Check whether the motor rotation direction is correct when the power supply is turned on. (Arrow on the motor) 

 

 

 

 

 

 

 

 

 

 

 

o

 

The oil is circulated via the opened solenoid valve (in a de-pressurised state). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

o

 

Remove the plug on the solenoid valve in order to prevent pulsing during the adjustment phase. 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Solenoid valve 

Summary of Contents for WS-E

Page 1: ...1 BIJUR DELIMON INTERNATIONAL BA_2018_1_GB_WSE Operating manual Chain lubrication aggregate WS E BA_2018_1_GB_WSE ...

Page 2: ... spare parts and service address DELIMON GmbH Arminstraße 15 D 40277 Düsseldorf Phone 49 211 7774 0 Fax 49 211 7774 210 Branch office Am Bockwald 4 D 08344 Grünhain Beierfeld Email kontakt bijurdelimon com www bijurdelimon com 2 SAFETY These operating instructions contain fundamental instructions which are to be observed during erection operation and maintenance Therefore it is absolutely necessar...

Page 3: ...on and installation work The user has to take care that all the maintenance inspection and installation work is executed by authorized and qualified skilled personnel who have informed themselves adequately by thoroughly studying the operating instructions Basically work on the machine is only to be carried out during shut down It is obligatory to observe the shut down procedure described in the o...

Page 4: ...namic dividers of type ZE E and when connected in this way the unit allows for the targeted and metered lubrication of moving lubrication points by means of a flying drop up to 7 drops per second depending on the viscosity Another possible application consists of use with static single line dividers or use as a delivery pump in connection with a solenoid valve at the end of the main line 4 STRUCTU...

Page 5: ...ction of the outlet and if the unit is being used in the WS E system then the oil can serve the following ZE E dividers These then deliver their pre stored quantity of lubricant to the lubrication points at high speed via the spray nozzles in the form of a targeted drop Interrupting the power supply to the solenoid valve causes the valve to be mechanically switched back to its starting position Th...

Page 6: ...6 BIJUR DELIMON INTERNATIONAL BA_2018_1_GB_WSE 5 DIMENSIONS mm WS E 4 litre WS E 12 litre ...

Page 7: ...hree phase motor art no 769115213 3 PE AC 50Hz 400V 0 18kW 3000 rpm UL alternating current motor art no 76911M293 1 N PE AC 60Hz 115V 0 18kW 3600 rpm UL three phase motor art no 76911M090 3 PE AC 60Hz 115V 0 18 kW 3600 rpm Technical specifications of the solenoid valve see appendix for datasheets Solenoid valve art no 38152M129 DC 24V 24W Solenoid valve art no 381521133 1 N PE AC 50Hz 230V 19VA Te...

Page 8: ...8 BIJUR DELIMON INTERNATIONAL BA_2018_1_GB_WSE 6 TECHNICAL DATA Wiring diagram for terminal box 76922 7743 Connection dimensions 113 mm x 52 mm Central drilled holes with bottom of housing ...

Page 9: ... alternating current motor 115V 60Hz 15 UL three phase motor 115V 60Hz 12 Cycle valve Direct current DC 24V 24 Alternating current AC 230V 23 Accessories None 00 Float switch for 4 litre 2x min 12 48V 01 Float switch for 4 litre 2x min 250V 02 Float switch for 12 litre 1x min 250V 03 Terminal box 12 litre version only 04 Automotive system PSA with filling via sealing nipple for 4 litre version 05 ...

Page 10: ...o The unit must be mounted tension free onto a flat surface Positioning the pump unit When installing the pump unit it must be ensured that it is positioned as closely and centrally as possible to the connected lubrication points In connection with the ZE E lubricant divider it must also be ensures that the distance between the pump unit and the furthest ZE E divider does not exceed 5 m o The pump...

Page 11: ... rotation direction is correct when the power supply is turned on Arrow on the motor o The oil is circulated via the opened solenoid valve in a de pressurised state o Remove the plug on the solenoid valve in order to prevent pulsing during the adjustment phase Solenoid valve ...

Page 12: ... least a steady flow of drops The individual dividers will deliver the oil on a staggered basis If not all of the dividers worked the first time no visible functioning then the procedure must be repeated by turning the throttle screw anti clockwise all the way back against the locking screw and then closing it again by slowly turning in a clockwise direction The dividers will not start working at ...

Page 13: ...is leak tight and is working perfectly at each installed divider and lubrication point Continuous operation The pump unit is designed for continuous operation It must be ensured that the specified operating pressure and temperature range are complied with during the entire operating phase Only ever use approved lubricant that is free from any contamination Disassembly The pump unit must only be di...

Page 14: ...re tank WSEETA0006 Spare parts kit 14 litre gear wheel pump with tank cover 11 STORAGE AND TRANSPORT The unit should ideally be stored and transported vertically in order to ensure that it is not contaminated by lubricant residues in the tank Other than that there are no other particular transport or storage regulations 12 SUITABLE SYSTEM COMPONENTS The following distributor types are primarily us...