8
Initial Settings
The DPS basic settings menu allows the user to setup digital output options, change response
time, and configure the display color and pressure units. To access the basic settings menu,
press and hold the blue “SET” button for three seconds. Press the “SET” button momentarily to
step through the seven settings within the menu. When a setting is selected, the display will
alternate between the setting ID and its value. Use the “UP” and “DOWN” buttons to change a
value and press “SET” to save.
Basic Settings
Setting ID
Value
Measurement
Mode
>3s
Digital Output
1 Operating
Mode
oPS
HYS
Win
Point Set Hysteresis Window Comparator
See “Digital Output Modes” for more information.
Digital Output
1 Contact
Type
no
nc
Normally-Open Normally Closed
Digital Output
2 Operating
Mode
oFF
oPS
HYS
Win
Off Point Set Hysteresis Window
See “Digital Output Modes” for more information.
Digital Output
2 Contact
Type
no
nc
Normally-Open Normally Closed
Response
Time
2.5
25
100
…
2.5mS 25mS
100mS …
Increase response time to reduce chatter when pressure fluctuates near the setpoint.
oE1
oE1
0.0
oE2
oE2
rES