background image

BIJUR DELIMON INTERNATIONAL

(919) 465 4448 

LOCAL   

(800) 631 0168 

TOLL-FREE   

(919) 465 0516 

FAX   

WWW.BIJURDELIMON.COM

2100 Gateway Centre Blvd., Suite 109
Morrisville, NC 27560

35994  •  R2 

08/15

2

Typical Layout

See drawing below for typical layout with all the recommended accessories for the pump to operate 
correctly. The compressed air supply must be fi xed between 40 and 140 psi (3 and 10 bar). The 
recommended pressure is 90 psi (6 bar). An air shut-off valve must be installed to be able to close 
the compressed air line at the end of the day (if the air inlet is not closed and there is leakage in 
some point of the grease outlet circuit, the pump will start automatically, emptying the container).

Item

Description

A

Air shut-off valve (LP)

B

Filter regulator

C

2’ air hose

D

Quick coupling

E

Connection nipple

F

55:1 Pump

G

5’ grease hose

H

Grease shut-off valve (HP)

I

Cover (400 lb drum)

J

Follower plate

0

8

9

1

2

 \\

 $\\

3

4

5

6

7

Summary of Contents for DP33

Page 1: ...automatically when the outlet valve is opened Note It is important that the lower valve does not come into contact with contaminated surfaces such as a workshop floor as it may become contaminated with dirt or foreign particles that can damage the pump mechanism Technical Data Maximum Air Pressure 140 psi 10 bar Minimum Air Pressure 40 psi 3 bar Maximum Delivery 100 psi 2 6 lb 1200 gr min Air Inle...

Page 2: ...en 40 and 140 psi 3 and 10 bar The recommended pressure is 90 psi 6 bar An air shut off valve must be installed to be able to close the compressed air line at the end of the day if the air inlet is not closed and there is leakage in some point of the grease outlet circuit the pump will start automatically emptying the container Item Description A Air shut off valve LP B Filter regulator C 2 air ho...

Page 3: ...he cover 2 Unthread the nut 3 and remove the washer 4 the guide ring 5 and the air escape ring 11 with their O rings and the washers 10 2 Unthread the screws 20 and remove the inverter head 17 3 Unthread the inverter rod 24 and remove the O rings 6 4 Unthread the screws 37 remove the air cylinder 28 and take out the piston assembly 25 32 and 40 5 Replace the damaged parts and assemble following pr...

Page 4: ...mpact the grease The pump begins to operate very fast The drum is empty or the grease level is beneath the suction tube inlet Replace the drum or lower the suction tube until the inlet reaches below the grease level The pump runs on continuously after the grease outlet is closed There is a grease leak in some point of the outlet circuit Verify and tighten or repair Grease is leaking through the ou...

Page 5: ... COM 2100 Gateway Centre Blvd Suite 109 Morrisville NC 27560 35994 R2 08 15 5 See page 6 for diagram 1 2 3 4 5 6 11 12 6 7 18 19 22 23 21 8 9 17 6 10 20 4 16 24 10 6 25 26 6 27 26 6 28 15 14 13 29 44 54 45 46 47 48 49 48 34 50 51 52 53 30 31 32 35 33 34 37 36 26 43 38 4 39 40 41 42 Service Parts Diagram ...

Page 6: ...valve kit F740976 34 45 52 Seal kit F740975 26 34 36 42 Mufflers air filters kit F740977 13 14 18 See parts list on page 5 Service Parts Item Description Part 13 Circlip F942728 14 Muffler F835400 41 Outlet valve F740631 44 Pump tube for part F334 F740637 Pump tube for part F332 F740638 43 Connection rod for part F334 F840459 Connection rod for part F332 F840460 54 Bung adapter F410002 Reversing m...

Page 7: ...OLL FREE 919 465 0516 FAX WWW BIJURDELIMON COM 2100 Gateway Centre Blvd Suite 109 Morrisville NC 27560 35994 R2 08 15 7 Dimensional Schematics Part A B F332 1010mm 39 7 730mm 28 7 F334 1215mm 47 8 925mm 36 4 0 1 ß 08A 8 6A40B4 DC Measurements shown in millimeters ...

Reviews: