background image

BIJUR DELIMON INTERNATIONAL

(919) 465 4448 

LOCAL   

(800) 631 0168 

TOLL-FREE   

(919) 465 0516 

FAX   

WWW.BIJURDELIMON.COM

2100 Gateway Centre Blvd., Suite 109   
Morrisville, NC 27560

35994  •  R2 

08/15

4

Clean or Replace the Upper Valve

1.  Unthread and remove the foot valve tube (61) from the pump tube (50) and take out the 

connection rod (52) together with the high pressure piston (56).

2.  Gently push out the packing assembly (57-60) from the pump tube (50) using a ø19mm tube and 

clean it carefully, replace any if damaged.

3.  Remove the pin that holds the connection rod (52) to the high pressure piston (56) and unthread 

the piston. Take out the components of the upper valve (53-55) and clean them carefully, replace 
any if damaged.

4.  Assemble the pump following the previous instructions, reversing each step.

Troubleshooting

Symptom

Possible Cause

Remedy

The pump is not working or 
there is no grease delivery.

Not enough air supply pressure.

Slowly increase the air supply 
pressure.

Some outlet line component is clogged or 
closed.

Clean or open the outlet circuit.

There are air pockets in the grease inlet 
area.

Stir and compact the grease.

The pump begins to operate very fast.

The drum is empty or the grease level is 
beneath the suction tube inlet.

Replace the drum or lower the 
suction tube until the inlet reaches 
below the grease level.

The pump runs on continuously 
after the grease outlet is closed.

There is a grease leak in some point of 
the outlet circuit.

Verify and tighten or repair.

Grease is leaking through the 
outlet muffl er.

Grease has by-passed to the air motor 
caused by worn or damaged packing set.

Replace the worn or damaged parts.

Air is leaking through the 
outlet muffl er.

The O-rings of the distributor axle (21) or 
the bushings (16) are worn or damaged.

Replace the axle assembly (21) and/
or bushing assembly (16).

The inverter O-rings are worn 
or damaged.

Replace the inverter O-rings.

Decrease of the grease delivery.

Dirt in upper valve or the foot valve.

Dismount and clean, replace 
if damaged.

Dirt in muffl er (18).

Dismount and clean/replace muffl er.

How to Order

Description

Drum Size

Part #

DP33 Pump

120 lb

F332

400 lb

F334

When ordering, specify by name, description and part number, e.g. DP33 Pump, 120 lb Drum, 
Part #F332.

  

Refer to page 5 for parts reference.

Before starting any kind of maintenance 
or repair, disconnect the compressed air 
supply and open a downstream valve to 
relieve the grease pressure. 

Summary of Contents for DP33

Page 1: ...automatically when the outlet valve is opened Note It is important that the lower valve does not come into contact with contaminated surfaces such as a workshop floor as it may become contaminated with dirt or foreign particles that can damage the pump mechanism Technical Data Maximum Air Pressure 140 psi 10 bar Minimum Air Pressure 40 psi 3 bar Maximum Delivery 100 psi 2 6 lb 1200 gr min Air Inle...

Page 2: ...en 40 and 140 psi 3 and 10 bar The recommended pressure is 90 psi 6 bar An air shut off valve must be installed to be able to close the compressed air line at the end of the day if the air inlet is not closed and there is leakage in some point of the grease outlet circuit the pump will start automatically emptying the container Item Description A Air shut off valve LP B Filter regulator C 2 air ho...

Page 3: ...he cover 2 Unthread the nut 3 and remove the washer 4 the guide ring 5 and the air escape ring 11 with their O rings and the washers 10 2 Unthread the screws 20 and remove the inverter head 17 3 Unthread the inverter rod 24 and remove the O rings 6 4 Unthread the screws 37 remove the air cylinder 28 and take out the piston assembly 25 32 and 40 5 Replace the damaged parts and assemble following pr...

Page 4: ...mpact the grease The pump begins to operate very fast The drum is empty or the grease level is beneath the suction tube inlet Replace the drum or lower the suction tube until the inlet reaches below the grease level The pump runs on continuously after the grease outlet is closed There is a grease leak in some point of the outlet circuit Verify and tighten or repair Grease is leaking through the ou...

Page 5: ... COM 2100 Gateway Centre Blvd Suite 109 Morrisville NC 27560 35994 R2 08 15 5 See page 6 for diagram 1 2 3 4 5 6 11 12 6 7 18 19 22 23 21 8 9 17 6 10 20 4 16 24 10 6 25 26 6 27 26 6 28 15 14 13 29 44 54 45 46 47 48 49 48 34 50 51 52 53 30 31 32 35 33 34 37 36 26 43 38 4 39 40 41 42 Service Parts Diagram ...

Page 6: ...valve kit F740976 34 45 52 Seal kit F740975 26 34 36 42 Mufflers air filters kit F740977 13 14 18 See parts list on page 5 Service Parts Item Description Part 13 Circlip F942728 14 Muffler F835400 41 Outlet valve F740631 44 Pump tube for part F334 F740637 Pump tube for part F332 F740638 43 Connection rod for part F334 F840459 Connection rod for part F332 F840460 54 Bung adapter F410002 Reversing m...

Page 7: ...OLL FREE 919 465 0516 FAX WWW BIJURDELIMON COM 2100 Gateway Centre Blvd Suite 109 Morrisville NC 27560 35994 R2 08 15 7 Dimensional Schematics Part A B F332 1010mm 39 7 730mm 28 7 F334 1215mm 47 8 925mm 36 4 0 1 ß 08A 8 6A40B4 DC Measurements shown in millimeters ...

Reviews: