17
ATTENTION!
Always check the wear of the plastic washer, located on the endless spool, replace it when
necessary and never forget to attach it when assembling the nozzle, as working without this
item will lead to premature wear of the parts.
It is recommended to carry out preventive maintenance every 6 months, checking and
adjusting clearances, cleaning internal parts, etc. When detecting broken or weakened parts, replace
with original parts.
ATTENTION!
Never let your equipment run out of oil in the gearbox as this will cause damage to your
equipment. Always check the oil level.
It is recommended to change the oil every 6 months of use.
To check the quantity and type of oil used in each model, refer to the table in item 2.1
(Technical Data) of this manual.
When performing oil change, use Personal Protective Equipment (PPE) to prevent direct
contact with the oil, such as waterproof PVC gloves.
Follow the instructions below to change the oil in your equipment:
Disconnect the equipment from the mains;
Remove the tray and nozzle from the grinder (instructions in item 4.3). Remove the case by
removing the securing screws;
Position a container under the gear case to store the oil to be removed;
Remove the screw located under the gear case. Wait until all the oil comes out of the screw
hole.
After all the oil is removed, thread the screw with thread seal tape again;
To install the new oil, remove the plug located on top of the gearbox;
With the aid of a funnel, add the oil. Check the oil quantity for each grinder model in the table
in item 2.2 (Technical Data);
Screw the stopper with thread stopper. Reassemble the case by fastening it with the screws.