3
Installation, Operation and Maintenance Manual
MAN 564 Rev. 6
June 2020
General Warnings
Section 1: General Warnings
1.4
Data Sheet
Supply fluid
Air, nitrogen or sweet gas, special version available for sour gas
Operating temperature
Standard: from –30 °C to +100 °C
Optional: from –60 °C to +200 °C
Supply pressure
Please refer to technical document: “actuator data sheet”
Output torque
Up to 750000 Nm (higher value with special version)
Manual handpump - MHP
(optional)
Control system (optional)
Valve coupling
Pneumatic
cylinder
Valve position indicator
Scotch yoke mechanism
Hydraulic cylinder for ALGA-MHP models
or second pneumatic cylinder for ALGA*2
double cylinder models (optional)
Figure 2
Identification of actuator parts