December 2020
Installation, Operation and Maintenance Manual
MAN 606 Rev. 5
Operation and Use
d
c2
c1
g
c1
d
v
c2
22
Section 3: Operation and Use
Hydraulic cylinder size
Wrench c1 (mm)
Wrench c2 (mm)
14
17
60
18
17
60
32
17
60
50
17
60
For the adjustment of the mechanical stop screwed into the left side of housing, follow
these steps (Figure 20 and Figure 21):
•
Loosen the locknut (d) with the specific wrench (c2).
•
Adjust the pin (g)/screw (v) with the adequate wrench (c1).
•
Turn counterclockwise to increase the angular stroke, turn clockwise to decrease it.
•
When the adjustment is over tighten the locknut (d).
Hydraulic cylinder size
Wrench c1 (mm)
Wrench c2 (mm)
0,3
30
30
0,9
30
30
1,5
41
41
3
41
41
6
46
46
Table 7.
Table 8.
Mechanical stop on the housing
Figure 20
Mechanical stop on the housing
Figure 21
Mechanical stop on the housing