M
ANUAL
I
NSTALLATION
Version: 6.1 (05-12-2011)
21
-
Remove the bracket
2
from the unit and the box.
-
Install the box on the wall at an appropriate point.
Caution:
c
Do not
disconnect the wiring between the box and the
unit.
3
4
3. Lay the control cable(s) into the box, through the free
cable gland(s)
3
.
4. Connect the controller of the system to the terminal block
4
:
-
Connect the control cable of the outdoor unit to F1/
F2.
-
If installed on your unit:
Connect the Daikin control
panel to P1/P2.
5. Tighten the cable gland(s).
6. Install cover
1
on the box again.
2.6.3 Connection of cooling medium
•
Install the lines according to the installation manual of the
Daikin outdoor unit.
•
Solder the lines to the pipes protruding out of the upper
side of the unit.
2.6.4 Settings on the Daikin control panel
You can make local settings on the Daikin control panel as
described in the corresponding installation manual.
The units described in this manual have a few additional setting
possibilities:
.
M
ODE
NUMBER
F
IRST
CODE
NUMBER
D
ESCRIPTION
OF
THE
SETTING
S
ECOND
CODE
NUMBER
01
02
03
04
(22)
3
Function of air
curtain when
not heating
(23)
8
Function of air
curtain in
defrost mode
(standard
setting)
unheated
(standard
setting)
unheated
at
standstill
(if 23-8 is
set to 01)
--
at
standstill
unheated
unheated
--