background image

Basic Alarm Setting

Tone setting

Tone setting means the alarm system will make “beep” sound, when 
detects system event, such as telephone line cut, Arm/Disarm, 
Temperature Alert.

Siren Setting
Tone Setting

Arm/Disarm Tone
Off                         >

Arm/Disarm Beep
Off                         >

Push “

◀▶

” to choose “OK” to save

Call in Setting

The system can receive the phone call via GSM. It allow user to set the 
ring times from 1 to 9. When the ring time reach to preset times, it will 
pick up the phone call for remotely control

Call in Setting
Program&Delete

GSM Call in Tone
                              3

Push “     ” to delete exist data. It accpets ring time between 1-9. Push 
“OK” to save.

Program&Delete

Use this function to program/delete wireless sensors and accessories 
(remote keyfob,wireless LED/LCD keypad). The wireless zone number is 
from 00-30. Zone 00 is for programming wireless remote keyfob or 
leypads.

Basic Alarm Setting

Call in Setting
Program&Delete

Zone No
           00

Program
Delete

Success

Push “      ” to delete the zone number, and input new zone number from 
00-30 and push “OK”. push “

 

” to choose [program], then push “OK”, 

the LCD will display [programming]. Trigger the wireless sensors for two 
times, the LCD display [Success], push “OK” to save, you can continue to 
enroll more sensors.
Push “       ” to delete the zone number, and input new zone number from 
00-30 and push “OK”. push “

 

” to choose delete, the LCD will display 

[Success], push”OK” to save. This will erase the current sensors in the zone 
from the alarm system. 

Zone Attribute

The system has advanced zone attribute, it allow user to choose each of 
attribute for the zones, it helps user to customize the system, which can 
be more suitable fot speciÞc installation. Ensuring the zones with correct 
attribute, therefore sensors can work properly.

Zone No
           00

Zone Attribute
Upload

Activate                >
0 Defence Line     >

00Help                  >
Alarm Delay Off    >

Zone Chime Off    >
Smart Sensor Off  >

7

Summary of Contents for BE-X9

Page 1: ...WiFi GSM RFID Smart Alarm System User Manual When designing this system be added many amazing practical new features to make sure a better smart life...

Page 2: ...rt ADEMCO Contact ID Protocol It can work with CMS Central Monitor System 9 Delay Alarm External Internal siren On Off for any zone 10 Low voltage sensor sensor lost be monitored 11 RFID tag to Arm Di...

Page 3: ...sists of Wireless Wide Angle Motion Sensor 24 Hours Defend Line 24 Hour zones This attribute can not be modi ed In arm or disarm or stay mode once the sensor in these zones be triggered system will al...

Page 4: ...el View ON OFF BELL 34 33 32 31 12V S GND A NO COM J12 S3 Button Cable Slot WiFi SET Recovery SIM Card Slot Wired Connection Wired Siren I O connector Button 12V output A Arm disarm S SMS DC 12V input...

Page 5: ...he system is working with separate wireless LCD LED keypads for activate and deactive operation please refer to manual of wireless keypad Arm Disarm System Basic Alarm Setting Enter into Setting Statu...

Page 6: ...eceiving SMS report of system s status including AC power recover Arm Disarm Host Low Voltage Sensor Low Voltage SMS Setting Record SMS Phone No 13800138000 AC Power Recover OFF Arm Disarm SMS OFF Hos...

Page 7: ...em set alarm off This allow user enter into specific detection area to disarm the system without triggering alarm Basic Alarm Setting Arm Delay Alarm delay Alarm Delay 10 Push to delete exist data and...

Page 8: ...remote keyfob or leypads Basic Alarm Setting Call in Setting Program Delete Zone No 00 Program Delete Success Push to delete the zone number and input new zone number from 00 30 and push OK push to ch...

Page 9: ...se smart sensor off push to enable or disable this function Notice 0 Defense line means re panic alarms which are belong to 24 hours emergency zone It will trigger the alarm system even the system in...

Page 10: ...ration Moreover the system not only upload alarm information but also upload system s status to central monitoring station Zone Attribute Center Phone No User Code Upload status Upload 911 0001 Off Pu...

Page 11: ...rm Disarm This function can make the alarm system automatically Arm Disarm in preset time for everyday Reset Auto Arm Disarm SUN Away Arm push to delete the default time and input new time e g 1200 pu...

Page 12: ...rn off No 2 switch Press host keyfob 21 turn on 20 turn off User Password P31 means turn on No 3 switch User Password P30 means turn off No 3 switch Press host keyfob 31 turn on 30 turn off User Passw...

Page 13: ...r alarm SMS notification The system will send SMS with below content 0001 Alarm System 11 Zone Door Sensor Alarming Inquiry System s Status The system allow user to inquiry the system s status send Us...

Page 14: ...ss 1 on the phone to Away Arm lt will hang up immediately system will be Away Armed Press 2 on the phone to Stay Arm lt will hang up immediately system will be Stay Armed Press 3 on the phone to Disar...

Page 15: ...amming Now press the button for two times the LCD will display Success then touch OK to save Arm Disarm SOS Away Arm the system Stay Arm the system Disarm the system Trigger SOS alarm Press to choose...

Page 16: ...ystem RF transmitter Panic button Magnetic LED lndicator Tamper Swtich Battery Notice The door sensor in the package may differ from manual Press to choose Delete then press OK to confirm the LCD will...

Page 17: ...and the magnet with dou ble sided tape or the screw Avoid placing the detector in areas with la rge metallic structu res or electrical installations such as boiler area or counters Technical lnformati...

Page 18: ...o save How to Use Wireless PIR Sensor Introduction PIR motion sensor is one of common intrusion sensor for instruction detection It with advantages of large space protection lowest ener 9V consumption...

Page 19: ...Wall mounted on corridor to detect movement Notice The PIR sensor in the package may different from manual The specification will change when use different model of wireless PIR sensor Technical Info...

Page 20: ...anel and any wireless sensars in too cold too hot or dusty places to prevent it from curtailing the service lives of electric parts and preventing the plastic shell from distorting Do not put the alar...

Page 21: ...APP Operation Instructions 20...

Page 22: ...21...

Page 23: ...22...

Page 24: ...23...

Page 25: ...24...

Page 26: ...25...

Page 27: ...26...

Page 28: ...27...

Page 29: ...28...

Page 30: ...29...

Page 31: ...30...

Page 32: ...31...

Page 33: ...32...

Page 34: ...33...

Reviews: