Page 5: ...nnel must be trained before operating equipment KNOW WHERE AND HOW TO SHUT OFF THE EQUIPMENT IN CASE OF AN EMERGENCY KEEP EQUIPMENT GUARDS IN PLACE Do not operate the equipment if the safety devices have been removed NOISE HAZARD You may be injured by loud noise Hearing protection may be required when using this equipment PROJECTILE HAZARD You may be injured by venting liquids or gases that are re...

Page 6: ...Instruction Manual Page 6 of 12 77 3240 R1 0 RAM 1 RESET DRUM EMPTY SIGNAL RAM 1 1 4 BSP AIR INLET PUMP START RAM 2 HORN EXHAUST DRUM EMPTY SIGNAL RAM 2 PUMP START RAM 1 HORN MUTE RAM 2 RESET ...

Page 7: ...Instruction Manual Page 7 of 12 77 3240 R1 0 MOUNTING DETAIL ...

Page 8: ... changeover panel 7 When the PUMP 1 ram hits the trip valve the pump will stop and PUMP 2 will automatically start The panel will also operate an alarm 8 Mute the alarm 9 Raise the PUMP 1 ram and remove the drum Details in Ram Unit manual 10 Place a new drum under the ram and lower into drum and leave ram set to down 11 Push the RESET button for PUMP 1 on the auto changeover panel 12 When the PUMP...

Page 9: ...rum under the ram 5 Push the RESET button for PUMP 1 6 When the PUMP 2 ram hits the trip valve the pump will stop and PUMP 1 will automatically start The panel will also operate an alarm 7 Mute the alarm 8 Raise the PUMP 2 ram and remove the drum 9 Place a new drum under the ram 10 Push the RESET button for PUMP 2 11 Continue from 1 12 You can stop and start the working pump at any time using the ...

Page 10: ...ruction Manual Page 10 of 12 77 3240 R1 0 RAM 2 DRUM EMPTY SIGNAL RAM 1 DRUM EMPTY SIGNAL RAM 2 AUTO PUMP START SIGNAL RAM 1 AUTO PUMP START SIGNAL RAM 1 CONTROL BOX RAM 2 CONTROL BOX AUTO CHANGEOVER PANEL ...

Page 11: ...Instruction Manual Page 11 of 12 77 3240 R1 0 ...

Page 12: ...Instruction Manual Page 12 of 12 77 3240 R1 0 ...