background image

 

2  

BIJUR DELIMON INTERNATIONAL 

BA_2018_1_GB_WSE

 

 

INDEX 
 

  1.   General  ........................................................  2 

  2.   Safety  ....................................................  2 – 3 

  3.   Application  ..................................................  4 

  4.   Design and Function  .........................  4 – 5 

  5.   Dimensions  .................................................  6 

  6.   Technical Data  ...........................................  8 

  7.   Unit configuration and coding  .............  9 

  8.   Assembly, installation and 

 commissioning  ...............................  10 - 13 

  9.   Maintenance and servicing  ................  13 

10.   Spare parts  .............................................  14 

11.   Storage and transport  ........................  14 

12.   Suitable system components  ............  14 

13.  Plates  ........................................................  14 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. GENERAL 

Prior to start up, we recommend to read 
these operating instructions carefully as we 
do not assume any liability for damages and 
operating troubles which result from the 
nonobservance of these operating 
instructions! 
The below described pump is designed for 
use in centralized lubrication systems or to 
supply downstream lubrication systems. 
Any use beyond the applications described 
in these operating instructions is 
considered to be not in accordance with the 
product’s intended purposes. The 
manufacturer is not to be held responsilbe 
for any damages resulting from this: the 
user alone bears the corresponding risk.  
As to figures and indications in these 
operating instructions we reserve the right 
to make technical changes which might 
become necessary for improvements.  
The copyright on these operating 
instructions is kept reserved to the 
company DELIMON. These operating 
instructions are intended for the erecting, 
the operating and supervising personnel. 
They contain regulations and drawings of 
technical nature which must not – 
completely or partially - be distributed nor 
used nor communicated to others without 
authorization for competition purposes. 
 
Company address, spare parts and 
service address 
DELIMON GmbH 
Arminstraße 15 
D-40277 Düsseldorf 
Phone +49 211 7774-0 
Fax +49 211 7774-210 
 
Branch office 
Am Bockwald 4 
D-08344 Grünhain-Beierfeld 
Email: [email protected] 
www.bijurdelimon.com 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

2. SAFETY 

These operating instructions contain 
fundamental instructions which are to be 
observed during erection, operation and 
maintenance. Therefore it is absolutely 
necessary for the fitter and the 
competent qualified staff/user to read  
these operating instructions before 
installation and start-up. The operating 
instructions must be available at all times 
at the place of use of the 
machine/system. 

Not only the general safety instructions 
stated under this main point “safety“ are to 
be observed, but also the other specific 
safety instructions stated under the other 
main points. 
 
2.1  Identification of safety warnings in 

 the operating instructions 

The safety warnings contained in these 
operating instructions which, if not 
observed, may cause dangers to people, are 
specially marked with general danger 
symbols 

 safety sign according to DIN 

4844, warning about a danger spot, in case 
of warning about electric voltage with 

 safety sign according to DIN 

4844, warning about dangerous electric 
voltage. 
 
In case of safety instructions which, if not 
observed, may cause damage to the 
product and its function, the word 

ATTENTION 

is inserted. 
Instructions that are directly attached to 
the machine, as for example 

 

rotational direction arrow 

 

identifications for fluid connections 

must be observed at all events and 
maintained in a fully legible condition. 

 

Note: There is an increased skid risk in 
case of spilled/leaked out lubricants. 
They are to be removed at once 
properly. 

 
 

 Safety sign according to DIN  

4844, warning about skid risk. 
 

Summary of Contents for WS-E

Page 1: ...1 BIJUR DELIMON INTERNATIONAL BA_2018_1_GB_WSE Operating manual Chain lubrication aggregate WS E BA_2018_1_GB_WSE ...

Page 2: ... spare parts and service address DELIMON GmbH Arminstraße 15 D 40277 Düsseldorf Phone 49 211 7774 0 Fax 49 211 7774 210 Branch office Am Bockwald 4 D 08344 Grünhain Beierfeld Email kontakt bijurdelimon com www bijurdelimon com 2 SAFETY These operating instructions contain fundamental instructions which are to be observed during erection operation and maintenance Therefore it is absolutely necessar...

Page 3: ...on and installation work The user has to take care that all the maintenance inspection and installation work is executed by authorized and qualified skilled personnel who have informed themselves adequately by thoroughly studying the operating instructions Basically work on the machine is only to be carried out during shut down It is obligatory to observe the shut down procedure described in the o...

Page 4: ...namic dividers of type ZE E and when connected in this way the unit allows for the targeted and metered lubrication of moving lubrication points by means of a flying drop up to 7 drops per second depending on the viscosity Another possible application consists of use with static single line dividers or use as a delivery pump in connection with a solenoid valve at the end of the main line 4 STRUCTU...

Page 5: ...ction of the outlet and if the unit is being used in the WS E system then the oil can serve the following ZE E dividers These then deliver their pre stored quantity of lubricant to the lubrication points at high speed via the spray nozzles in the form of a targeted drop Interrupting the power supply to the solenoid valve causes the valve to be mechanically switched back to its starting position Th...

Page 6: ...6 BIJUR DELIMON INTERNATIONAL BA_2018_1_GB_WSE 5 DIMENSIONS mm WS E 4 litre WS E 12 litre ...

Page 7: ...hree phase motor art no 769115213 3 PE AC 50Hz 400V 0 18kW 3000 rpm UL alternating current motor art no 76911M293 1 N PE AC 60Hz 115V 0 18kW 3600 rpm UL three phase motor art no 76911M090 3 PE AC 60Hz 115V 0 18 kW 3600 rpm Technical specifications of the solenoid valve see appendix for datasheets Solenoid valve art no 38152M129 DC 24V 24W Solenoid valve art no 381521133 1 N PE AC 50Hz 230V 19VA Te...

Page 8: ...8 BIJUR DELIMON INTERNATIONAL BA_2018_1_GB_WSE 6 TECHNICAL DATA Wiring diagram for terminal box 76922 7743 Connection dimensions 113 mm x 52 mm Central drilled holes with bottom of housing ...

Page 9: ... alternating current motor 115V 60Hz 15 UL three phase motor 115V 60Hz 12 Cycle valve Direct current DC 24V 24 Alternating current AC 230V 23 Accessories None 00 Float switch for 4 litre 2x min 12 48V 01 Float switch for 4 litre 2x min 250V 02 Float switch for 12 litre 1x min 250V 03 Terminal box 12 litre version only 04 Automotive system PSA with filling via sealing nipple for 4 litre version 05 ...

Page 10: ...o The unit must be mounted tension free onto a flat surface Positioning the pump unit When installing the pump unit it must be ensured that it is positioned as closely and centrally as possible to the connected lubrication points In connection with the ZE E lubricant divider it must also be ensures that the distance between the pump unit and the furthest ZE E divider does not exceed 5 m o The pump...

Page 11: ... rotation direction is correct when the power supply is turned on Arrow on the motor o The oil is circulated via the opened solenoid valve in a de pressurised state o Remove the plug on the solenoid valve in order to prevent pulsing during the adjustment phase Solenoid valve ...

Page 12: ... least a steady flow of drops The individual dividers will deliver the oil on a staggered basis If not all of the dividers worked the first time no visible functioning then the procedure must be repeated by turning the throttle screw anti clockwise all the way back against the locking screw and then closing it again by slowly turning in a clockwise direction The dividers will not start working at ...

Page 13: ...is leak tight and is working perfectly at each installed divider and lubrication point Continuous operation The pump unit is designed for continuous operation It must be ensured that the specified operating pressure and temperature range are complied with during the entire operating phase Only ever use approved lubricant that is free from any contamination Disassembly The pump unit must only be di...

Page 14: ...re tank WSEETA0006 Spare parts kit 14 litre gear wheel pump with tank cover 11 STORAGE AND TRANSPORT The unit should ideally be stored and transported vertically in order to ensure that it is not contaminated by lubricant residues in the tank Other than that there are no other particular transport or storage regulations 12 SUITABLE SYSTEM COMPONENTS The following distributor types are primarily us...