Binary B-520-EXT-230-RS-W Installation Manual Download Page 2

2

IMPORTANT SAFETY INSTRUCTIONS 

To reduce the risk of fire or electric shock, read and follow all instructions and warnings in this 
manual. Keep this manual for future reference.

1.  Do not expose this apparatus to rain or moisture. Do not expose this equipment to dripping 

or splashing, and ensure that no objects filled with liquids, such as vases, are placed on the 
equipment. Do not use this apparatus near water.

2.  Do not remove cover. No user serviceable parts inside. 

3.  Clean only with a dry cloth.

4.  Do not block any ventilation openings. Install according to manufacturer’s instructions.

5.  Do not install near any heat sources such as radiators, heat registers, stoves or other 

apparatus (including amplifiers) that produce heat.

6.  Do not override the safety purpose of the polarized or grounding plug. A polarized plug has 

two blades, one of which is wider than the other. A grounding plug has two matching blades 
and a third grounding prong. The wide blade or the third prong is provided for your safety. If 
the provided plug does not fit into your outlet, consult an electrician for replacement of the 
obsolete outlet.

7.  Protect the power cord from being walked on or pinched, particularly at the plug end and 

where the power cord is attached to the apparatus.

8.  Only use attachments and accessories specified by the manufacturer.

9.  Refer all servicing to qualified service personnel. Servicing is required when the apparatus 

has been damaged in any way, such as when the power supply cord or plug is damaged, 
liquid has been spilled on or objects have fallen into the apparatus, the apparatus has 
been exposed to rain or moisture, the apparatus does not operate normally, or it has been 
dropped.

10. To completely disconnect this equipment from power, disconnect the power supply cord 

from the power outlet.

The lightning flash with arrowhead symbol, within 
an equilateral triangle, is intended to alert the user 
to the presence of suninsulated dangerous voltage 
within the product’s enclosure that may be of 
sufficient magnitude to constitute a risk of electric 
shock to persons.
The exclamation point within an equilateral 
triangle is intended to alert the user to the 
presence of important operating and maintenance 
(servicing) instructions in the literature 
accompanying the appliance.

CAUTION

CAUTION: TO REDUCE THE RISK OF 

ELECTRICAL SHOCK.

DO NOT REMOVE COVER. NO USER 

SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED 
SERVICE PERSONNEL.

Summary of Contents for B-520-EXT-230-RS-W

Page 1: ...Source M HDMI Ou INSTALLATION MANUAL HDBaseT EXTENDER B 520 EXT 230 RS W...

Page 2: ...let 7 Protect the power cord from being walked on or pinched particularly at the plug end and where the power cord is attached to the apparatus 8 Only use attachments and accessories specified by the...

Page 3: ...6 2 IR Control Connections 9 6 2 1 Point to Point IR Control Stereo 3 5mm IR Receiver 10 6 2 2 Control System Mono 3 5mm IR Receiver 10 6 2 3 IR Flasher Out Mono 3 5mm 11 6 3 RS 232 Control Connection...

Page 4: ...upports all HDMI defined audio and video formats including 4K2K 30 Hz Additionally the design has been improved to solve the clock stretching issue that can arise with cable boxes when used with HDBas...

Page 5: ...justs the intensity of the IR Flasher output H DIP Switches IR RCVR PWR OFF ON OFF to connect to control system ON to connect to IR Receiver DCE DTE To select if serial RS232 communication via DB 9 is...

Page 6: ...ights up green when HDCP link has been established Blinks when content does not require HDCP Off when no HDMI signal is recognized G HDBT HPD LED Lights up green when Hot Plug event is Detected H Powe...

Page 7: ...RS 232 DB 9 from a control system if being used 6 Connect an IR control system to the IR receiver and or IR flasher if being used Refer to Section 6 2 7 Connect the 12V DC 2A power supply to the threa...

Page 8: ...nsmission path may include a maximum of two keystones and two patch cables as long as the total length does not exceed 200 for Cat 5e 6 and 230 for Cat 6a 7 Pin 1 White Orange Pin 5 White Blue Pin 2 O...

Page 9: ...re connecting to this input review this section carefully in order to match the pinouts for the device FIGURE 5 IR Connections Note Arrow direction indicates signal flow IR Receiver In 3 5 mm Mono See...

Page 10: ...o this connection as damage may occur 1 2 3 4 ON 1 ON 2 3 FIGURE 6 Point to Point IR settings 6 2 2 Control System Mono 3 5mm IR Receiver When using a control system which generates the signal through...

Page 11: ...ceiver over the category cable The transmitter may be connected to a control system and the receiver may be connected to an RS 232 controllable device 1 2 3 4 ON 1 2 3 ON A B A B RS 232 Control DB 9 S...

Page 12: ...ta Transmit 3 RxD Data Receive 5 GND 2 3 5 FIGURE 10 RS 232 Modes and Connections 6 3 2 RS 232 Operation Mode Firmware Update Operation The RS 232 connection can also be used for firmware updates in a...

Page 13: ...y connected to the HDMI out on the transmitter and or the display connected to the HDMI out on the receiver 6 5 1 Auto EDID When the EDID DIP switch is set to AUTO the lowest common EDID setting betwe...

Page 14: ...the B 520 EXT 230 RS W receiver can be supplied via a remote power source when use of the Latch Locking Power Jack is not desired The connection is a 2 conductor removable plug located on the rear of...

Page 15: ...Hz Connections Transmitter Receiver HDBaseT Link 1x RJ45 1x RJ45 HDMI 1x HDMI Type A 19 pin female 1x HDMI Type A 19 pin female IR Receiver In 1x 3 5mmMono Stereo 1x 3 5mm Mono Stereo IR Flasher Out 1...

Page 16: ...snapav com 9 WARRANTY 2 Year Limited Warranty This Binary product has a 2 Year limited warranty This warranty includes parts and labor repairs on all components found to be defective in material or w...

Reviews: