3 – OPERATION
MANUAL BOOM OPERATION
Manual retraction, rotation and lowering functions
allow the aerial work platform to be moved and
lowered during hydraulic power interruption or
failure. In each instance, refer to Figure 3-7.
The following procedures for manual retraction,
rotation and lowering require a person on the ground
to operate the manual controls and hand pump.
The hydraulic hand pump is located in the pump
compartment. In case of a power failure, the hand
pump and selected hydraulic valve settings can be
used to manually retract the Telescoping boom or
rotate the boom turntable.
To begin manual retraction or rotation, turn
Proportional Valve counterclockwise until it stops,
and insert pump handle into the pump handle fitting.
Manual Retraction
Pushing and holding the Retract button while
simultaneously actuating Hand Pump will retract the
extension boom section.
Manual Rotation
To rotate the turntable clockwise:
Push and hold
the Rotation button and simultaneously actuate
Hand Pump.
To rotate the turntable counterclockwise:
Pull the
Rotation button out and simultaneously actuate
Hand Pump.
NOTE: Return proportional valve to its original
position before lowering the lift or
resuming normal operation.
1. Hand
Pump
2. Proportional
Valve
3. Rotation
Button
4. Retract Button
Figure 3-7. Hand Pump and Controls for Manual Lift Operation
25
Summary of Contents for 45XA
Page 1: ...OPERATOR S MANUAL 45XA AERIAL WORK PLATFORMS BOOMTM ...
Page 10: ...BILJAX 45XA 8 NEVER jumpstart other vehicles using the boom lift batteries ...
Page 17: ...2 BEFORE OPERATION 15 ...
Page 31: ...3 OPERATION 29 ...
Page 37: ...4 TROUBLESHOOTING 35 ...
Page 43: ...5 DECAL PLACEMENT 41 ...
Page 46: ...BILJAX 45XA RANGE OF MOTION Figure 7 1 Range of Motion 44 ...
Page 50: ...BILJAX 45XA 48 ...
Page 51: ...NOTES ...