Part No 442503
Form No F081512A
11
Z FORCE BLOWER Owner’s Manual
TROUBLESHOOTING
Z FORCE WIRING DIAGRAM
Replace fuse with-
20 amp bus type fuse
Problem
Possible Cause
Solution
Abnormal vibration.
· Loose or out of balance impeller.
· Check impeller and replace if required.
· Debris in impeller.
· Clear debris with compressed air or a
backpack blower (see below pictures).*
· Loose engine.
· Check engine.
Engine will not start.
· Engine not in full choke position.
· Check choke position.
· Out of gasoline or bad, old gasoline.
· Check gasoline.
· Spark Plug wire disconnected.
· Connect spark plug wire.
· Gas valve off.
· Turn on gas valve.
· Dirty air cleaner.
· Clean or replace air cleaner. Contact a
qualified service person.
Engine is locked, will not pull
over.
· Engine problem.
· Contact an engine servicing dealer for
engine problems.
Exhaust elbow not rotating
· Grease on elbow
· Clean off excess grease on elbow
· Broken belt
· Replace belt
· Battery cable not connected or
Check battery connections
battery is dead
· Charge or replace battery
· Belt off of motor pulley
Put belt back on pulley
*Using compressed air, or a Backpack blower, you can
loosen or free debris easily from the impeller and housing,
debris can cause wear and tear on the machine. Note:
Always disconnect the sparkplug when servicing.