Q: Digital output repeatability is listed as +/-0.2% F.S. +/-1 one digit. What does that
mean?
Repeatability is +/-0.2% F.S. In psi mode, for example, that translates to +/- 0.29psi. However,
the DPS display is only readable to the tenths digit (0.X) after the decimal place and the DPS
must round the measured value up or down accordingly.
Actual Pressure
Measured Pressure
(+0.2% error)
Display (0.2% + 1
digit error)
100.0psi
100.29psi
100.3psi
5.00bar
5.02bar
5.02bar
Q: Why is the voltage analog output range 1-
5V? Isn’t 0-10V more common?
DPS series switches are designed to operate with an input voltage of 12 to 24VDC. If powered
by a 12VDC supply, a 10V analog output signal could be affected by variations in the supply
voltage. As such, the analog output is limited to 5V.